Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.8 LAccepted-AOC D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹28.7 L+₹1.7 L (6.31%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹36.7 L+₹9.7 L (35.8%)Rejected-Finance D NO 35 14 13 1 RP PETA GAVARA KANCHARAPALEM VISAKHAPATNAM 530008 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530008 | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹36.7 L+₹9.8 L (36.1%)Rejected-Finance | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹37.0 L+₹10.0 L (37.2%)Rejected-Finance | 5 | Rejected-Finance Not L-1 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
14 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIRS MAINTENANCE OF COOLING APPLIANCES UNDER AGE EM OF GE ND VISAKHAPATNAM
2021_MES_451600_1
8962/GEND
Open Tender
Miscellaneous Works
Item Rate
270 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE ND Visakhapatnam
₹66,000
Yes
10 Aug 2021
15 Jun 2021
19 Jul 2021
15 Jun 2021
14 Jul 2021
30 Jun 2021
60 days
Amount
M & L for taking out the defective / burnt out compressor from Split type air conditioner of 1.5 ton capacity from its position and providing new compressor Rotary / Reciprocating of approved make best suitable for the unit, cleaning the refrigeration system thoroughly with CTC, leak testing, vaccumisation, charging with new refrigerant gas suitable for the unit testing for its effective functioning, connecting up all electrical connections and finally testing and commissioning including cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, CTC, refrigerant gas, CO2, etc. as required for the job complete all as specified and directed. [Notes: Quoted rate is deemed to be inclusive for cutting, brazing, sealing the refrigeration tubing, replacement of stainer, CTC, refrigernat gas including transportation charges from site to workshop and back] [Make: Blue Star / York / Kirloskar / Carrier / Daikin / Trane / Hitachi]
All as per item No. 1 above but for 2.0 Ton capacity floor mounted / tower model Split type AC Conditioner
All as per item No 1 here-in-before but for 3.0 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts
All as per item No 1 here-in-before but for 5.5 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts
All as per item No 1 here-in-before but for 7.5/8.5 ton capacity floor mounted / tower model cassette type air conditioner three phase 415 Volts
M & L for compressor suitable for refrigerator upto 400 litres capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: LG / Whirlpool / Samsung / Kirloskar / Godrej]
M & L for compressor suitable for water cooler upto 150 litres capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: LG / Whirlpool / Samsung / Blue Star / Godrej / Kirloskar]
M & L for compressor suitable for Deep freezer of any capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as directed. [Make: LG / Whirlpool / Kirloskar / Blue Star / Godrej]
Supply and charging of refrigerant gas suitable for window / split air conditioners / water collers / refrigerators complete all as directed. [Make: Floron / Mafron / Refron / National]
M & L for leak testing with N2 gas of entire refrigeration system, rectification of leaks by welding / brazing and pressure testing as per the standards and holding the pressure for 24 Hrs and observe for any pressure drop in the system including evacuation with vaccum machine complete all as directed.
Supply and replace unserviceable blower fan motor for hot air upto 2.0 Ton capacity Split air conditioner with new fan motor double shaft type suitable for air conditioners 800 to 1250 RPM including testing complete all as directed. [Make: Magic / National / CG / Usha]
Supply and replace unserviceable blower fan motor for water cooler upto 150 Lit capacity complete all as directed. [Make: Magic / National / CG / Usha]
Supply and replace unserviceable blower fan blade for hot air / cool air suitable for split type air conditioner upto 2.0 Ton capacity, balancing for smooth rotation in the casing and testing complete all as directed. [Make: Magic / National / CG / Usha]
Supply and replace unserviceable blower fan blade for hot air / cool air suitable for floor mounted / tower model split type air conditioner for 3.0 Ton capacity, balancing for smooth rotation in the casing and testing complete all as directed. [Make: Magic / National / CG / Usha]
Supply and replace unserviceable blower fan blade for water cooler upto 150 Lit capacity balancing for smooth rotation in the casing and testing complete all as directed. [Make: Magic / National / CG / Usha]
Supply and replace old defective running capacitors with new capacitors 45 mfd rating suitable for 1.0/1.5 Ton capacity air conditioners complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective running capacitors with new capacitors 50 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective running capacitors with new capacitors 4 mfd rating suitable for water coolers and fan capacitors of Split AU units complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective running capacitors with new capacitors 10 to 20 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective running capacitors with new capacitors 25 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective starting capacitors with new capacitors 80-100 mfd rating suitable for 1.0/1.5 Ton capacity air conditioners/ water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective starting capacitors with new capacitors 100-120 mfd rating suitable for 2.0/3.0 Ton capacity air conditioners/ water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective starting capacitors with new capacitors 40-60 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace old defective starting capacitors with new capacitors 60-80 mfd rating suitable for water coolers complete all as directed. [Make: Havells / Keltron / CG / Usha / Unistar / Tibcon]
Supply and replace unserviceable condensation coil upto 2.0 Ton capacity window / split type air conditioner including testing complete all as directed.
Supply and replace unserviceable condensation coil for 3.0 Ton capacity window / split type/tower/cascade air conditioner including testing complete all as directed.
Supply and replace unserviceable condensation coil for 5.5 to 7.5 Ton capacity window / split type/tower/cascade air conditioner including testing complete all as directed.
Supply and replace unserviceable condensation coil upto 150 Litres capacity water coolers including testing complete all as directed.
Supply and replace unserviceable condensation coil upto 400 Litres capacity Refrigerators including testing complete all as directed.
Supply and replace unserviceable condensation coil suitable for deep freezers of any capacity including testing complete all as directed.
Supply and replace unserviceable Evaporator coil upto 3.0 Ton capacity window / split type air conditioner including testing complete all as directed.
Supply and replace unserviceable contactor single phase with new contactor suitable for Split air conditioners upto 2.0 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH]
Supply and replace unserviceable contactor three phase with new contactor suitable for Split air conditioners upto 7.5 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH]
Supply and replace unserviceable Relay suitable for Split AC upto 3.0 Ton capacity complete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH]
M & L for servicing of Air conditioners of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, grills, etc and checking of all the electrical connections, etc complete all as directed.
M & L for servicing of water coolers, Refrigerators and deep freezers of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, etc and checking of all the electrical connections, etc complete all as directed.
M & L for rewinding of unserviceable blower / fan motor of any capacity Split type AC including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing complete all as directed.
All as per item No. 37 above but for Water coolers of any capacity.
All as per item No. 37 above but for Refrigerators of any capacity.
Supply and replace air filters, non woven, synthetic, high efficiency washable type suitable for 1.5 / 2.0 Ton capacity Air conditioners complete all as directed.
Repairs to defective printed circuit board of Split AC / Window AC / water cooler / refrigerator of 230 Volts single phase any capacity complete all as directed.
Supply and replace unserviceable Electronic Printed Circuit board for outdoor unit of inverter type Split AC of 1.5/2.0/3.0 Ton capacity complete all as directed. [Make: Blue Star / York / Kirloskar / Carrier / Daikin / Trane / Hitachi]
Supply and replace unserviceable Electronic Printed Circuit board for indoor unit of inverter type Split AC of 1.5/2.0/3.0 Ton capacity complete all as directed. [Make: Blue Star / York / Kirloskar / Carrier / Daikin / Trane / Hitachi]
Supply and fix copper tubing 24 SWG of size 5/8" along with tubular insulation suitable for Split AC complete all as specified and directed.
Supply and fix copper tubing 24 SWG of size 1/2" along with tubular insulation suitable for Split AC complete all as specified and directed.
Supply and fix copper tubing 24 SWG of size 1/4" along with tubular insulation suitable for Split AC complete all as specified and directed.
Supply and replace PVC drain pipe of 20mm bore complete all as specified and directed by Engineer-in-Charge. [Make: KISAN / JAIN IRRIGATION / FINOLEX / SUPREME / PRINCE]
Supply and replace Split AC Valves made of high grade free cutting brass and copper for pipe of size 1/2", 1/4", 3/8" and 5/8" complete all as specified and directed.
Supply and replace electronic remote control with hand set with wall stand suitable for Split AC of 1.5 / 2.0 Ton capacity of existing make and model complete all as directed.
Supply and replace copper capillary tube suitable for Split AC of 1.5 / 2.0 Ton capacity complete all as directed.
S & F sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH]
M & L for cutting and removing rusted steel body of Split AC / Window AC / Water coolers of any type and welding new MS sheet of suitable gauge including necessary bending as required and applying two coats of synthetic enamel paint over a coat of primer complete all as directed. [Make: ASIAN / SHALIMAR / BERGER / J & N]
Repairs to Voltage stabiliser including replacing the defective parts like relay, bridge, transformer, glowing lamps and making serviceable for automatic operation, for input variation between 170 to 250 volt and output voltage stabilised at 230 volt with accuracy of + 2.5% of capacity 4.0 / 5.0 KVA complete all as directed.
Supply and replace lift/push cock chromium plated brass of 15mm size suitable for water cooler of capacity 40/80 Litres complete all as directed.
Supply and replace thermal insulation for indoor to outdoor copper pipe suitable for split type AC of any capacity complete all as directed.
Supply and replace Thermostat suitable for water cooler of capacity upto 150/150 Lit complete all as directed. [Make: Sporlon / Floron / U Flow / Honeywell / Siemens / Danfoss]
Supply and replace Overload protector suitable for water cooler of any capacitycomplete all as directed. [Make: L&T / C&S / SCHNEIDER / SIEMENS / ABB / BCH]
Supply and replace indoor unit of split type Air conditioner 1.5 Ton capacity suitable for existing outdoor unit complete all as directed. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER]
Supply and replace indoor unit of split type Air conditioner 2.0 Ton capacity suitable for existing outdoor unit complete all as directed. [Make: BLUE STAR / HITACHI / DAIKIN / CARRIER]
Supply and replace stainless steel drain tray made of SS 304 suitable for water coolers of any capacity complete all as directed.
Supply and replace gun metal gate valve 15mm dia for water cooler complete all as specified
S & F GI tubing 15mm dia medium grade with all fittings and fixtures complete as in water coolers complete all as specified. [Make: JINDAL / TATA / ZENITH / PRAKASH]
Supply and replace PVC copper conductor cable of size 3 core 4 Sqmm for connecting indoor unit to outdoor unit complete all as directed. [Make: Finolex / Nicco / Havells / KEI / Polycab / RR Cabel Ltd]
M & L for core cutting hole for passing AC drain pipe and copper tubing from indoor unit to outdoor unit in any type of wall including making good to the disturbed surfaces to match with adjoining surfaces complete all as directed.
Supply and replace swing motor suitable for split / tower AC of any capacity complete all as directed
S & F Pre-fabricated brackets (stands) for outdoor units of Split AC units made of heavy duty GI Sheet thick High Grade Anti Corrosive Metal Plates duly Powder Coated for rust prevention complete all as specified and directed by Engineer-in-Charge
M & L for dismantling of existing Split AC unit of any make and capacity (indoor and outdoor unit) from any position after disconnecting from main supply including shifting and installing the same at new location duly restoring the refrigerant gas and connecting with electric supply and testing for its smooth working complete all as directed by the Engineer-in-Charge
S & F voltage stabiliser for automatic operation, single phase naturally air cooled, copper wounded as per IS 8448-1989 with digital display, wall mounted, indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilsed at 230 Volts with accuracy of + 2.5% and of capacity 4 KVA complete all as spcified and directed. [Make: V-Guard / Volina / Aplab / Servo]
Supply and replace HP/LP switch of 7.5/8 TR split/ tower AC unit of any make complete all as directed
Supply and replace fan guard/ grill suitable for Split AC outdoor units complete all as directed
Supply and replacement of connector suitable for Split AC units for connecting wire / cable from indoor unit to outdoor unit complete all as directed
ANAND ENTERPRISES AND ENGINEERS
M/S CHANDRA ENGINEERS AND CONTRACTORS
M/s Chandu Lavanya Engineers Contrctors
POWERMECH INDUSTRIAL ENTERPRISES
pavantejaklimmaat enterprises
LAKSHMI SAI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .