Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC D 47 MANORATH SOCIETY NEAR AMAR COMPLEX SAMA ROAD VADODARA 390024 | VADODARA | GUJARAT | 390024 | L1 | Accepted-AOC VALID AND ADMITTED | |
| 2 | L2₹19.1 L+₹80,651.20 (4.40%)Rejected-AOC | L2 | Rejected-AOC VALID AND ADMITTED | |
| 3 | L3₹19.1 L+₹80,875.50 (4.41%)Rejected-AOC | L3 | Rejected-AOC VALID AND ADMITTED |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Mar 2020, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2020_MES_325504_1
8500
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹40,000
Yes
19 Mar 2020
15 Feb 2020
12 Mar 2020
15 Feb 2020
7 Mar 2020
19 Feb 2020
15 Feb 2020 - 18 Feb 2020
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out soft/loose soil all as specified and as directed.
M & L for cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as specified and as directed.
M & L brick work with sub class "B" bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) all as specified and as directed.
M & L for rendering 15mm thick in CM (1:4 on fair faces of brick and concrete surfaces finiesh even and fair without using extra cement all as specified and as directed.
M&L for Hardcore of gauze n exc 63mm of broken stone or boulders, deposited spread and levelled n exc 15 cm thick,watered and rammed to a true surface all as specified and as directed.
M & L for 100mm thick PCC (1:4:8), type D-2 with using 40mm graded stone aggregate as in sub base flooring etc as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm height all as specified and directed.
M&L 100mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate) & spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green all as specified and as directed.
M & L for Forming 65mm deep x 10mm thick contraction (dummy joints), filled with sealing compound grade "A".
M & L for mild steel work confirming to Fe-290 Gde E-165 in angle iron posts & struts in fencing including cutting top to shape as directed, drilling holes, noteching for wire , etc. and including flat iron filletes for securing wire mesh or fence etc. including all necessary bolting riviting etc complete.
S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Returning filling including spreading, leveling, watering and wel ramming in layers n.exc 25 cm in soil complete all as specified and directed
M & L for preparation of new plastered surface of wall and applying three coats of white wash all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness (below or above ground level)
Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically provided for drain
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of old broken Fencing/barbed wire, wire mesh, and rolling/winding and removing from site.
M & L for cement concrete 1:2:4, type B2 (using 20 mm graded stone aggregate) in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as directed.
M & L for reinforcement cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) in columns, pillars, piers, posts and struts etc., complete as directed.
M & L for cement concrete 1:3:6 mix, type C1 (using 20mm stone aggregate) as in coping etc. complete as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spece and binder spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Used & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc., all as directed.
Used & waste form work to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surface of concrete for square or rectangular or polygonal shape all as specified.
S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
M & L for broken glass coping in 25 mm thick rendering in cement mortar 1:3 on top of walls all as specified and directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and fair (without using extra cement)
M & L for preparation of new plastered surfaces and applying two coats of cement base paint over one coat of primer maching to existing of wall surface.
M&L preparing new/old plastered surfaces of wall and applying 1 to 1.5 mm thick layer of Birla/J K Wall care Putty all as specified and directed. .
Roughning of old unservicable PCC floor surface by picking, chipping and wire brush sweeping clean and washing down with water to remove dust outside to make it suitable for laying floor tile
M & L for 20 mm thick machine cut green marble stone as in floor, steps (in single piece), cooking platform etc laid over 15 mm thick cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including cement mortar 1 : 4 complete all as specified and as directed.
M & L for 20 mm thick machine cut green marble stone as in riser of steps in single piece , skirting, dado and pillar laid over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 4 complete all as specified
Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm , as in floors etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 Note:Tile pattern and decoration shall be as decided by Engineer-in-charge
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm, as in skirting/dado etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including rendering or bedding layer of mortar 10 mm thick for fixing/laying with CM 1:4 Note:Tile pattern and decoration shall be as decided by Engineer-in-charge
M & L for Glazed ceramic coloured walls tiles in vertical surfaces 300x450x 6mm to 7 mm thick set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles Note:Tile pattern and decoration shall be as decided by Engineer-in-charge)
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for drain
Cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges.
Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc.
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
M & L brickwork with sub class ‘B’ bricks straight or curved to any radius in half brick thick walls built in CM 1:4 all as specified and as directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
Rendering 10 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:4 for finished even and smooth (without using extra cement)
Supply only Internal water proofing compound all as specified and directed.
M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of 1 to 1.5mm average thick birla/ equivalent wall care putty and one coat of primer. (Note : Putty shall be measured and paid separately under relevant Item)
M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distamper over a coat of 1 to 1.5mm average thick birla/ equivalent wall care putty and one coat of primer. (Note : Putty shall be measured and paid separately under relevant Item)
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash matching to existing wall surface.
M & L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of primer on external wall.
M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall applying two coat of cement base paint on external wall
M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M & L for preparing old plastered surfaces of ceiling and applying two coat of white wash on ceiling to match the existing surfaces.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sq m but n.exc 4.00 Sq m each
Taking down shutter of any description exc 1 Sqm and n.exc 2 Sqm each
Refixing of door shutter exc. 1 Sqm and n.exc. 2 Sqm each in same opening.
M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE.
S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitered and moulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats.
M & L for tarring to small articles like hold fast etc area tarred n.exc 0.10 Sqm Each
S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F of Powder coated aluminium window/ventilator shutters, side hung/sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws and grill etc as per manufactures instruction & trade pactee.
S&F 4.00mm thick figured glass, pin head type and glazing with rubber beading or with glazing clips, all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and as directed.
S & F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolt, if required hooks(stay), heavy for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps hold fasts, wall ties, hooks for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 310-O or Fe 410-O
M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/PVC door frame with screw complete all as specified and directed.
S&F Butt hinges 75mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 all as specified and as directed.
S & F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
S & F in repairs 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
S & F 125 mm size extruded aluminium alloy handles, fabricated type anodised all as specified and as directed.
S & F 300 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
S & F 250 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
S & F 2nd class HW Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each
S & F solid PVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade. The door frame shall be tied to the wall using 75/100mm long MS screw as directed .
S & F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete all as specified and directed.
S & F 125 mm aluminium alloy handles, cast type anodised all as specified.
S & F 150mm aluminium anodised barrel tower bolts of extruded section and fixed.
S & F 100 mm size Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
S & F in repairs 20mm dia aluminum anodised tubular curtain rod as directed
S & F in repairs 20mm dia aluminium anodised bracket for curtain rod as directed
S & F in repairs 20mm dia brass chrom plated tubular towel rail complete.
S & F 25 mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on one side and the other side covered with decorative face veneered with teak wood lipping/ frame to match 3 to 6mm thick
S & F in repairs factory made 18 (+ 0.7 mm) thick PVC sheet one sided prelaminated sheet cabinate shutters and interior. 18mm (+ 0.7 mm) thick sheet of density 600 kg/m3 bent at 90 degree and finished all edges at all level for making edges, Lipping/bending or 0.5mm thick PVC sheet lipping at ll four edges using bonding tape etc complete all as per directed.
S & F for pressed steel doors frame (thickness of MS sheet 1.25mm) with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, stainless steel hinges, lock strike plate, etc., complete, as specified and as directed. Note :- Filling of hollow of frame with plain cement concrete anstainless steel hinges of 100 mm size will be measured and paid saperately under respective items.
S & F for pressed steel doors frame with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, stainless steel hinges, lock strike plate, etc., complete, as specified and as directed. Note :- Filling of hollow of frame with plain cement concrete anstainless steel hinges of 100 mm size will be measured and paid saperately under respective items.
M & L for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in filling hollow portion of pressed steel door frame
M & L for preparing new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M & L for preparing old steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint to match the existing surfaces.
M & L for preparing old wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint to match the existing surfaces.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
S & F 16 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F 15mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
S & F 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
S & F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Dismantling cast iron pipes, jointed in cement mortar for 100 mm bore
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
Dismantling cast iron pipes, jointed in cement mortar for 75 mm bore
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) bends any radius all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) bends any radius with oval access door all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) bends any radius all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) bends any radius with oval access doors all as specified and as directed.
S & F in repair 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed
S & F in repairs 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal or with parallel branches with access door all as specified and as directed
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 110mm bore pipe all as specified and as directed
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed
S & F 110mm PVC (SWR) vent cowl all as specified and as directed
S & F 75mm PVC (SWR) vent cowl all as specified and as directed
S & F in repairs 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule
S & F in repairs stop valves/Angle valve15mm bore fancy type chromium plated screwed both ends for iron pipe or for unions and fixed
S & F in repair concealed stop cock fencing type with sheet flange cast copper alloy, scrwed down high precure with round operating knob for 15 mm bore pipe bore and fixed all as specified and directed.
S & F in repairs 25mm dia bore gun-metal,globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed
S & F 125mm dia chromium plated shower rose with swivel joints including fixing to GI union complete
S & F CP wall mixer three in one system for mixing hot and cold wather screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed. Make Jaquar Cat part No QQT-7217 or equivelent make.
Supply and fixing CP Centre hole Wash Basin mixer three in One 15 mm bore pipe complet all as specified. Make jaquar Cat part No QQT-7167B or equivelent make.
S&F 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waster pipe
Dismantling of water storage tank of any capacity.
S & F 500 Ltrs Rotational moulded polyethylene water storage tanks double layered (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S & F in repairs Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed
S&F in repairs vitreous China squatting pan of Orissa pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including P or S trap etc and provision of lime concrete bedding complete all as specified and as directed.
S&F in repairs PVC flushing cistren low level, 10 ltr capacity with syphonic action type ball valve. Incl inlet ball valve, PVC band 32mm complete all as specified.
S & F 110mm PVC (SWR) WC connector with lip ring all as specified and as directed.
S & F 110mm PVC (SWR) WC connector bent type to fit WC outlet all as specified and as directed.
S & F 110mm PVC (SWR) junction single, (Single T, 'Y' type) equal or unequal all as specified and as directed.
S & F 75mm PVC (SWR) junction single, (Single, 'Y' type T) equal or unequal all as specified and as directed.
S&F in repair vitreous china Wash hand basin, white , flat back size 550x400 mm except taps, CP waste coupling but incl brackets all as specified. Make cera/Hindware
S & F 32 mm dia stainless steel waste coupling for wash hand basin all as specified and directed. Make : Prayag or equivalant.
S & F PVC connections 15mm size with PTMT nuts of length 450mm
S & F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm including suitable waste coupling and waste pipe. (Make : Nirali (Elegance), blue star, Jayana, Prayag or equivalent
Supply & Fix of stainless steel wall mounted plate rack of size 880x220X 880 mm and thickness of sheet not less than 0.50mm with provn for keeping plates and other crockery fixed with screw and rawal plug etc on wall complete all as specified and as directed
M & L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection, chajja, fins,facia, roof bands etc and making good with PCC (1:11/2; :3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in any position finished the surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement) if required complete and applying three coat of white wash/two coat of cement base pint to match with the existing surface as directed by the Engr- in -Charge .
M&L for Providing precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to matchcomplete all as specified and directed.
M & L for 100 mm thick PCC 1:4:8 mix type D2 using 40mm graded crushed stone agg as in sub base as in floor.
M&L for machine pressed precast concrete (rubber moulded) coloured interlocking paver block any shape & size conforming to IS 15658-2006 of 60mm thickness, M-35 grade, bedded and jointed with gray cement and pigment over 30mm thick sand cushioning (sand cushion paid separately) complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6 mix type C2 using 40 mm graded aggregate as in plinth protection and paving finishing cone surface even and smooth without using extra cement
M & L for machine cut kota stone slab flooring 20 - 25mm thick set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6
M&L for sunken treatment of WC/Bath with polymeric membrance (APP based) with non woven polyster mat as reinforcement including water tightness test with filling of water for continuous 48 hours with following :-
Demolition of existing PCC /lean concrete including floor tiles and removing rubbish off the premises.
M&L for 15 mm thick plaster in sunken portion with CM 1:3 mixed with water proofing compound @2% by weight of cement plaster surface should be even and smooth without using extra cement all as directed. Note . (WPC will be measured and paid separately).
M&L for providing & laying APP based polymeric membrance of weight of 3 kg/sqm with non woven polyster fibre as reinforcement over a coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm by torch application with side over laps & longitudinal joints over laps etc as per manufacturer instructions complete all as specified and as directed..
M&L for sunken portion filled with lean concrete 1:5:10 using brick/lime aggregate and finish the surfaces rough to receive sub base complete all as specified and as directed.
M & L for 25 mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate) with water proofing compound @3% by weight of cement for laying floor tiles. Note (WPC will be measured and paid separately).
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point
M&L for sand cushoning, to cable with river sand and punning to provide required cover for UG cables all as directed at site. Note: Punned thickness shall be measured and paid.
M&L brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying or fixing or passing through pipe,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 16 sq. mm 4 Core .
M&L for galvanized steel tubing light Grade of 40 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Dismantling and taking out submain wiring 2/3/4/6 wire of any size, segregating for material for reuse, making good disturbed surface of walls/floors to match with existing surface and taking out from site all as directed by Engineer-in-Charge.
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 19mm dia ISI marked and conduit accessories fixed on wall/ceiling /roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
One light/fan/bell point controlled by one switch 6 Amp one way
One 3 pin switch socket combination 6 amp on independent board.
3 pin switch socket combination on same board with other switches.
All as described as per item No 157 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
One light point controlled by two way switches
S/Fix MCB DB factory made IP 42protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed of following sizes:-
SPN 08 way
TPN 4 way
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB (DB will be measured and paid separately under respective items of sch A):-
MCB SPN 5 to 40 Amps.
MCB SP 5 to 40 Amps
MCB TPN upto 63 Amps
M&L switch piano flush type single pole, one way 6amp .
S & F switch piano flush type single pole, Two way 6amp
M&L switch socket combination 5 pin 6 amp.
M&L Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal.
Supply and fix fan regulator electronic type 100Watt 20V-50Hz as directed by Engr-incharge, Make: Ancho cat No 38660 or equivalent
S/fix ceiling rose 65x17mm three terminals .
S& F lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting along with 09watt LED Lamp of make : Philips/Bajaj/Wipro
M&L flush type bell push 6 amp duly marked for bell complete.
M&L Electronic ding dong bell AC 230V single pole
Concealed Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and PVC conduit with accessories shall be measured as one unit
Supply, Fixing, Testing and commissioning of 4' LED not less than 1X18W LED Batten with LED tube not less than 18 watt. Similar to Batten cat Part No.REGALBATTEN8UPTO 1X22wSSBSWH and LED tube light cat part No.CRYSTAL 1213T8DSTL18WLED865S GLASS of Make- Havells or equivalent in Make: Philips/ Wipro/CG
Supply, Fixing, Testing & Commsioning of IP66 & IK09 integral LED Bulk Head luminaire with housing made of Pressure Die Cast alumunium & Optical cover made of Opal Polycarbonate for glare free lighting . System Lumen Output of minimum 600 lumens. Power Consumption should not exceed 10W (Including Driver Loss). For Glare free lighting luminaire should be with Opal diffused Polycarbonate. Make : Philips/Wipro/CG
Supply, Fixing, Testing & Commisioning of 2' 10W Mirror LED Batten with system lumen output of 1000 lumens. System Efficacy should be > 85lm/ W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Housing of luminaire should made of die cast alumunium & mounting on two PVC square boxes of size not less than 75mm X 75mm complete including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete all as specified & directed. Make- Philips, Model-BN021 LED 10S-6500 PSU GR S1 or equivalent in Wipro/Havells
S & F wall security light LED type complete with GI bend 1.2 mtr and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified by Engr-In-Charge. CAT Part No.LSTO-25-CDL 25watt of Make CG or its equivalent in Phillips/Wipro.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, CI Cover with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe15mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply and fixing ceiling fan 1200 mm sweep BEE 5 star rated including fixing of down rod and connection complete with & including provision of flexible three core PVC insulated multi-stranded copper conductor cable of size 0.50 sq mm from ceiling rose/connector to fan complete all as specified and directed. Make : Crompton Greaves or equivalent in Bajaj/Orient/Usha Note: Old UNSV ceiling fans will be deposited to AGE E/M office
M&L for making hole in existing wall of 230mm thickness, suitable for housing of 250/300 mm sweep Exhaust fan complete including grouting of 04 Nos bolt fasteners, PCC work etc including making good disturbed surfaces
S&F of Exhaust fan 225/250 mm sweep, aluminum rust proof body & blades, with louvers for protection from birds, 230 Volt AC supply, rated power input not more that 45watt, connecting up including provison of cable from ceiling rose to fan. Make : Crompton Greaves/BAJAJ/HAVELLS Note: Old UNSV ceiling fans will be deposited to AGE E/M office
S & F 25 litre storage water heater, rated power consumption 2000W, current leakage protection device, multi functional safety valve, high precision thermostat control, preset thermal output, high working pressure 0.8MPa ideal for high rise building, vertical mounting, Power consumption not more than 2000watts, Operating voltage 230 volts including all fittings complete & provision of flexible three core PVC insulated multi-stranded copper conductor cable, similar to model Number Puro Turbo 25L (Havells), GHWAPTTIV025 or equivalent in Bajaj/Racold/V-Guard
Supply, fixing, testing & commissioning of exhaust fan 300 mm sweep 1400 RPM with minimum airflow/air delivery 1710 Cmh, totally enclosed heavy duty motor, die cast aluminium rotor mounted on double ball bearing, IP-55, polarity-4, 230 Volt AC supply (single phase), rated power input not more that 90watt, with louvers and connecting up including provison of PVC insulated overall PVC sheathed copper conductor cable from ceiling rose to fan. Make : CG/Bajaj/Havells or equivalent. Similar to Crompton Greaves model No EXHD300-4-1 Note: Old UNSV ceiling fans will be deposited to AGE E/M office
Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for LAN and TV Socket
PVC Junction boxes (1 to 4 way)
S& F PVC insulated overall PVC sheathed twin core 1 pair of size 0.51mm as per ITD specification cable with copper conductor suitable for telephone drawn through conduit complete all as specified as directed
S& F PVC insulated overall PVC sheathed cable with copper conductor of size RG-8 suitable for cable TV connection drawn through conduit complete all as specified and directed
S & F RJ11 telephone outlet with shutter similar to Schneider cat Part No P4011_DG
S & F TV socket similar to Schneider cat Part No P4500_DG
Nirmal Constructions
RAJENDRASINH B THAKOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .