| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC TOWN PADUMBASAN P O TAMLUK P S TAMLUK PURBA MEDINIPUR 721636 | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721636 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.8 L+₹23,331.12 (3.09%)Rejected-AOC WARD NO 12 TAMLUK PARBATIPUR TAMLUK PURBAMIDNAPUR 721636 | TAMLUK | PURBA MEDINIPUR | WEST BENGAL | 721636 | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.8 L+₹28,717.50 (3.80%)Rejected-AOC | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Pranay Kumar Sinha L1 | MAHAKALI ENGINEERING WORKS L2 | ACAM CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Erection of DP structure using 8 Mtr long PCC pole 33 KV LA with concrite foundation of PCC pole with Cable [L.S.] | 1 | NOS | 11,640 ₹11,640 Lowest | 12,000 ₹12,000 | 11,640 ₹11,640 Lowest |
| 2.00 | Erection of 4-Pole structure usiug 8 m long P.C.C Pole 33
KV H.L/L.L. lsolator support, with concrete foundation of
PCC Pole | 4 | NOS | 17,460 ₹69,840 Lowest | 18,000 ₹72,000 | 18,000 ₹72,000 |
| 3.00 | Erection of 42 KV Class Gapless L.A. [L.S.] | 3 | NOS | 1,100 ₹3,300 Lowest | 1,144.24 ₹3,432.72 | 1,250 ₹3,750 |
| 4.00 | Erection of 11 KV Class Gapless L.A. | 1 | SET | 329 ₹329 Lowest | 339 ₹339 | 340 ₹340 |
| 5.00 | Erection of 33 KV C.R. type Isolator with (H.L) [L.S.] | 2 | SET | 6,100 ₹12,200 Lowest | 6,288.71 ₹12,577.42 | 6,259 ₹12,518 |
| 6.00 | Erection of 33 KV C.R. type Isolator with (L.L) [L.S.] | 2 | SET | 6,036 ₹12,072 Lowest | 6,170 ₹12,340 | 6,036 ₹12,072 Lowest |
| 7.00 | Erection of 33KV VCB (to be suplied by WBSEDCL) and its
allied structure as supplied by manufacturer and foundation as per the following specification [L.S.] | 1 | NOS | 17,337 ₹17,337 Lowest | 17,873 ₹17,873 | 17,337 ₹17,337 Lowest |
| 8.00 | Erection of 33 KV CR Individual feeder Control Panel with
DirectionaI Relay | 1 | NOS | 2,02,322 ₹2,02,322 Lowest | 2,08,579.8 ₹2,08,579.8 | 2,05,000 ₹2,05,000 |
| 9.00 | Erection of Shunt Trip Indoor type 11 KV 350/800/1250
Amp VCB complete [L.S.] | 5 | NOS | 6,430 ₹32,150 Lowest | 6,628 ₹33,140 | 6,759 ₹33,795 |
| 10.00 | RTCC PANEL FOR 6.3 MVA TRANSFORMER [L.S.] | 1 | NOS | 9,700 ₹9,700 Lowest | 10,000 ₹10,000 | 9,852 ₹9,852 |
Tender Value
₹7.8 L
EMD Value
₹15,563
Closing Date
9 Dec 2025, 2:00 pmClosed
DIVISIONAL MANAGER HALDIA DIVISION
HALDIA DIVISION
NIT FOR BAY EXTENSION WITH CAPACITY AUGMENTATION OF THE AMTALIYA SS UNDER HALDIA DIVISION
2025_WBSED_949183_1
HDD/WBSEDCL/2025-26/11/2059
Open Tender
Miscellaneous Services
Item Rate
AMTALIYA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹15,563
HALDIA DIVISION
14 Jul 2026
14 Nov 2025
11 Dec 2025
17 Nov 2025
9 Dec 2025
19 Nov 2025
18 Nov 2025
Amount
Erection of DP structure using 8 Mtr long PCC pole 33 KV LA with concrite foundation of PCC pole with Cable [L.S.]
Erection of 4-Pole structure usiug 8 m long P.C.C Pole 33 KV H.L/L.L. lsolator support, with concrete foundation of PCC Pole
Erection of 42 KV Class Gapless L.A. [L.S.]
Erection of 11 KV Class Gapless L.A.
Erection of 33 KV C.R. type Isolator with (H.L) [L.S.]
Erection of 33 KV C.R. type Isolator with (L.L) [L.S.]
Erection of 33KV VCB (to be suplied by WBSEDCL) and its allied structure as supplied by manufacturer and foundation as per the following specification [L.S.]
Erection of 33 KV CR Individual feeder Control Panel with DirectionaI Relay
Erection of Shunt Trip Indoor type 11 KV 350/800/1250 Amp VCB complete [L.S.]
RTCC PANEL FOR 6.3 MVA TRANSFORMER [L.S.]
Erection of 33KV C.T
Installation of CT Junction Box
Erection of single WFB Pole 13 mtr with foundation for sgield wire [L.S.]
Drawing of Shielding wire by using ACSR 50 Sq. mm. after fixing the bracket on Rail Pole with taking proper sag as per toy out drawing.
Execution of 33 KV shielding earth by fixing of 6.1. earth electrode Fixing with wielding & interconnection between ground earth by G.I. Stay wire 7/ 10 or 7/12 SWG with
Fixing of 33 KV Disc lnsulator (to be suplied by WBSEDCL)
Fixing of 33 KV Pin insulator (to be suplied by WBSEDCL)
HT Stay grouting
Earthing of spike
LAYING & JOINTING OF 1.1 KV 4C X 2.5 SQ.MM COPPER CONTROL CABLE WITH SUPPLY OF CABLE BUGS, GLANDS, TAPES, SOCKETS ETC
LAYING & JOINTING OF 1.1 KV 8C X 2.5 SQ.MM COPPER CONTROL CABLE WITH SUPPLY OF CABLE BUGS, GLANDS, TAPES, SOCKETS ETC
LAYING & JOINTING OF 1.1 KV 12C X 2.5 SQ.MM COPPER CONTROL CABLE WITH SUPPLY OF CABLE BUGS, GLANDS, TAPES, SOCKETS ETC
Laying of 11 KV, 3- Core, 300 mm² cable
Making & fixing of end termination joint IN/OUT - DOOR type for Cable 11 KV XLPE 3X300 Sq mm
Earthing Arrangment Sub - station
Erection of CT Structure
Fitting & Fixing of Compression Joint for wolf Cond.
Fitting & Fixing of Jumper for wolf Cond.
Stringing & Sagging of ACSR Panther 200 Sq mm Dog (3 Wire)
Supply of G.I. Pipe 40 mm, 3 Mtr Long (TATA/Jindal)
Erection of CT Structure
Erection of Cable Structure
Supply of G.I. EYE BOLT
Supply H/W fittings for ACSR PANTHER Suitable for Compressor joint
Supply of Isolator Pad to Bi - Metallic Connector for Panther suitable for compressor Joint
Supply for T - Connector for Panther Suitable foe Compressor Joint
Painting of Switchyard [L.S.]
Earthing Labour [L.S.]
Up rooting of Rail Pole Return to store in a good condition
MAHAKALI ENGINEERING WORKS (BID ID -7573091)
ACAM CONSTRUCTION (BID ID -7574537)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.60 MB
BOQ
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .