| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC INDEX NO D 01 HQ CE SC PUNE SHOP NO 06 FIRST FLOOR OPP CHAMUNDA HOTEL AT BOKHIRA DIST PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹41.8 L Quoted ₹42.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹43.2 L+₹44,615 (1.04%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹43.2 L+₹44,615 (1.04%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹45.1 L+₹2.4 L (5.64%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹45.1 L+₹2.4 L (5.64%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹48.1 L+₹5.4 L (12.7%)Rejected-Finance HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | ₹48.1 L+₹5.4 L (12.7%) | L4 | Rejected-Finance Being L4 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jan 2024, 6:00 pmClosed
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
ADDN ALTN TO MI ROOM P 26 AND WEATHER PROOFING TILING IN BLDG No P 62 P 63 AT CGDHQ 15 UNDER GE I CG PORBANDAR
2023_MES_630767_1
8953/E8
Open Tender
Civil Works
Item Rate
180 days
OKHA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹80,000
Yes
26 Feb 2024
2 Dec 2023
4 Jan 2024
2 Dec 2023
2 Jan 2024
19 Dec 2023
Amount
SCHEDULE 'A' B/R ITEMS
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each but with shutters (without taking off shutters from the frames), complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing tiles and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing from the site, complete all as specified and directed by Engineer-in-Charge.
Taking down existing roof treatment with carefully and disposed to out side of defence area, complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete flooor by picking, sweeping clean and washing down with water to remove dust etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick external surfaces on brick/concrete in Cement Mortar 1:4 finished even and smooth without using extra cement with WPC 2% by wt of cement, complete all as specified and directed by Engineer-in-Charge. Note:-WPC measured and paid separatly
Supply only integral water proofing compound, complete all as specified and directed by Engineer-in-Charge.
Material & Labour applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2kg/m2 incl cleaning surface, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for APP Based Polymeric memberane minimum weighing 3 kg /sqm and minimum 3mm thick Reinforced with polyster non wove fabric (wt not less than 150 gms/ sqm) laid on primed surface by forced application, complete all as specified and directed by Engineer-in-Charge.
Material & Labour applying two coats of bituminous aluminium paint on APP membrane of any description laid on roof slabs, complete all as specified and directed by Engineer-in-Charge.
Taking up or down 25 or 32 mm steel tubing and connections, including cleaning for refixing, complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of capacity exc 250 ltr but n exc 500 ltr. (Cleaning repairing, etc. measured separately), complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing and connections 25 or 32 mm dia in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed by Engineer-in-Charge.
Supplying and laying 32mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 32mm Male Brass Threaded Adaptor (MTA/ MBTA), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 32mm Female Brass Threaded Adaptor (MTA/ MBTA), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 32mm size tank union, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 25mm thick PCC 1:2:4 type B-0 using 12.5 mm graded aggregate as in leveling course, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for double charged vitrified ceramic tiles with light shade 10 mm thick Square or Rectangular polished area of each tilles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15mm thick scread bedding in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for double charged vitrified ceramic tiles with light shade 10 mm thick Square or Rectangular polished area of each tilles vertical surfaces exceeding 0.42 sqm but not exceeding 1.00 sqm as in skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 10 mm thick backing coat in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 15mm thick quartz stone slab fixed over 10 mm thick cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment on wall or ceiling surfaces, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 3mm thick wall care putty on wall surfaces in any layers and make even and smooth, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 3mm thick wall care putty on ceiling surfaces in any layers and make even and smooth, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new or old surfaces and applying two coats of oil bound distemper on wall or ceiling surfaces over a coat of primer, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Pre-cast cement concrete block type C-1, 1 : 3 : 6 (using 20 mm graded stone aggregate) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1 : 6, complete all as specified and directed by Engineer-in-Charge.
Material & Labour Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1 : 4 and making even and smooth surfaces without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new or old plastered/scraped surfaces and applying two or more coats of 100% Premium Acrylic emulusion paint having VOC 50gm/litre and UV resistance as per IS 15489 : 2004, Alkali and Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with Silicon Aditives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cement concrete type B-1, 1 : 2 : 4 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
Formwork to rough finished flat sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing roller for Fabricated Aluminium windows, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Lock for aluminium window shutter, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 12mm thick Prelaminated particle board both side with decorative choice laminations fixing in partition to door shutters or in any position, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 18mm thick Prelaminated particle board both side with decorative choice laminations fixing in partition to door shutters or in any position, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Aluminium anodised, barrel tower bolts 100mm long of extruded section and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Stainless Steel Furniture hinge for cupboard shutters, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Magnatic catcher for shutter, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 50mm dia, polished, hard wood knobs fixed with screws, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 25mm dia decorative Draphery rod with brackets fixed in walls with wooden/plastic gutties and screws, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Stainless steel fancy type glass door handle 250mm long, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Stainless steel turn knob lock for 8 to 12 mm thick sheet glass, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Heavy duty suitable for more than 120.00 Kg double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed including cutting of floor and making good in Cement Mortar 1 : 3, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 12mm thick toughened one way sheet glass exceeding 0.50 sqm in each pane in required sizes, secured in aluminium frame with rubber gasket, joined / sealed with silicon, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in a square not exceeding 0.5 Sqm in each pane (to be fixed upto four storey of bldgs), complete all as specified and directed by Engineer-in-Charge.
At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed by Engineer-in-Charge.
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed by Engineer-in-Charge.
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing UPVC valley gutter fixed with clamp, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles not exceeding 5Kg each articles, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing Rolled Mild Steel as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation surfaces of any description over 10cm width or girth not otherwise described two coat synthetic enamel paint over a coat red oxide, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Plain cement concrete type C-1, 1:3:6 (20mm graded stone aggregate) as bed plates to vertical steel posts, etc., including necessary form work, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 6mm thick polycarbonate sheet with coach screw in roof sheeting, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe?290 Gde-E-165, complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' E/M ITEMS
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-Charge. Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
Material & Labour for Point wiring complete with 1.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc., complete all as specified and directed by Engineer-in-Charge. Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
One light point or one fan point, one bell point controlled by one switch with cables 1.5 Sqmm size
One 3 pin socket outlet 6 amps on the independent, with cables 1.5 Sqmm size
One 3 pin socket outlet 6 amps on the same board with other switches, with cables 1.5 Sqmm size
Material & Labour for Point wiring complete with 2.5 Sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc. fixed concealed/ recessed in wall or ceiling etc. including 2.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc., complete all as specified and directed by Engineer-in-Charge. Note: Cost of Making Good of existing disturbed surface deemed to be included in unit rate.
Supply & Fixing in repair modular type 6 A one-way switch, 1 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing in repair modular type 16 A one-way switch, 1 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing in repair modular socket, 6 Amps, 2/3 pin combind 2 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing in repair modular socket, 6/16 Amps, 2/3 pin combind 2 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing in repair modular fan regulator, 100 watt, 1 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing ceiling rose, surface bakelite, 65x17 mm three terminals, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing modular type bell switch 6 A one-way switch, 1 module, complete all as specified and directed by Engineer-in-Charge. Make :- Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply & Fixing bell modular type of two module, complete all as specified and directed by Engineer-in-Charge. Make :-Anchor Roma (Urban)/ Legrand (Myrius)/ L&T (EnGem)
Supply and fixing in repair surface mounted LED batten fitting 18 Watt , with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire, complete all as specified and directed by Engineer-in-Charge. Make : Philips / Wipro / Osram
Supply and fixing in repair surface mounted LED batten fitting 10/12 Watt , with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire, complete all as specified and directed by Engineer-in-Charge. Make : Philips / Wipro / crompton
Supply & fixing in repair LED lights, Nominal watt 35 Watt, Nominal lumen efficiency 120 lumen/Watt, high pressure die cast aluminium housing, 140-270V, 50 Hz,LED street light luminaries to be mounted on wall of Buildings including 3 core 1.5 sqmm PVC insulated copper cable from control box to fitting and mounting bracket of suiatble size with clamp, screw and washer, complete all as specified and directed by Engineer-in-Charge. Make: Wipro / Philips/ Osram
Supply & Fixing in repair surface mounted type downlighter LED fitting 36 Watt ,5700K, cool white, with driver 2x2 ft complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire, complete all as specified and directed by Engineer-in-Charge. Make : Philips /Wipro / Crompton
Supply & Fixing in repair surface mounted type downlighter LED fitting 36 Watt , 5700K, cool white, with driver 4x1 ft complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire, complete all as specified and directed by Engineer-in-Charge. Make : Philips /Wipro /Crompton
Supply & Fixing in repair MCB (DB) TPN 4 way double door 415 V made of sheet metal enclosure for MCB's as incomming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Supply & Fixing in repair MCB (DB) SPN 12 way double door 415 V made of sheet metal enclosure for MCB's as incomming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Supply & Fixing in repair MCB (DB) SPN 8 way double door 415 V made of sheet metal enclosure for MCB's as incomming and SPN/SP MCB as outgoing, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Supply & Fixing in repair MCB TPN pole 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 40/63 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Supply & Fixing in repair MCB SPN pole 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 40/63 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Supply & Fixing in repair MCB SP 240 volt C curve 10 KA,ISI marked as per IS/IEC 60898-1 2002 of 6/32 Amps capacity IP 20, complete all as specified and directed by Engineer-in-Charge. Make: Hager / Legrand/ schneider
Material & Labour for submain wiring in existing surface/ Wall using IS:694- 1990 marked 1.1 kV grade single core HR-FR flexible cable having multi- drawn thin strands of electrolytic copper conductors and insulation for phase & neutral and earth continuity conductor connecting to earth dolly, drawn in medium grade non-metallic PVC conduit not less than 25 mm dia., colour-coded and making good of disturbed surfaces of wall/ceiling/floor, complete all as specified and directed by Engineer-in-Charge. NOTE: 02 runs of phase & neutral conductors, 01 run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length.
2 X 2.5 Sqmm + 1 X 2.5 Sqmm
2 X 4 Sqmm + 1 X 4 Sqmm
2 X 6 Sqmm + 1 X 6 Sqmm
Taking down existing sub main wiring complete, including fixture and fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete all as specified and directed by Engineer-in-Charge. Make: Almonard/Havells/khaitan
Supply & fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with BEE Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge. Make: Almonard/Havells/khaitan
Supply & fixing modular MCB, 25/32 Amps, 1 module, complete all as specified and directed by Engineer-in-Charge. Make :- Legrand/ Schneider / Hager
JAY BHARAT METAL SUPPLIERS
Harsh Infrastructure
K B N TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .