Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹21.9 L+₹1.1 L (5.25%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹23.5 L+₹2.7 L (12.8%)Rejected-AOC | L3 | Rejected-AOC ok |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Oct 2021, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF LT EXTERNAL ELECTRIFICATION AND ALL CONNECTED WORKS AT 23 (I) R AND O FLIGHT UNDER GE (W) BAREILLY
2021_MES_477310_1
8997/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹50,000
Yes
8 Nov 2021
23 Sept 2021
27 Oct 2021
23 Sept 2021
25 Oct 2021
11 Oct 2021
23 Sept 2021 - 9 Oct 2021
Amount
Periodical maintenance of complete runway lighting system and repair by dismantling of air field/taxi track light fitting, AFL Cable & Connection of any description and segregatting to servicable and unserviceable parts and make it in serviceable condition by deploying person who have knowledge about Air field light system, Constant current regulator and Beacon light compelte all as specified and directed. Note (i) Replacement of spare parts will be measure and paid separately under respective item of schedule. (ii) T&P and HT insulation tape required for repair will be arrange by the contractor with his own cost. (iii) Day of maintanence/ repairs intimate by the Dept prior to flying twice in a month. (iv) Failed to maintaining Runway light system for flying will be penalty of Rs 2000/- borne per job by the contractor.
S&F bipin halogen lamp 200 watt 6.6 Amp 50 HZ all as directed by Engr In Charge.
S&F bipin halogen lamp 45 watt 6.6 Amp 50 HZ all as directed by Engr In Charge.
S&F Bipin halogen holder for 200/45 watt lamps complete with chord complete all as specified and directed
S&F isolating transformer 200W, 6.6 Amp, 50 HZ all as directed by Engr In Charge. Make- Bildal
S&F isolating transformer 45W, 6.6 Amp, 50 HZ all as directed by Engr In Charge.
S&F Protection Glass cover with washer for 200 watt runway light (Clear white) complete all as specified and directed.
S & F Protection Glass cover with washer for 45 watt Taxi track light (Blue) complete all as specified and directed.
S&F 6 Sqmm AFL cable connector (male female joint kit) complete all as specified and directed.
S&F in repair Run way light fitting 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
S&F in repair Taxi way light fittings 45 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
M&L for servicing, Oiling, greasing and testing of Beacon lights including replacement of unsv spares as required complete all as specified and directed.
S&F in repiar LED aviation obstruction light 12 Watt with fitting complete and making electric connections.Note :- Obstruction lights are to be replaced/fixed at Hangers/ATC
S&F in replacement light fitting JETAIRIS Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 150 W. Make : Havells, C&S or equivalent
All as per Item Ser No 15 but rectangular flood light LED 120W.
S& F in replacement LED Bollard light 8 watt in cylindrical shape with opal acrylic diffuser and IP65 protection, complete all as specified and as directed.
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW3P, three phase, max load 12KW or equivalent of other make complete all as specified and directed.
S&F in repair decorative LED post top lanterns with diffuser and painted spun aluminium deflector 40/35 watt LED fitting with IP66 protection fixing the fitting on steel pole/brick pillar and making good the disturbed surfaces complete all as specified and as directed.
S&F in replacement PVC insulated and PVC round sheathed, aluminum conductor (flexible) industrial cable, 2.5 Sqmm 2 core, 1100 volts complete all as specified and as directed
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
All as per srl item 24 here-in-before but using old bricks obtained under excavation
Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables, bricks and store for relaying complete all as specified & directed. Note : Excavation and earth work will be paid and measured sepertely in relevant item.
Supply and laying in replacement of OH ACSR Conductor / XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 185 Sqmm 3.5 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 27 here-in-before but 95 Sq mm 3.5 core
All as per Ser item No 27 here-in-before but 35 Sq mm 3.5 core
All as per Ser item No 27 here-in-before but 25 Sq mm 4 core
All as per Ser item No 27 here-in-before but 16 Sq mm 4 core
S&F in replacement HT tropodome PVC insulated sheathed, AFL cable 6.6 Amps 5000 volts, with copper conductor 6 sqmm single core mltistranded including taking out of old cables complete all as specified and directed.
M&L in repair for boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50mm bore for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
M&L in repair for MS Cage for protection for Run way light and Taxi light, made out from steel framed bracket, nosing to steps including embeding in concrete and screwing etc. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire,wire mesh etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165, as per sample complete all as specified and directed.
M&L Scraping of old paint from the steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative White and Red strips of 30 cm each upto 1.5 mtr height using synthetic enamel paint including numbering of pole by lettring height 40mm of black paint on 180mm black bordered luminious yellow circle. Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of synthetic enamel aluminium paint all as required at site or directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / street light poles upto 3 mtr from furthest conductor / pole including removing of cut branches and cleaning of site complete all as specified and directed. Note:- (a) Tools & plants including safety measures equipments like belt, ladder & ropes etc shall be arranged by the contractor at own cost. (b) Contractor supervisor will take proper shut down before starting the work and clear it before resuming power supply, however full assistance will be provided by MES Staff.
M&L in repair Earthing complete with galvanized steel plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead GI strip 32x6mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire/lead on DG set/ LT panel board. all as specified and testing on completion, including provision of earth wire protected by 15 mm dia GI light grade protection pipe from test point to main board and 40mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.
Dismantling of LT PCC/steel tubular pole incl coping, foundation etc and serviceable insulators from poles for reuse and shifting of poles to E/M yard or any other location complete all as specified and as directed
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles complete all as specified and as directed. Make : Bansal/Jindal/National tube. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete including rendering complete all as specified and directed.
S&F in replacement new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver of following capacity including taking down old LED and necessary connections with 2.5 sqmm aluminum wire complete all as specified and as directed (a) 60 Watt Make: Eveready/Polycab/Compaq
(b) 72 Watt
S&F in repair loop-in-loop out box of size 30x20x20cm made out from 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos aluminium bus bar of size 25mm x 2mm-4 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts,bolts & washers etc complete all as specified and directed
Re-stretching of existing ACSR conductor and earth wire including cradles of any description any size and shape and in new position as in LT over head lines, on existing poles including opening of connections and binding wires, Restringing and tightening of conductors/earth wires in position, removing sag, binding to insulators with new aluminium wires, making and connecting jumpers connections etc including commsiiioning and testing complete all as specified and directed. The quoted rates, shall deemed to be included the following provisions also :- (a) Seting/adjusting etc in position of cradles (b) Adjusting and tightning of stay assembly wherever required (c) The above work includes trimming/cutting of all trees barnches upto 03M distance from nearest conductors/earth wire as directed at site. Note: one RM length will be measured for 03 phase and one neutral one street light and one earth wire.
Supply and fix in repair shackle type insulator, porcelain, white brown, or green insulator of size 100x115mm (Height 100 mm and 115 mm dia) with section strip 31/5 mm and 14 mm bolt complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular PVC insulated aluminium stranded conductor of size 6 sqmm served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. Make : Havells/ Polycab/Richa.
All as per Item Ser No 49 here-in-before but of size 10 sqmm
S&F in repair Approach light fittings 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
S&F in repair bulk head fittings for landing T with 100W warm white lamp, holder with glass top cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 volt 50 Hz complete all as specified and directed.
S&F in repair MCCB 415 Volts 4 pole 400 Amps 50 Hz 36 KA alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed. Make : L&T/Legrand /Havels/C&S. Note :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
All as per Item Ser No 53 here-in-before but of MCCB 250 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 53 here-in-before but of MCCB 200 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 53 here-in-before but of MCCB 125 Amps 4 pole 50 Hz 415 V, 16 KA
All as per Item Ser No 53 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 16 KA
S&F in replacement Isolator 4 pole 100 Amps, 415 Volts complete all as specified and directed.
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 04 Pole, 36 KA incl making connection /thimbles complete all as sepcified and directed
S&F Circular type CI Box of size 330 mm dia and 450 mm height for runway lights as required as per site conditions complete all as specified and directed. Make : AMA/METRO
M & L Scraping of old paint from MS protection cage of runway light and taxi light, preparation of surfaces for repairing and repainting the cage by applying two coat of synthetic enamel aluminium paint all as required at site or directed.
Note : (i) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor. (ii) A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge.
LEEJA ENTERPRISES
NOORI ENTERPRISSES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .