Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | ₹20.2 L Quoted ₹22.3 L | L1 | Accepted-AOC Accepted for acceptance being lowest. |
| 2 | L2₹23.3 L+₹97,747 (4.39%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹23.3 L+₹97,747 (4.39%) | L2 | Rejected-Finance Not L1. |
| 3 | L3₹23.3 L+₹1.0 L (4.70%)Rejected-Finance | ₹23.3 L+₹1.0 L (4.70%) | L3 | Rejected-Finance Not L1. |
| 4 | L4₹23.7 L+₹1.4 L (6.44%)Rejected-Finance | ₹23.7 L+₹1.4 L (6.44%) | L4 | Rejected-Finance Not L1. |
| 5 | L5₹24.0 L+₹1.7 L (7.48%)Rejected-Finance | ₹24.0 L+₹1.7 L (7.48%) | L5 | Rejected-Finance Not L1. |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
3 Sept 2021, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF WATER SUPPLY DISTRIBUTION PIPE LINE INCLUDING CLEANING OF OVERHEAD TANKS, OPEN WELL, BORE WELL ALONG WITH CERTAIN OTHER CONNECTED WORKS IN DOMESTIC AREA AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2021_MES_467805_1
8306/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹41,000
Yes
14 Oct 2021
13 Aug 2021
4 Sept 2021
13 Aug 2021
3 Sept 2021
27 Aug 2021
Amount
Taking out unserviceable / defective / damaged / blockage GI pipe 80mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and directed. Note: Exacavation and earthwork shall be measured and paid separately.
Taking out unserviceable / defective / damaged / blockage GI pipe 100mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and directed. Note: Exacavation and earhwork shall be measured and paid for separately.
S&F GI tubing 80mm bore medium grade, ISI Marked conforming to IS 1239, with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert / road crossing etc including testing complete all as specified and directed.
S&F GI tubing 100mm bore medium grade, ISI Marked conforming to IS 1239, with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert / road crossing etc including testing complete all as specified and directed.
Laying only serviceable 80mm bore steel water tubing and including new fittings conforming to IS 1239 such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. (Old serviceable pipe obtained from taking down shall be used).
Laying only serviceable 100mm bore steel water tubing and including new fittings conforming to IS 1239 such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. (Old serviceable pipe obtained from taking down shall be used).
Taking out unserviceable / defective / damaged / blockage DI pipe any class 150mm bore, sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and directed. Note: Exacavation and earhwork shall be measured and paid for separately.
Taking out unserviceable / defective / damaged / blockage DI pipe any class 100mm bore, sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and directed. Note: Exacavation and earhwork shall be measured and paid for separately.
Supply and laying in trenches ductile iron pipes, socket and spigot ends, of size DN 150mm bore, ISI marked centrifugally cast (spun) Ductile iron pressure pipes conforming to IS:8329/2000 classification K-9 rating with nominal wall thickness 6.0mm, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985 all as specified and directed. Make: Jindal SAW pipes/ Electro steel casting Ltd/ Surya Roshini Ltd
Supply and laying in trenches ductile iron pipes, socket and spigot ends, of size 100mm bore, ISI marked centrifugally cast (spun) Ductile iron pressure pipes conforming to IS:8329/2000 classification K-7 rating, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985 all as specified and directed. Make: Jindal SAW pipes/ Electro steel casting Ltd/ Surya Roshini Ltd
Supply and fix in repair high pressure, heavy duty cast iron non return valve / check valve of following sizes, conforming to BS 1868, Class 600, suitable to hydrostatic test pressure for body 156 kg/sqcm & for seat 115 kg/sq cm, both ends flanged in existing line, after removal of old unserviceable non return valve without damaging to existing pipe line complete all as specified and directed. Note: Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item.
150mm dia
100mm dia
Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
S&F in repair DI fitting for DI spigot and socketed / flanged ends pipes like bends (any type, radius and angle) increasing, decreasing or double socketed / flanged tee pieces single branch 'Y' junction double branch, cross collars caps and plugs, connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth suitable for up to 150mm bore pipe complete all as specified and directed. Note :- (i) The weight of the fitting for the purpose of payment shall be actual weight of the fitting or as specified in IS code which ever is less. (ii) Jointing materials such as run lead joint, rubber tyton joint shall be measured & paid separately.
M & L for cleining of RCC overhead tank at verious location at technical area of capacity 10000Lts by continues dewatering till the complete water is removed from the overhead tank by the using suitable capacity non clog diesel engine from set and cleaning of all the accumulated sediments, sludge and foreign particles by using reuired chemicals as per is standards uoto bottom of overhead tank and removing same to a distance exc 250 M bt not exc 500 M and depositing where all as directed.
M & L for cleining of RCC UG sump at various locations inside tech area continues dewatering till the complete water removal from the UG sump by using suiltable capcity non clog diesel engine pump set and cleaning of all the accumulated sediments, sludge and foreigen particles up to bottom of UG sump & removing the same to a distanance exc 250m but not exc 500m and depositing where all as directed for following capacity:-
150000 Litres
5.0 lakh Litres
Note for Item no 15 & 16: (i)Dewatering process shall be continuos as per working hrs.provn of standy arrangement of pump on failure of working pump set shall be arrange by contractor. (ii)Adequate skilled man power shall be employed for cleaning. (iii) all protective arrangement/intrumnent during cleaning and dewatering shall be provided by contractor deemed to be included in the cost of cleaning. (iv) work shall be executed by experienced persons in trade and all safety precaution as per CP norms will be given to the Engr-in-charge before execution and after completion of work.
M & L for repairing of crack in 200 mm bore DI/CI water pipe line by providing mild steel two piece half round clamp fabricated with 60mm wide & 5mm thick mild steel flat, bend to shape,including nut bolt,rubber packing of clamp with corrosive paint and including earthwork excavation etc as specified and directed.
M & L for repairing of crack in 100 mm bore DI/CI/GI water pipe line by providing mild steel two piece half round clamp fabricated with 60mm wide & 5 mm thick mild steel flat, bend to shape welding 25 mm size socket, including nut bolt, rubber packing,drilling hole in existing pipe line & painting and including earthwork excavation etc as specified and directed.
Supply & fix in repair of cast iron Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Packing greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size as under, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
150mm dia
100mm dia
80mm dia
200mm dia
Supply & fix in repair butter fly valve as per IS-13095, complete with fasteners-CS, Gasket- Natural rubber, nominal size as under, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
100mm dia
150mm dia
200mm dia
M & L For fabrication & fixing Mild steel work for covers, supporting clamp of pipes, ladder, railing of over head water tank, under ground sump, open well & water supply installation fabricated with mild steel section such as angle, flat, tee, nut & bolt cutting, welding cold or hot driling hole any shape or size fixing arrangement, including painting with two coats of synthatic enamel paint over a coat of red oxide primer complte using steel section of Fe 290 Grade-165 including dimalntaling of old steel work all as specified and directed.
M & L servicing/maintanance of dual media filter installtion at verious lacation inside tech Area by dismalantling and disconnecting inlet and outlet water connecxtion replacement of entire media filter (sand or antharacite (0.6-0.8 mm) size or as per existing size) in stages as per existing quality of pebbles/sand to obtain back wash flow rate 18-25gpm/sqft and PH between 4-12, cleaning of sand gravel to obtain higher discharge rate at less time and painting extermally with approved colour compalete all as specified and directed.
M & L Repairing/servicing of end suction utility pump with discharge cap : 108 m3/hr, head: 46m coupled with electric motor, by dismantling the pump and replacement of the following parts:-(a) Worn out bearing (DE & NDE) (b) worn out bush (c) sleeve (d) oil seal (e) painting of pump complete and testing of pump after complete repair all all as specified and directed.
M&L for repair to Diesel engine opearted at 1800 RPM of cap 92HP/68KW Make: Kirloskar installed at WWR fire fighting pump house Note: Mather & Platt with taking out and repair/replacement of defective parts as under:
Diesel filter element with gasket
Inhibitor corrosion, tube water bypass & water outlet
Air cleaner element
Engine oil filter element complete
Air filter (inner & outer)
Fuel filter bowl, pre element & micro element
Solenoid switch with wiring complete
Governor cable both inner and outer including RPM adjustment assembly
Set of ring set, dowel for connecting rod, bolt for connecting rod, conneting rod assembly and joint for gear assembly
Taking out choked radiator from engine, drain out coolant and descaling and cleaning with cleaning agent, cleaning of fins by applying pressurized air using blower including replacement of rubber housing set complete
Taking out old/unsv engine belt and replacement of grooved belt complete
Taking out fuel pump, transporting to authourised workshop, dismantling of pump carefully and overhauling
Draining out old unsv engine oil from chamber, cleaning of oil sump complete and filling of new oil 15W40CH4 confirming to specification. Make:Castrol/Valvoline/Servo
Taking out all leaked/deterioted rubber hoses of engine and replacement of hose pipes including clamps complete
Taking out old unsv fuel pipes and replacement of new nylon reinforced PVC fuel pipes with threaded sockets complete set, oil seal, seal O ring, screw captive washer cap
Scraping of old existing paint, oil from body of alternator, radiator, engine, base frame including exhaust pipe / silencer, preparation of surface and filling of cavity using filler material and spray painting to complete pump set and motor set alongwith all accessories including fuel tank with two coats of super enamelled paint of superior quality as approved by AGE E/M and writing of MES/SM No. using black paint of suitable font of letters in background of white paint complete all as specified and directed.
Hirachand Sunderji and co
Sukhi Electricals
Prime Decor
Dara Paras.D
Vijay Construction Co
Nirmal Construction
jitendra c joisar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .