Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.7 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹79.2 L+₹4.2 L (5.55%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹87.8 L+₹12.7 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹1.1 Cr+₹32.2 L (42.9%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Not being lowest |
Tender Value
₹89 L
EMD Value
₹1.6 L
Closing Date
30 Aug 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
COMPREHENSIVE MAINT CONTRACT FOR ATTEND DAY TO DAY COMPLAINTS FOR ALL OTM ACCN AND JOINERY WKS INCLUD FLY PROOFING AND REPAIR CLEANING OF SEWAGE LINE MANHOLE ETC FOR ALL OTMS UNDER AGE B/R-1 IN ARMY AREA JODHPUR UNDER GE (A) NO. 01
2023_MES_605994_1
82324/43/E8
Open Tender
Civil Works
Item Rate
270 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (A) NO. 01
₹1.6 L
Yes
16 Sept 2023
30 Jun 2023
6 Sept 2023
30 Jun 2023
30 Aug 2023
17 Aug 2023
1 Jul 2023 - 20 Jul 2023
Amount
Notes- Applicable for all items:- (a) Establishment of complaint cell:- (i) Complaints cells will be established at each residential/RWAs/Colony and OTM Accommodation (As per locations given by Engineer-in Charge/GE). The numbers of complaints cells in the ibid contract will be five only. (ii) Contractors will deploy manpower/tradesman with requisite tool & plant for smooth functioning of all complaint cells under subject work. The details per complaint cell is as given below :- (aa) Data Entry Operator - 01 per complaint cell. (ab) Attendant - 01 per complaint cell. (ac) Supervisor - As required for management of all the complaint cells under subject tender in consultation with GE/Engr-in charge. (ad) Tradesmen & Helpers - As required for management of all the complaint cells under subject tender in consultation with GE/Engr-in-Charge and will be present in all complaints cells. The numbers of the tradesman shall be adequate to address all the complaints on daily basis. (ae) The Data Entry Operators, Attendants and Supervisors will be deployed from 9AM to 5 PM on all complaint cells to manage the complaints cell.
Notes- Applicable for all items:- (a) Establishment of complaint cell (Contd):- (iii) The contractor will provide compatible computer system, printers, peripheral, consumables, internet connection/Dongle for each complaint cell alongwith requisite furniture for functioning of complaint cell and storage of store as required. (iv) The complaints in the cell will be received through complaint register / site orders book / Verbally / Telephonically / WhatsApp / Mobile / ARMAAN or any other mode/system as evolved and intimated by JE/Engr-in-Charge. The contractor shall take immediate action to register and attend all the complaints. (v) The complaints will be addressed through complaint slips and contractors will prepare abstract of all the complaints received and action taken thereof on daily basis and will submit to JE/Engr-in-Charge. (vi) Feedback :- Complaint slip will be having a feedback system from user which will be obtained for each complaint and will be compiled daily and submitted by contractors to JE/Engr-in-Charge.
Notes- Applicable for all items:- (vii) Dress Code:- (aa) Deployed manpower/tradesmen to attend and resolve the complaint shall wear proper uniform. Dress code for plumber, carpenter, scavenger and Electrician etc. shall be approved by Engr-in-Charge with monogram/badges which shall be fixed on the dress. (ab) The number of workers shall be increased based upon number of complaints and quantum of work involved during working hours as decided by JE/Engr-in-Charge.
Notes- Applicable for all items:- (viii) T&P :- (aa) The contractor is responsible to provide all T& P to all the manpower deployed, items such as Drill Machines, cutters, welding machines, scaffoldings etc as and when required at site. (ab) Any other misc works/services connected with user facilitation as per direction of Engr-in-Charge. (ac) The responsibility of taking the tradesmen to complaint site will be of contractor. (ix) Sign Boards :- For each complaint cell, adequate flex sign board of approved size will be placed in complaint cell by contractor. The content of the flex board will be approved by Engr-in-Charge/GE.
Notes- Applicable for all items:- (b) Penalty Clause Contractors will pay penalty on account of non addressal of complaints in given time frame and quality of feedback as per matrix given below. The penalty will be levied by Engr-in-Charge/GE after ascertaining the quality feedback given by user and time taken to address the complaints and justifiable delay, if any. The penalty matrix is as given below :- PENALTY Time delay Satisfactory Partially satisfied Not satisfied Less than 24 hrs Nil Rs.100 Rs.200 24 hrs to 48 hrs Rs. 200 Rs.300 Rs.400 48 hrs to 72 hrs Rs. 400 Rs.500 Rs.600 72 hrs and more Rs. 600 Rs.700 Rs.800 c) Management of urgent nature of complaints such as leakage, water over flow, sewage, Airlock leakage, No electricity on holiday and after 5 PM till 9 AM everyday will also be the responsibility of contractor. For the same adequate tradesman and helper of lack type etc will be made available in each complaint cell by the contractor. (d) All above aspects shall deemed to have been included in the quoted price by the contractor. (e) Recovery on non wearing of uniform :- The employee and labourers engaged by the contractor under this contract shall wear neat and clean uniforms as approved by Engineer-in-Charge along with name badges, else recovery shall be made @ Rs 100/- per person per day. (f) The quoted rates shall be deemed to be included of all provisions mentioned above. The decision of accepting officer in this regard shall be final and binding and without prejudice to all. No claim/representation shall be entertained in the subject matter.
Notes- Applicable for all items:- (g) Cost of T&P (Incl Ladders) , misc sundry materials , Labours , dresses for labours ,& other safety gears as required shall be deemed to be included in the quoted rates by the contractor for the respective items. (h) The adequet no of workers as required per day to address the day to day maintenance works shall be deployed by contractor. (a) Highly Skilled Plumber/Pipe Fitter (b) Highly Skilled Carpenter (c) Mazdoor/Helper for Pipe Fitter & Carp - (d) Highly Skilled Mason with one Helper - (As & when required) (e) Highly Skilled Welder with one Helper - (As & when required) (f) Highly Skilled Electrician (g) sewer man
Attending and checking complaints of any kind of B/R works, plumbing work (repair of leaking taps, stop valves, angle valves etc with washers etc, repair of flush tanks etc repair of leaking of any types of sanitary fittings and GI Pipes of any dia) , Carpenter work (all type of joinery work for wooden , steel, aluminium) and welding work (repairing rolling shutter ,windows, windows jali, hinges, door frame etc.) complete all as directed and specified. Note : 1.Major parts such as Spindles / phases of CP pillar cocks, wall mixer, WHB mixer, Two way bib taps, CP bib cocks, Angle cocks, window jali replaced if any shall be measured and paid for separately under respective item. 2.New GI pipes replaced if any shall be measured and paid under respective item of this schedule as S&F. This item include for labour part only for removal of blockages of air lock etc. 3.The contractor shall be provided all types of tools and equipments for joinery work such as drilling machine (with all type of drilling rod), cutting blades, Screw tightening machine, nail (any type and size) etc. 4.The contractor shall be provided welding machine , welding rod , gloves, welding glass or any other tools as required completed all as specified and directed by Engr-in charge.
Checking and attending to cleaning and maintenance of sewage system, including blockage/choke in WHB, bottle traps, kitchen sink/Nahani tras/Floor traps, water closet, soil/waste pipe running on external walls of bldgs including junction holes of any description and sewage line of any size upto first manhole in running/flowing order without blockage of any description in any situation manually and mechanically as required including all equipments viz bamboo, tools, sewage pump, sewage machine etc including replacement of defective items/materials and refixing covers to manholes/gully trap in position etc. After cleaning and removing the deposited sludge/solid/liquid material outside MD land complete all as specified and directed.
Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed.
S&F of steel ventilator top hung shutter including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F of steel ventilator top hung shutter including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed.
S&F Factory made steel windows ( glazed) with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars, with or without cooler opening, dovetailed or welded all as specified and as directed. Note:- Glass panes, Guard bars & wire cloth shall be measured and paid seperately.
All as per item No. 4.00 here-in-above, but without glazing bars
M&L rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down shutters of any description area not exceeding 1 Sqm each complete all as specified and as directed.
M&L for 35mm thick factory made 2nd class hard wood glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and directed.
S&F 35 mm thick factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and pannel of 9 mm thicks BWP commercial ply or 12mm veneered particle board with commercial veneered on both faces the size of rails and style as per IS-1003 (Part-I) kiln seasond and chemicadly pressue treated all as specified and directed.
S&F Flush shutters 40 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specifid and directed by engr-in-charge.
S&F of factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded plain color pvc ‘C’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted to the MS Frame/sealed to the stiles & rails with suitable PVC sheet beading, and joined 30mm thick (style) consisting of frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded plain color pvc ‘C’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color pvc sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted the MS Frame/sealed to the stiles & rail with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
M& L for solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F in repair of stainless steel butt hinges 100 mm size, complete all as specified and directed.
S&F in repairs 150mm long aluminium barrel tower bolts of extruded section, complete all as specified and directed.
S&F in repairs 150mm long aluminium anodised extruded handles fabricated type a complete all as specified and directed.
S&F in repairs 300 mm long & 16 mm dia, aluminium anodised extruded sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots, complete all as specified and directed.
M &L in replacement fabrication of pressed steel cupboard shutters using 1.00 mm thick MS plain sheet & with frame 1.25 mm thick bent to shape incl two coats of synthetic enamel paint on internal surfaces & two coats of hammer tone finish on external surfaces alongwith locking arrangement mortice lock handle etc., complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame incld punching or drilling out old glazing pins/ spring clips and provding and fixing new ones, complete all as specified and as directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S&F for 4 mm thick figurred, pin headed glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane, complete all as specified and as directed by Engr-in-Charge.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm, fixing with and including MS flat iron with galvanised wire stapples with and necessary welding, nut bolts etc., as in steel window or door complete all as specified and directed.
S&F in repairs for galvanised mild steel wire cloth, 0.40 mm nominal dia of wire and 1.20 mm average width of aperature fixed with and including palin MS flat iron with galvanised wire stapples with and including necessary welding, nut bolt etc as in steel door window or door complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over & including M&L a coat of pink primer complete all as specified and as directed.
M&L preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including M&L single coat of red- oxide, zinc chrome primer complete all as specified and as directed.
M&L for anodized aluminium frame for doors, window, ventilators (minimum thickness of powder coating 50 micron), with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M&L for anodized aluminium door shutters (minimum thickness of powder coating 50 micron), aluminium section weighing not less than 0.55 kg/ m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.,complete all as specified and as directed.
M&L powder coated anodised aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron), fixed type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and as directed.
M&L for fabrication of aluminium powder coated doors, window/ ventilator any pattern & design (openable with hinges, sliding, tilt and turn, casement , fixed type, villa type) fabricated with anodized aluminium rectangular or any type section in frame with approved design & patterns including fixing of galvanised mild steel wire cloth on the outer side of frame etc; fixed in position, complete all as specified and directed. Note for item No. 27.00 to 30.00:- Glass panes, Grills & wire cloth shall be measured and paid separately under respective Items of Sch 'A'.
Supply only rubber beading complete all as specified.
S&F for aluminium anodized deco grill as per manufacturer instruction, complete all as specified.
M&L for Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specified and as directed.
S&F in repair Aluminium (Die cast) body Door closer hydraulically regulated, designation No 3 universal type,suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed.
S&F in repair aluminium anodised wire cloth 0.40mm nominal dia of wire and average width of aperature 1.40 mm, fixing with and including Al wire stapples with and necessary welding, nut bolts etc., as in Al window or door complete all as specified and directed.
S&F in repair 100mm size single action door spring hinge complete all as speciifed and directed.
S&F in repair 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed
Demolition wall and ceiling boards/PVC wall lining (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and frame work complete all as specified & directed
M&L for GI frame work for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including M&L for applying 02 mm thick plaster of paris over and including S&F gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distemper over & including M&L a coat of wall / ceiling care putty, complete all specified and as directed.
M&L PVC Wall Lining interlocking 5mm thick plain colour fitted into the wall with strips including fillets on joints as per manufacturer’s instruction complete all as specified and directed..
M&L for greasing of existing rolling shutter and making in serviceble condition including smaller part such as bearing etc. complete all as specified and directed..
M&L for welding in repair exc 2.5 cm but n exc 5 cm in length thickness of metal to be welded n exc 6mm., complete all as specified and directed..
M&L repair to window including taking down replacement of unserviceable hinges device box type handle making them serviceable condition on refixing on same opening making the soffit and jomb good condition , complete all as specified and directed..
S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed.
M&L for 2nd class hard wood ,plain ,solid ,straight chowkats and frames , wrought , framed rebated on the solid, rounded or chamfered , put togather with glue pinned at joint supplied and fixed incl taking down old one with cabinet, complete all as specified and directed..
S&F as in repair providing pre laminted particle board exterior grade prelaminated both sides and decorative choice fixed for kitchen cupboard and shelving complete 18 /19 mm thick, complete all as specified and directed..
S&F continuous hinges mild steel bright finish or electroglavnised width of flap 30mm, complete all as specified and directed..
S&F 40mm dia cupboards knobs fixed with nuts screw and washer of aluminium anoised with a magnet to keep the shutter in place when closed, complete all as specified and directed..
Dismantling, stone slab, floor, hearth or wall tiling including cement mortar bedding (but not backing) & cutting chasing pinning & etc., and rubbish off the premises, complete all as directed.
M&L in repair for Machine cut kota stone slab18-20mm thick as in shelves (in single piece), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete joint with and including screed bed in CM 1:4 complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L 40 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring/hard standing laid in alternative bays using glass dividing strips including finishing cement concrete surface even and smooth without using extra cement complete all as specified & as directed. Note:- Glass dividing strip shall be measured & paid separately.
Supply only 38mm wide and 3mm thick glass dividing strip complete all as specified & directed
M&L 50 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight in 2 mtr interval, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for 10 mm thick Rendering in CM 1:3 on fair faces of brick work or conc surfaces as in ceilings/chajja/facia & finished even & smooth w/o using extra cement, complete all as specified and as directed.
Demolition of damaged downward hanging projection etc of chhajja (upto G+2 level), cutting the reinforcement and rendering 10 mm thick CM (1:3) on concrete / stone masonry surfacesfinished even and smooth & made corner sharp with proper curing 7 days and applying 2 coats of cement base paint including necessary scaffolding, formwork and taking complete measures of safety, required T&P etc, complete all as specified and as directed by Engr-in-Charge.
M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface fair and even without using extra cement, and applying 2 coats of cement base paintcomplete all as specified and as directed.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper white or tinted over & including M&L for 2-3 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfacescomplete all as specified and as directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of white wash on wall, complete all as specified and directed.
M&L for preparation of old decorated wall surfaces plastered or unplastered, including cornices pilasters by brooming down or steel wire brushing and efforescent salts and applying one coat of distemper oil emulsion on wall (white or tinted), coloured and shade as approved by GE, complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper white or tinted over & including M&L for 2-3 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfacescomplete all as specified and as directed.
M&L for non skid ceramic coloured tiles, digital series (premium quality) of size300mm X 300mm X 7 to 8 mm thick (square/rectangular) (shade and pattern as approved by GE), as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including M&L 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed.
M&L for glazed colour ceramic tiles digital series(premium quality) of size 300X200X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:4), complete all as specified and directed.
M&L for glazed colour ceramic tiles digital series(premium quality) of size 300X450X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:4), complete all as specified and directed.
All as per item No. 67.00 here-in-above, but size of tile exceeding 0.11 Sqm but n.exc. 0.18 sqm .
All as per item No. 70.00 here-in-above, but as in skirting over & including M&L 10 mm thick backing coat in CM 1:4.
All as per item No. 67.00 here-in-above, but size of tile exceeding 0.18 Sqm but n.exc. 0.38 sqm .
All as per item No. 72.00 here-in-above, but as in skirting over & including M&L 10 mm thick backing coat in CM 1:4.
M&L for light shade vitrified ceramic tiles, 9-10 mm thick (square/ rectagular) polished, area of each tiles not exceeding 0.36 sqm, (size & shape, shade and pattern as approved by GE), as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, over & including M&L 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
All as per item No. 74.00 here-in-above, but as in skirting over & including M&L 10 mm thick backing coat in CM 1:4.
M&L for Machine cut kota stone slab flooring 18-20 mm thick as in floor over 15mm thick screed bed in CM 1:6 base laid and jointed with grey cement clurry mixed with pigment to match the shade of the slab including rubbing and polishing complete i laid bedded and pointed in any mortar, complete all as specified and directed.
M&L for machine cut kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar laid and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM 1:4 complete all as specified and as directed.
M&L for 15 to 20mm thick machine cut Udaipur green marble (approved by GE of any type work table rubbed and polished) as in cooking platform steps, jambs etc., over and including 15mm thick cement screed bed in CM (1:4) Including cutting and rubbing grinding and granite polish (Mirror image finish) complete all as specified and as directed.
M&L machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006,M-35 Grade, 60 mm thick with 6mm thick anti abrasive topping layer with grey cement and pigments, over and including sand cushioning of 25mm thick complete all as specified and as directed.
S&F machine made precast cement concrete curb stone blocks using Cement concrete 1:3:6 type C2 (20mm stone agg) complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cm X 20cm X 2.5cm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry as in floors/ path etc over and including15mm thick screed bed in CM 1:6 including dismantling old unserviceable tiles complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates with water proofing compound as over roof filling in depression of roof slab/ floor padding/ roof kerbs rounded or chamfered on edges coping etc; complete all as specified and as directed.
Demolition of cement concrete as removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster, padding,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 20 micron HMHDPE , other film 20 micron each thickness 2 mm having weight 2.25 Kg/sqm , using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof paddinglaid in slope grooves 6 mm wide and 10 mm deep at 1.2 m interval in both ways or part thereof and filled with mastic bitumen (1:1) proportion complete all as specified and as directed. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
Supply only water proofing compound complete all as specified.
M&L for carrying out water proofing treatment for sunken portion in the following stages - (i) Taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish of the pemises, cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (ii) M&L for two coat of acrylic cementitious water proofing coating chemical and followed by a overlay protective screed (10mm thick cement mortar (1:4) along with water proofing compound approved make as per manufacturer's instructions) on top surfaces of sunken slab after preprations as mentioned above. Method of application for acrylic cementitious water proofing coating achieved as per manufacturers instruction complete all as specified and directed.
Disconnecting existing tanks setting aside [or lowering if required] for repairs,cleaning etc., and hoisting if required reconnecting and refixing in position of water tanks and including of Cleaning and removing all scale dirt etc from mouths of circulating pipes of water tanks of capacity exceeding 250 litres and not exceeding 500 litres complete all as specified and as directed.
Disconnecting existing tanks setting aside [or lowering if required] for repairs,cleaning etc., and hoisting if required reconnecting and refixing in position of water tanks and including of Cleaning and removing all scale dirt etc from mouths of circulating pipes of water tanks of capacity exceeding 500 litres and not exceeding 1000 litres complete all as specified and as directed.
M&L M&L 50 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in tank plateform at roof, complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed.
All as per item No 90.00 here-in-above, but size of pipe 20 mm bore.
All as per item No 90.00 here-in-above, but size of pipe 15 mm bore.
S&F GI water tubing medium grade, 25 mm bore size, galvanized, with all fittings fixed to wall, ceilings or laid in floors, complete all as specified and as directed.
All as per item No 93.00 here-in-above, but size of pipe 20 mm bore.
All as per item No 93.00 here-in-above, but size of pipe 15 mm bore. including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc complete.
S & F in repair 75mm dia out let, PVC ( SWR) floor trap with grating including jointing to waste pipe with solvent complete all as specified and as directed.
S&F as in repairs of stop cock regular body with adujstable wall flange with fancy type chromium plated with (concealed type) 15mm dia for iron pipe etc complete all as specified and as directed.
S&F in replacement 500 ltrs capacity rotational moulded polythene water storage tanks, white coloured, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I, including demolition of existing RCC tank on roof, of capacity exceeding 300 litr but n. exc. 500 litr &removal unserviceable materials, debris and rubbish to a distance out side MD land and M&L 100mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregates, as in platfoRM of required size for water storage tank over roof slab and finishing even & smooth wihtout using extra cement with 15mm thick plastering in cement mortar 1:4, making good all existing disturb surfaces, and with fixing arrangement complete all as specified and directed.
S&F in replacement rotational moulded polythene water storage tanks of 500 ltrs capacity, white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I with including dismantling old tanks complete all as specified and as directed.
All as per item No. 101.00 here-in-above, but tank capacity 1000 Ltrs capacity
S & F in repairs ball valves 20mm dia bore high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms, complete all as specified and as directed.
S&F in repairs PVC Flexible waste pipe 32 mm to 40 mm dia with socket for steel sink/WHB upto floor level and any length but not less than 0.85 Mtr, complete all as specified and as directed.
S&F in repairs of CP mild steel grating with or without hole 125 mm dia, complete all as specified and as directed
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed complete all as specified & directed.
M&L precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in solid block masonry 10cm thick and setting in cement mortar 1:4 complete all as specified & directed by Engineer-in-charge.
M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub base as in floor complete all as specified and as directed .
M&L PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregate as in coping, benching/ channels of manholes including demolition of existing PCC etc complete all as specified and as directed .
Repairs to any bib tap /pillar taps/stop valves and replacing of old washer with new nylon washer suitable for 15mm to 20 mm dia pipe size and completely removing to leakage of water complete all as specified & directed.
S&F Phase for 15mm bore brass or CP brass stop cocks, bib taps etc, fixed in repairs complete all as specified and as directed
S&F in repairs bib taps standard of PTMT any colour high pressure screwed for iron pipe & fixed (minimum weight 15 mm 90gm/each), , complete all as specified and directed.
S&F in replacement of bib cock with flange 15mm dia, chromium plated, brass, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in replacement of bib cock with flange 15mm dia, cast copper alloy, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair 15 mm bore CP brass angular stop cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in repair 15 mm bore CP brass stop cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in repair 15 mm bore stop cock, cast copper alloy, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in repair 20 mm bore stop cock, cast copper alloy, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in repair 20mm bore PTMT ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed.
S&F in repair 15mm bore PTMT ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and as directed.
S&F in repair 15 mm bore CP brass two way bib cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in repair 15 mm bore CP brass two way angle cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed.
S&F in replacement Wall Mixer 3-in-1 System with both Hand Shower and Overhead Shower 150X150mm Squarel Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System Complete with 115mm Long Bend Pipe (both are match with wall mixture), Connecting Legs & Wall Flange, chromium plated brass, fancy type 15mm dia complete all as specified and as directed.
S & F in repair CP brass Bidet spray (Health faucet) with 1 meter PVC tube and holder, complete all as specified and directed.
S&Fin repair corner sheet glass of 5mm thick, 200mm to 250mm size,as in shelf , fancy type, triamgular in shape and one side circular complete all as specified and directed.
S & F in repair stainless toilet paper holder fixed to wall with CP brass screws complete all as specified and as directed.
M&L for replacement of PTMT symet body towel rail 600mm long fixed to wall with chromium plated screws and wooden gutties ( Minimum weight 170 gms ) complete all as specified and as directed.
M&L for replacement of PVC jet spray with flexible pipe length not less than 1 meter fixed to EWC suitable for 15mm bore pipe
S&F in repairs GI (medium grade) small fittings such as i.e., socket, elbow, nipple, Tee, Reducer sockets & etc., suitable for 15mm bore pipe, complete all as specified and as directed. (Larger bore shall taken into account)
S&F in repairs GI (medium grade) small fittings such as i.e., socket, elbow, nipple, Tee, Reducer sockets & etc., suitable for 20mm bore pipe, complete all as specified and as directed. (Larger bore shall taken into account)
S&F in repairs GI (medium grade) small fittings such as i.e., union, tank nipple, suitable for 15mm bore pipe, complete all as specified and as directed. (Larger bore shall taken into account)
S&F in repairs GI (medium grade) small fittings such as i.e.,reducer socket 25 X 15 mm, complete all as specified and as directed.
S&F in replacement 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia, jointing WC, complete all as specified and as directed.
Refixing after repairing of 10 ltrs capacity flushing cistern, low level, with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia, jointing WC, complete all as specified and as directed.
S&F in repairs internal fittings complete including handle for PVC low level flushing cistern, as per existing make & model, complete all as specified and as directed.
Repair/Adjustment to washer /siphon etc for high or low level flushing cistern any type any make including replacement of washer, check nuts, plug and making it functional complete all as specified and as directed
S&F in repair PVC ball valve of PVC low flushing cistern, as per existing make & model, complete all as specified and as directed.
S&F in repair PVC handle including lever for low level flushing cistern, as per existing make & model,complete all as specified and as directed
S&F in repair PVC flush pipe 32 mm dia for low level flushing cistern, fixed in repairs complete. Including re fixing of cistern at its position complete all as specified and as directed.
S&F in repair Mild Steel CP hinging device for plastic seat cover of EWC, complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of size 450mm complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of size 600mm complete all as specified and as directed.
S&F Fixing in replacement English seat cover coloured pattern with flat bottom and cover mild steel hinging device complete
S & F in repairs vitreous china ware wash hand basin, white, flat back of size 630 mm X 450 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe,Pcomplete all as specified and as directed.
S&F in repairs stainles steel sink with drainage board 1mm thick for kitchen, with plug, waste pipe, washers including bedding in cement mortar to dwarf wall or including fixing cantiliver brackets and connecting union to pipe overall size 915mmx460mm with bowl size 410mmx 330mmx160mm, complete all as specified and as directed.
S&F in repair swivel shower of PTMT any colour for fixing with 15mm bore pipe with shower arm 195mm long with bend of 45 degree with flange of PTMT any colour (minimum weight 40 gms) complete all as specified and as directed .
S&F in repair 125mm dia PTMT grating fixed over trap with white cement complete all as specified.
S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed.
S & F in repairs stainless steel plate rack of size 780mm X 900mm X 250mm of approved pattern made out of stainless steel sheet 0.56 mm thick with round 8mm dia rods complete all as specified and directed.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe complete all as specified and as directed .
S&F Waste coupling of PTMT (half or full threaded) 32 mm bore (minimum weight 45 gms) fixed in repairs complete all as specified and as directed.
S&F Waste coupling of PTMT (half or full threaded) 40 mm bore (minimum weight 60 gms) fixed in repairs complete all as specified and as directed.
S&F Waste coupling of PTMT 32 mm bore with waste pipe, for sink, fixed in repairs complete all as specified and as directed.
S&F PVC waste pipe, 32mm bore suitable to waste coupling pipe attach with rubber ring joints fixed to waste coupling of sinks/WHBs.
S&F in repair Rotational moulded polyethylene water storage tanks lid with clips, screws locking device complete for 300 ltrs/500 ltrs tanks capacity, complete all as specified and as directed.
M&L 5 cm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings cover stones templates etc n exc 2m in length punched dressed on face and along exposed edges self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n. exc 1.5 mtr depth for foundation, for shafts, wells,cesspits, manholes, Pierholes etc n. exc 10 sqm on plan and n. exc 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed.
All as per item No. 158.00 here-in-above but depth exc 1.5 mtr and n.exc 3.0 mtr deep.
All as per item No. 158.00 here-in-above but getting out in soft/disintegrated rock.
S & F in repairs 150mm bore PVC [SWR] pipes single socketed, heavy duty, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 150mm bore of pipe, complete all as specified and directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 200mm bore of pipe, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for removal of debirs to outside MOD land and depositing where directed, complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-0 by using 12.5mm graded crushed stone aggregate as in surface channels and drains including necessary form work complete all as specified and as directed.
Supply, laying, testing & commissioning of 150 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed complete all as specified and as directed.
Supply, laying, testing & commissioning of 200 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed complete all as specified and as directed.
Supply, laying, testing & commissioning of 300 mm bore Reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 C2 using 40 mm graded crushed stone agg as in foundations filling /plinth protection and mass concrete, including necessary formwork,complete all as specified and as directed.
Demolition of brick or stone / boulder masonry / PCC block walling built in cement mortar including all quoins arches pillars etc but excluding ashler facings, dressed stone work and pre-cast concrete articles and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L squared rubble walling, Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed
All as per item No. 171.00 here-in-above, but except stone
Extra over stone walling for hammer dressing to face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface n exc 20mm and dressing face beds and joints, complete all as specified & directed
M&L for PCC solid building blocks 10 Cm thick 1:2:4 type B1 (using 20mm graded crushed stone aggregate) set in cement mortar (1:6), all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surface (Internally) of walls mixed with WPC, as per manufacturer’s direction and finished the surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surface (externally) of walls mixed with WPC, as per manufacturer’s direction and finished the surface even and smooth without using extra cement, complete all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone agg as in coping of manhole including necessary form work complete all as directed.
Returning , filling in soil (any type) incl spreading levelling, watering and well ramming in layers not exceeding 25 Cm thick, complete all as specified and as directed.
Removing surplus excavated material exc250m but n.exc 500m where directed at a level not exceeding 1.5 Mtr above the starting point, complete all as specified and as directed.
Supply and Fix cast iron foot steps, n. exc 5 each in manholes, complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm bore pipe complete all as specified and as directed.
All as per item No. 181.00 here-in-above, but 200 mm bore pipe
Dismantling of cast iron or PVC pipes of 100/110mm internal dia including fittings, jointed in cement mortar complete all as specified and as directed.
All as per item No. 183.00 here-in-above, but 75 mm bore pipe
S&F 100mm bore (spun cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls with and including MS clamps complete all as specified & directed by Engineer-in-charge.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamp, complete all as specified and as directed.
All as per item No. 186.00 here-in-above, but laid in trenches
All as per item No. 187.00 here-in-above, but 75 mm bore pipe
All as per item No. 186.00 here-in-above, but 75 mm bore pipe
S&F 75mm bore (spun cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls with and including MS clamps complete all as specified & directed by Engineer-in-charge.
S&F PVC (SWR) branch pieces single socketed Y equal or unequal suitable for 110mm bore pipes, complete all as specified and as directed.
S&F PVC (SWR) bends any radius suitable for 110mm bore pipes, complete all as specified and as directed.
S&F PVC (SWR) bends 75mm dia with oval acess door, complete all as specified and as directed.
S&F PVC SWR vent cowl suitable for 110mm bore pipes, complete all as specified and as directed.
S&F PVC SWR vent cowl suitable for 75mm bore pipes, complete all as specified and as directed.
S& F in repairs 75mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S& F in repairs 110 mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S&F 100mm dia CI bends including cutting of holes, complete all as specified and as directed.
S&F 100mm dia CI connector of length 30 cms including cutting of holes with lead joints, complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, single [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 100mm bore pipes complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, double [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 100mm bore pipes complete all as specified and as directed.
S & F cast iron bends with ovall access door [any radius], diminishing pieces or tapers [larger bore measured], for cast Iron soil / waste / vent pipes of 75mm bore complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, single [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 75mm bore pipes complete all as specified and as directed.
S & F cast iron branch pieces with ovall access door, double [equal or unequal] ordinary or inverted [spigot and socketed type] or with parallel branches suitable for 75mm bore pipes complete all as specified and as directed.
M &L for cutting to Bituminious road for laying of RCC hume pipe & making good as per road specification as per direction of Engr-in-Charge.
Cutting and grubbing of bushes grass and tree surrounding sewage line and levelling of ground around the sewage line, finish the surface and removing the waste material to distance exc. 50m and n exc. 250m and clearing the site, complete all as specified and as directed.
Cutting of berms as per existing and making good, complete all as specified and as directed.
Cleaning/taking out sludge/mud/silt from manhole of depth not exceeding 1.00 m manually or mechanically including dewatering manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed. Note :-Sludge/mud/silt shall be measured before taking out from manholes.
All as per item No. 208.00 here-in-above, but depth of manhole exc 1.00 M and n exc 2.00 M
All as per item No. 208.00 here-in-above, but depth of manhole exc 2.00 M and above
Removing Temporarily blockage of inlet of septic tanks with suitable wooden pugs/gunny bags and pumping out/bailing out effluent (liquid/semi liquid) from the septic tanks with diesel engine driven gen sets into closed containers or through PVC Hose pipes & delivering the same outside MOD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly and taking out the blocking arangements of inlet and making the system functional all as specified and directed. Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.
Cleaning/taking out sludge/mud/silt from septic tanks of any size and capacity (work in foul condition) mechanically including dewatering septic tank when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and directed by Engineer-in-charge NOTE:-Sludge/muds/silt including water shall be measured before taking out from septic tank.
S & F in replacement white vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests and PVC 'P' or 'S' trap, including M&L brackets, flush HDPE pipe of 32 mm dia and PVC connection 15mm size, 450 mm long with PTMT nuts & fixing arrangement of cistern, including provision of cement concrete bedding 1:5:10 type E2 complete all as specified and as directed.
S&F vitreous ware wash down water closet [Pedestal Pattern], white [ETWC] including plastic water closet seat back closed pattern with flat bottom and cover including jet spray and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap connecting to drain pipe and flushing pipe etc., complete all as specified and as directed.
Pumping out water inflow caused by spring or tidal or river seepage, broken water mains or drains and the like with pumping set of 5 HP to 9 HP including POL/power consumption & operator maint etc. complete all as sepcified and directed. Note : This item shall be operated only when specifically ordered by Engr-in-charge.
M&L for precast RCC 1:2:4 Type B 1 using 20mm graded stone aggregate as in manhole cover/ drain cover slab with hole/without hole hoisted & laying in position, complete all as sepcified and directed.
Mild steel TMT bars 10mm dia and over cut to length, bent to shape reqd, cutting bending and binding with mild steel wire not less than 0.90mm dia, complete all as sepcified and directed.
S&F 75mm thick Jodhpur type stone slab not exc 2m in length dressed all face & along exposed edged size faced both sided as in drain cover, complete all as sepcified and directed.
M&L for cleaning of all blockage of WC, bath, kitchen, WHB, traps, soil waste/vent pipe (vertical or laid in trenches/floor any type/size), sewage line upto 1st man hole of any section/depth any situations by way of cleaning/desludging man holes by using any type of mannually or mechanically or by way of any other suitable means including foreign material from manholes, traps, pits where required and dircted by Engineer-in-Charge and keeping the sewage system upto 1st man hole functional in prefect condition including final drop out form up to 1st man hole. (working in foul condition with taking precautionary measures equipment shall be provided as required are applicable) all as specified and directed
Attending daily complaints of Jodhpur Mil area by deputing adequate number of teams of qualified Electrician and helper (round the colck) for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system by replacing the U/S items such as switches, sockets, distribution boards, MCB light/power , lamp holders-bracket/ pendent/ batten, bell/ buzzer , push button, ceiling rose, capacitors and other similar, light & power plug, including provisioning of small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 6 Sqmm single core and length not increasing 0.50 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill). Note:- (i) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis. (ii) This item pertains to attending complaints of light/fan/power point, MCB DB including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge. (iii). The complaint is to be attended and rectified on the same day i.e. within 8 hours. (iv) Non attendence of complaints within the stipulated time frame i.e. 8 hours shall invite a penalty of Rs. 200 per complaint/ hours and the penal amount shall be recovered from the RAR / Final bill. (v) Items shall be measured and paid seperately under respective item of Sch 'A'
Supply and fixing in replacement electronic adapoter (as per sample) for LED light up to 30 watt including takingdown old unserviceable electronic adaptor of LED , complete all as specified & directed .
Supply and fixing in repalcement switch piano flush type 6 amp single pole one way 230 V, including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in repalcement switch piano flush type 6 amp single pole two way 230 V including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement switch piano flush type 16 amp single pole one way 230 V including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement bell push AC, 230 Volts, 5 Amps including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement socket out let flush type 3/6 pin suitable for 16 Amp plug top multipurpose 230 V including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing repair bell AC ding dong type 230 volts including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement fan regulator electronic switch/ socket type including dismantling of old unserviceable regulator of any make , complete all as specified & directed .
Supply and fixing in replacement lamp holder insulated body with back plate batten/angle type for batten fittings including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fix in replacement fan capacitor 2.5 m.f.d for ceiling Fan, including dismantling of old unserviceable capacitor of any make , complete all as specified & directed .
Supply and fix in replacement fan capacitor 4 m.f.d for Exhaust Fan, including dismantling of old unserviceable capacitor of any make , complete all as specified & directed .
Supply and fixing in replacement ceiling rose 3 terminals complete , including dismantling of old unserviceable ceiling rose of any make , complete all as specified & directed .
Supply and fixing in replacement Modular switch any type and make 6 amp one way 230 V, including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement Modular switch any type and make 16 amp one way 230 V, including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement Modular socket Any Type and make, 6 amp 5 Pin one way 230 V including dismantling of old unserviceable socket of any make , complete all as specified & directed .
Supply and fixing repair Modular socket Any Type and make, 16 amp 5 Pin one way 230 V including dismantling of old unserviceable socket of any make , complete all as specified & directed .
Supply and fixing in replacement Modular switch any type and make 6 amp two way 230 V including dismantling of old unserviceable switch of any make , complete all as specified & directed .
Supply and fixing in replacement Modular fan Regulator step type and make, 100 watt , 230 Volts, including dismantling of old unserviceable regulator of any make , complete all as specified & directed .
Supply and fixing in replacement modular cover plate with frame 4 module type including concealed MS Box for fixing of modular switch socket, regulators, blank plates etc., including dismantling of old unserviceable cover plate of any make , complete all as specified & directed.
Supply and fixing in replacement modular cover plate with frame 8 module type including concealed MS Box for fixing of modular switch socket, regulators, blank plates etc., including dismantling of old unserviceable cover plate of any make , complete all as specified & directed.
Supply and fixing in replacement modular cover plate with frame 12/16 module type including concealed MS Box for fixing of modular switch socket, regulators, blank plates etc., including dismantling of old unserviceable cover plate of any make , complete all as specified & directed.
Supply and fixing replacement poly carbonate transparent energy meter protection cover temper proof suitable for single phase energy meter etc including dismantling of old unserviceable protection cover plate of any make , complete all as specified & directed .
Supply and fixing in replacement PVC conduit including fitting such as tee,elbow,bend etc 20mm dia ISI (MMS)grade, including dismantling of old unserviceable PVC conduit, complete all as specified & directed .
Supply and fixing in replacement PVC cassing-N-capping including fittings tee,elbow,bend etc 20/25 mm dia ISI (MMS) including dismantling of old unserviceable PVC casing-N-capping, complete all as specified & directed .
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store or repair and refixing in same position including connector from ceiling rose to fan connector complete.
Taking down exhaust fan and refixing and connecting up including provision of cable from ceiling rose to connector to fan
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going, SPN 4 Way including dismantling of old unserviceable DB, complete all as specified & directed .
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way including dismantling of old unserviceable DB, complete all as specified & directed .
S&F replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 100 Amp 10 KA TPN MCCB as incoming complete including dismantling of old unserviceable DB, complete all as specified & directed .
Supply and Fix in replacement MCB Single pole 5-32 Amps ISI marked, including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and Fix in replacement MCB Single pole & neutral 40 Amps ISI marked, including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and Fix in replacement MCB Single pole & neutral 63 to 100. Amps, as per site requirement ISI marked, including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and fixing in replacement MCB TPN 63 Amps, ISI marked, , including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and fixing in replacement MCCB 100 amp TPN, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S, including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and fixing in replacement MCCB 125 amp TPN, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S, including dismantling of old unserviceable MCB, complete all as specified & directed .
Supply and fixing in replacement electronic driver as per sample for LED fitting up to 15 watt , including dismantling of old unserviceable driver, complete all as specified & directed .
Supply and fixing in replacement electronic driver as per sample for LED fitting up to 45 watt including dismantling of old unserviceable driver, complete all as specified & directed .
Taking down bldg security light upto 45 watt and refixing the same after repair including dismantling of old unserviceable, complete all as specified & directed . Note:- Electronic driver shall be measured and paid seperately.
M & L in replacement remote bell ding dong type including dismantling of old unserviceable bell, complete all as specified & directed .
Supply and fix in replacement 2-Watt LED Wall Light decorative type bed light for reading, including dismantling of old unserviceable driver, complete all as specified & directed .
Supply and fixing in replacement of round shape soft glare free light, 6 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser, complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, including dismantling of old unserviceable light, complete all as specified & directed .
S&F in replacement of spot light 6 Watts (Black/ white Body) LED Spot Light, Focus Light (Warm White), including dismantling of old unserviceable light, complete all as specified & directed .
S&F in replacement of PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm, including dismantling of old unserviceable cable, complete all as specified & directed .
All as per item No. 264.00 here-in-above, but cable size 2.50 sqmm
All as per item No. 264.00 here-in-above, but cable size 4.00 sqmm
All as per item No. 264.00 here-in-above, but cable size 6.00 sqmm
S & F in replacement of Street light bracket made out of medium grade GI Pipe, bent to shape including GI Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting, including taking down of old unserviceable bracket, complete all as specified & directed .
Supply and fixing in replacement Modular Bell push any type and make 6 amp one way 230 V , including dismantling of old unserviceable bell push of any make , complete all as specified & directed.
Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc complete all as directed.
M&L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade passing in PVC cassing-N-capping 25/32 mm dia fixed on surface of wall/roof/ceiling with existing/new sunken pressed steel terminal boxes including 3.00 mm thick plastic laminated sheet top cover or (Surface PVC Box as directed by EIC) and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly suitable for One light/fan/bellpush point controlled by one, one way switch, complete all as specified & directed.
All as per item No. 271.00 here-in-above, but one socket outlet 3 pin 5/6 Amps on same board
All as per item No. 271.00 here-in-above, but one socket outlet 3 pin 5/6 Amp on independent board
All as per item No. 271.00 here-in-above, but one light point controlled by two, two-way switches
All as per item No. 271.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M & L for (concealed) point wiring in walls/roof surfaces and hard surface of stone complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic heavy duty PVC concealed conduit of size 20 mm (including Cutting Chases and make good the distrubed surfaces ) as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, all as specified, directed and shown on drgs, suitable for One light/fan/bellpush point controlled by one, one way switch, complete all as specified & directed. Note:- The rates of chase cutting on wall done concealed conduit and steel terminal boxes are included in the unit rates
All as per item No. 276.00 here-in-above, but one socket outlet 3 pin 5/6 Amp on independent board
All as per item No. 276.00 here-in-above, but one socket outlet 3 pin 5/6 Amps on same board
All as per item No. 276.00 here-in-above, but one light point controlled by two, two-way switches
All as per item No. 276.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board .
S&F in repair bakelite sheet not less then 3mm thick of size 275 x 225 MM, after removing all connection including cutting/chassing to accommedate existing fitment and making connection including cadmium plated screws with cup washer, including dismantling of old unserviceable bell push of any make , complete all as specified & directed.
All as per item No. 281.00 here-in-above, but size 225 x 200mm
All as per item No. 281.00 here-in-above, but size 175 x 125 mm
All as per item No. 281.00 here-in-above, but size 100 x 100 mm
M & L in replacement GLS Coloured Lamp Red,Green,Milky,0-60 Watt, including dismantling of old unserviceable, complete all as specified & directed.
S&F in replacement LED light fitting 1 X 20/22 watt (4 feet), warm flame decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, including dismantling of old unserviceable light, complete all as specified & directed.
S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size c, including dismantling of old unserviceable light, complete all as specified & directed. Make Philips/Bajaj/Havells
S & F in replacement LED Bulb threaded types in holders 0 to 15 Watts as per existing make and model, including dismantling of old unserviceable light, complete all as specified & directed.
S & F in replacement LED Bulb brown in brightness(Warm tpye) 0 to 15 Watts as per existing make and model, including dismantling of old unserviceable light, complete all as specified & directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size , including dismantling of old unserviceable light, complete all as specified & directed.
S&F in replacement bldg security LED Light Luminaire of 35 Watts having IP 66 protection fiting made out of pressure die cast Aluminium housing with toughened glass with fixing of suitable size medium grade GI pipe band including drilling holling nuts & bolts 2 code of red oxide paint on GI pipe and fixing with wall security light on building wallincluding dismantling of old unserviceable light, complete all as specified & directed. Make: Philips/Bajaj/Havells
S & F in replacement PVC Surface Box including and with one 6 Amps switch and one 6 Amps sockets including dismantling of old unserviceable box, complete all as specified & directed.
S & F in replacement Modular PVC Surface Box including and with one 15 Amps switch and one15 Amps sockets including dismantling of old unserviceable box, complete all as specified & directed.
S & F in replacement PVC Surface Box including and suitable for one 16 Amps switch and one 16 Amps sockets including dismantling of old unserviceable box, complete all as specified & directed.
M&L cutting and taking out old burnout winding & rewinding of submersible pump monoblock type of capacity upto 3 HP, single or three phase, with super enameled copper wire , any make incl connection, testing & commissioning, including dismantling of old unserviceable winding, complete all as specified & directed.
S&F in replacement Decorative Strip Light LED ROPE for indoor & outdoor (water proof) with driver (20 mtr in lenght) including dismantling of old unserviceable light, complete all as specified & directed.
S&F in replacement LED lamp 9W complete including dismantling of old unserviceable lamp, complete all as specified & directed.
M&L in repairs sub main wiring with 4.00 Sq mm single core multistrandred copper conductor PVC insulated FRLS and unsheathed cable passing through PVC concealed conduit and making good the distrurbed surface of wall inc 2.5 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire, including dismantling of old unserviceable wiring, complete all as specified & directed. Note :- Two runs of cable4 Sqmm and One run of 2.5 Sqmm shall be measured as unit length.
M&L in repairs sub main wiring with 6.00 Sq mm single core multistrandred copper conductor PVC insulated FRLS and unsheathed cable passing through PVC concealed conduit and making good the distrurbed surface of wall inc 4 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire, including dismantling of old unserviceable wiring, complete all as specified & directed. Note :- Two runs of cable 6 Sqmm and One run of 4 Sqmm shall be measured as unit length.
M&L in replacement Earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 3 connected to Earthing test point all as specified or indicated including testing on completion Note : (i) Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover etc complete. (ii) Earth lead shall be up to 7.5 Mtr and rates are deemed to be included for GI pipe 15mm Light grade upto 7.5 mtrs for protection of earth wire 4.0 mm dia., including dismantling of old unserviceable earthing, complete all as specified & directed
S & F in replacement LED landscape light 9W W with die-cast aluminum housing designed for rugged outdoor usage & IP 65 protection, including dismantling of old unserviceable wiring, complete all as specified & directed.
mahalaxmi enterprises
M/s Chawariya Enterprises
M/S ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .