Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAdmitted-Finance | ₹45.2 L | L1 | Admitted-Finance |
| 2 | L2₹46.8 L+₹1.5 L (3.37%)Admitted-Finance NEAR EAST WEST PUBLIC SCHOOL SHAHABAD GATE RAMPUR U P | ₹46.8 L+₹1.5 L (3.37%) | L2 | Admitted-Finance |
| 3 | L3₹47.9 L+₹2.7 L (5.99%)Admitted-Finance | ₹47.9 L+₹2.7 L (5.99%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TNK Electricals L2 | SONU ELECTRICALS L3 | J AND J COMPANY L1 |
|---|---|---|---|---|---|---|
| 1.00 | Cartage of material including Loading / Unloading of Small material from store centre at Rudrapur/ Haldwani approximate distance 05-35 KM. | 150 | Qtls. | 250 ₹37,500 | 270 ₹40,500 | 245 ₹36,750 Lowest |
| 2.00 | Cartage of ST Pole, SP-55 including Loading / nloading from store centre at Haldwani approximate distance 05-35KM. | 132 | No. | 560 ₹73,920 | 595 ₹78,540 | 547 ₹72,204 Lowest |
| 3.00 | Cartage of head load Cartage of material including Loading / Unloading of Small material from JE store/ Dump Store centre to work site approximate distance upto 3KM. | 150 | No. | 170 ₹25,500 | 195 ₹29,250 | 148 ₹22,200 Lowest |
| 4.00 | Cartage of head load Cartage of ST Pole, SP-55 including Loading / Unloading of Small material from JE store/ Dump Store centre to work site approximate distance upto 3KM. | 132 | Nos. | 260 ₹34,320 | 280 ₹36,960 | 245 ₹32,340 Lowest |
| 5.00 | Erection of following STP SP-55 Single pole support( Supplied by the department) including excavation of pits, 0.6x0.6x2.0 Mtr. & grouting of pole in C.C. ratio 1:4:8 in size 0.45x0.45x1.8 mtr and making kicking block of size(Height 0.45x0.45 mtr round) above ground level on the pole in 1:3:6 CC including cost of drilling holes and cutting as required and cost of all material (sand, cement and stone grit ) required for the work, construction work with fitting of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge. | 132 | Nos. | 3,600 ₹4,75,200 | 3,650 ₹4,81,800 | 3,480 ₹4,59,360 Lowest |
| 6.00 | Fixing of Stay rod as per RESPO drawing RES-16 with stay rod 16x1800 stay wire 7/10 swg( Stay set and stay wire will be provided by department) required for proper completion of work as per direction of Engineer-In-Charge. | 67 | Nos. | 410 ₹27,470 | 450 ₹30,150 | 390 ₹26,130 Lowest |
| 7.00 | Grouting of stay set including excavation of pit size 0.6x0.6x1.2 Mtr. for set set 67 Nos. @ each 0.108 cu.meter)Total. 7.236 cu. Mtr. as per norms and earth filling complete in all respect with cost of cement, sand & stone ballast and fixing of all other items with clamps including proper nozelling etc. required for proper completion of work as per direction of Engineer-in -Charge/ | 7.24 | cu.mtr. | 4,150 ₹30,029.4 | 4,250 ₹30,753 | 4,070 ₹29,450.52 Lowest |
| 8.00 | Excavation of pit size 0.6x0.6x1.2 Mtr. for set set 67 Nos. @ each 0.432 cu.meter)Total.28.944 cu. Mtr. as per norms and earth filling complete in all respect with cost of cement, sand & stone ballast and fixing of all other items with clamps including proper nozelling etc. required for proper completion of work as per direction of Engineer-in -Charge/ | 28.94 | cu.mtr. | 200 ₹5,788.8 | 220 ₹6,367.68 | 188 ₹5,441.47 Lowest |
| 9.00 | Providing and fixing of M.S. packing behind guarding angle. | 805 | Nos. | 610 ₹4,91,050 | 640 ₹5,15,200 | 595 ₹4,78,975 Lowest |
| 10.00 | Febrication of straight X-arm complete. | 3,960 | Kg. | 19 ₹75,240 | 20 ₹79,200 | 17 ₹67,320 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Jan 2021, 3:00 pmClosed
Superintending Engineer
SE,EDC,Rudrapur
Guarding of 11KV. line under 33/11KV. Sub station, Matkota area under EDD,Rudrapur
2020_UPCL3_28443_1
EDC(USN)41/2020-21
Open Tender
Electrical Works
Item Rate
180 days
Rudrapur
Pl. refer tender documents.
3 documents required · 3 mandatory
₹2,360
SE,EDC,Rudrapur
₹1 L
11 Feb 2021
26 Dec 2020
19 Jan 2021
28 Dec 2020
18 Jan 2021
28 Dec 2020
Amount
Cartage of material including Loading / Unloading of Small material from store centre at Rudrapur/ Haldwani approximate distance 05-35 KM.
Cartage of ST Pole, SP-55 including Loading / nloading from store centre at Haldwani approximate distance 05-35KM.
Cartage of head load Cartage of material including Loading / Unloading of Small material from JE store/ Dump Store centre to work site approximate distance upto 3KM.
Cartage of head load Cartage of ST Pole, SP-55 including Loading / Unloading of Small material from JE store/ Dump Store centre to work site approximate distance upto 3KM.
Erection of following STP SP-55 Single pole support( Supplied by the department) including excavation of pits, 0.6x0.6x2.0 Mtr. & grouting of pole in C.C. ratio 1:4:8 in size 0.45x0.45x1.8 mtr and making kicking block of size(Height 0.45x0.45 mtr round) above ground level on the pole in 1:3:6 CC including cost of drilling holes and cutting as required and cost of all material (sand, cement and stone grit ) required for the work, construction work with fitting of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge.
Fixing of Stay rod as per RESPO drawing RES-16 with stay rod 16x1800 stay wire 7/10 swg( Stay set and stay wire will be provided by department) required for proper completion of work as per direction of Engineer-In-Charge.
Grouting of stay set including excavation of pit size 0.6x0.6x1.2 Mtr. for set set 67 Nos. @ each 0.108 cu.meter)Total. 7.236 cu. Mtr. as per norms and earth filling complete in all respect with cost of cement, sand & stone ballast and fixing of all other items with clamps including proper nozelling etc. required for proper completion of work as per direction of Engineer-in -Charge/
Excavation of pit size 0.6x0.6x1.2 Mtr. for set set 67 Nos. @ each 0.432 cu.meter)Total.28.944 cu. Mtr. as per norms and earth filling complete in all respect with cost of cement, sand & stone ballast and fixing of all other items with clamps including proper nozelling etc. required for proper completion of work as per direction of Engineer-in -Charge/
Providing and fixing of M.S. packing behind guarding angle.
Febrication of straight X-arm complete.
Fixing of Guarding for protection of road/HT line at crossing loacation consisting of guarding angle 65x65x6mm. And G.I. wire No. 6swg for cross wire( Supplied by department ) including 4Nos. I bolt and two nos turn bukkle to be provided by contractor .
Febrication & Fixing of M.S. Angle size 65x65x6 mm. icluding drilling holes as required etc as per instructions of Engineer-In- Charge.
Painting of of STP -55 Single support with one coat of red oxide primer & two coats of aluminum paint Berger Luxol quality over one coat of red oxide primer and P.O. red and two strip of fluorescent altemate red and white paint 30CM wide upto 1.5 Meter from ground level. complete in all respect including cost of Paint.
Lopping, Chopping of tree branches.
Supply of Stay Clamps M.S. Clamps for S.P.-55 made of M.S. flat of size 65x8 mm. with 65x16mm Bolt, Nut & washers duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs, complete in all respect as per sample.
Supply of X-arm Holding clamps M.S. Clamps for S.P.-55 made of M.S. flat of size 65x8 mm. with 65x16mm Bolt, Nut & washers duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs, complete in all respect as per sample .
Supply of M.S. Nut & bolts of size as per site requirement.
Supply of Stay Insulator for stay wire 7/10 swg.as per site requirement.
TNK Electricals
SONU ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .