Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC BANSHBARI MALDA | ₹37.5 L | L1 | Accepted-AOC Lowest Bidder. |
| 2 | L2₹39.1 LRejected-AOC DIAMOND HARBOUR NEWTOWN DISTT SOUTH 24 PARGANAS PIN 743331 | 24 PARAGANAS SOUTH | WEST BENGAL | 743331 | ₹39.1 L | L2 | Rejected-AOC Not Lowest Bidder. |
| 3 | L3₹39.4 LRejected-AOC | ₹39.4 L | L3 | Rejected-AOC Not Lowest Bidder. |
Tender Value
₹44.7 L
EMD Value
₹89,371
Closing Date
14 Jan 2026, 5:00 pmClosed
The ACE and PSIC PPSP Site
PPSP Admin Building, PPSP Site, Bagmundi,Purulia 723152
Repair and maintenance work of Officers Field Hostel - 1,2,3 buildings under PPSP Site, Bagmundi, Purulia.
2025_WBSED_973235_1
PPSP/S/e-TEN/C/25-26/NIT-08 DATED 12.12.2025
Open Tender
CIVIL WORKS
PPSP Site, Bagmundi
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹89,371
Yes
14 Mar 2026
19 Dec 2025
17 Jan 2026
19 Dec 2025
14 Jan 2026
19 Dec 2025
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
In ground floor including roof.
In 1st floor including roof.
In 2nd floor including roof.
Above roof of 2nd floor.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m . Up to 150 mm. thick
In ground floor including roof.
In 1st floor including roof.
In 2nd floor including roof.
Above roof of 2nd floor.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
In ground floor including roof.
In 1st floor including roof.
In 2nd floor including roof.
Above roof of 2nd floor.
Stripping off worn out plaster and raking out joints of walls, ceilings etc. up to any height and in any floor including removing rubbish within a lead of 75m as directed.
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1.5 m.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (6 mm nominal size)excluding shuttering and reinforcement, if any as per relevant IS codes. Pakur variety.
In ground floor and foundation.
In 1st floor including roof.
In 2nd floor including roof.
Above roof of 2nd floor.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety
In ground floor including roof.
In 1st floor including roof.
In 2nd floor including roof.
Above roof of 2nd floor.
Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (up to roof of ground floor)
25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
In ground floor including roof.
In 1st floor including roof.
In 2nd floor including roof.
In 2nd floor including roof.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Tor steel/Mild Steel (SAIL/TATA/RINL)
For works in foundation, basement and up to roof of ground floor/up to 4 m.
In 1st Floor.
In 2nd Floor.
In 2nd floor including roof.
Brick work with 1st class bricks in cement mortar (1:6).
In superstructure, ground floor
In 1st Floor.
In 2nd Floor.
In 2nd floor including roof.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)
In Ground Floor.
In 1st Floor.
In 2nd Floor.
In 2nd floor including roof.
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two(2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification]
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). Note: Applicable only when the full diameter of reinforcement steel is exposed.
Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement 25 mm. thick.
In ground floor.
In 1st Floor.
In 2nd Floor.
Labour for Chipping of concrete surface before taking up Plastering work.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. [Excluding cost of chipping over concrete surface]
With 1:4 cement mortar 10 mm thick plaster
In Ground floor
In 1st floor.
In 2nd floor.
Above roof of 2nd floor.
With 1:6 cement mortar In Ground floor.
20 mm thick plaster
15 mm thick plaster
With 1:6 cement mortar In 1st floor.
20 mm thick plaster
15 mm thick plaster
With 1:6 cement mortar in 2nd floor.
20 mm thick plaster
15 mm thick plaster
With 1:6 cement mortar Above roof of 2nd floor.
20 mm thick plaster
15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Easing, oiling and adjusting the steel shutters including scraping all members and fitting so as to make the shutters easily operable ( no extra payment will be made for taking out and fixing glass, if necessary). (Each means a pair of shutter in a frame).
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills.
Two point nose steel handle including fitting and fixing.
Steel peg stay 300 mm long including fitting and fixing.
Top hung ventilators as per I.S. sizes 580 mm.
In ground floor.
In 1st Floor.
In 2nd floor.
Fixed type steel windows as per IS sizes with horizontal glazing bars.
In ground floor.
In 1st Floor.
In 2nd floor.
M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs. Grill weighing above 10 Kg./sq.mtr and upto 16 Kg./sq. mtr.
In ground floor
In 1st floor
In 2nd floor
Welding in M.S. structural work with gas or electric.
Tack weld
Continuous weld
Supplying fitting and fixing door frame with M.S. angle as per drawing & direction of required section. The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . The nuts are to be welded after careful checking with screw. All welding spots should be properly filed or rounded smooth including cost of welding hinges for hinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of 25mm x 6mm flat 225mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete. (Weight of frame shall be calculated for the M.S. sections of frames. Payment of butt hinges, clamps, hasp bolt, socket bolts, screws etc. will be paid separately.)
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately) (Upto area 2.5 Sqm)
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well-seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 32 mm thick shutters (single leaf)
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 50mm. X 1.25mm.
Anodized aluminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. With continuous plate base(Hexagonal/Round rod). 150mm grip x 10mm dia rod.
Anodized aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. 300mm long x 10mm dia bolt.
Anodized aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S specification (I.S: 2681/66) fitted and fixed complete. 300mmx16 dia bolt.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987 4mm thick clear glass.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly , complete as per manufacturer's specification and as per direction of the EIC Two coats.
In ground floor.
In 1st Floor.
In 2nd Floor.
Above roof of 2nd floor.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two coat. Super Protective 100% Acrylic Emulsion.
In ground floor.
In 1st Floor.
In 2nd Floor.
Above roof of 2nd floor.
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
In ground floor.
In 1st Floor.
In 2nd Floor.
Above roof of 2nd floor.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
M.S. gate of Jail type as per approved design made of strong M.Sframe work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
On timber or plastered surface, With super gloss (hi-gloss), two coats (with any shade except white)
On steel or other metal surface, With super gloss (hi-gloss), Two coats (with any shade except white)
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & up to 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)
Supplying best Indian figured glass viz. hammered, fluted, ribbed, pinhead etc. type including cutting to required sizes, setting on putty bases and fitted and fixed with nails and putty complete.(In all floors for internal wall &upto 6 m height for external wall). 3 mm thick (White)
Renewing worn out putty of glass panes
Panes not exceeding 0.2 Sq.m All Floors.
Panes exceeding 0.2 Sq.m but not exceeding 0.5 Sq.m. All Floors.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. Up to roof of 2nd floor. For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m
Taking out rain water down pipe.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.
UPVC Pipes: 160 mm. Dia.
UPVC Fittings: Shoe.160 mm dia.
UPVC Fittings: Bend 87.5 degree. 160 mm dia
Supplying fitting & fixing GI pipes of TATA make with all necessary accessories, special viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc., fitted with holder bats clamps, including cutting pipes, making thread, fitting, fixing etc., complete in all respect including cost of all necessary fittings as required, jointing materials and two coat of painting with approved paint in any position above ground. For Exposed work
15 mm dia. medium quality
20 mm dia. medium quality
25 mm dia. medium quality
32 mm dia. medium quality
40 mm dia. medium quality
Supplying, fitting and fixing Peet's valve full way gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.)
20 mm dia
25 mm dia
32 mm dia
40 mm dia
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
Single Socketed 3 Meter Length
Door Bend (T.S.)
Bend 87.5º
Vent Cowl
Bend 45º
Pipe Clip
Coupler
Plain Tee
Plain Y
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Pakur variety. (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (Other than SAIL/TATA/RINL)
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole /gully pit cover with matching frame.As per I.S- 12592(M.D) 1 MT load bearing capacity round manholelifter hook with matching frame of size Cover: 450 mm X 40 mm Frame: 540 mm X 80 mm opening: 360mm Weight: 34 Kg. (approx)
Removing sludge from septic tank, soak well etc. by mathor labour including disposal of the same outside the compound as directed. Upto 50 Users Within a limit of 150 metre.
Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats & repairing the pit as necessary including fitting the slab.
Dismantling H.C.I pipe with fittings including melting lead caulked joints.
Day to day supply of mazdoor (male) for different works.
Labour welfare cess @1% & rouning of +₹0.50
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.27 MB
BOQ_2368628.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid