Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.5 LAccepted-AOC D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹35.5 L+₹2.6 L (8.04%)Rejected-Finance | 2 | Rejected-Finance Other than lowest bidder | |
| 3 | 3₹37.9 L+₹5.0 L (15.3%)Rejected-Finance | 3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
1 Jun 2020, 6:00 pmClosed
GE P NAVY KALINGA VISAKHAPATNAM
GE P NAVY KALINGA VISAKHAPATNAM
Provision of storm water drain near main gate, civilian community hall and recreation centre at NAD Polycarbonate corrugated sheet shed near ships galley and As and As to senior sailors dining hall P43A at Naval station Bheemunipatnam
2020_MES_341040_2
CA No.GE (P)/N/K/TOKEN/8704 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
INS KALINGA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
GE P NAVY KALINGA
₹78,000
Yes
26 Jun 2020
14 May 2020
2 Jun 2020
14 May 2020
1 Jun 2020
14 May 2020
Amount
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in complete all as HARD/DENSE soil complete all as specified and as directed by the Engineer-in-Charge.
All as per Sl Item No. 1 above but depth exceeding 1.5 m but not exceeding 3.0 m.
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC design mix M30 as in footings, plinth beams and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC design mix M30 a as in columns and pillars complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of form work to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of form work to sides of columns and pillars for for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
S&F reinforcement TMT steel bars of 10mm dia. and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia. or securing with clips or welded complete all as specified and as directed by the Engineer-in-Charge.
All as per item No.8 above but 5mm dia. and over upto and including 10mm dia. as in stirrups, spacers and binders.
M&L for brickwork with fly ash bricks, straight or curved on plan n. exc. 6m mean radius, built in cement mortar 1:6 complete all as specified and directed by the Engineer-in-Charge.
M&L for rendering 10mm thick with CM 1:6 on fair faces of brick work or concrete surfaces, finished fair and even complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick in two layers on external brick masonry surfaces or concrete surfaces, first coat 10mm thick in CM 1:6 and second coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturer's instructions finished fair and even complete all as specified and as directed by the Engineer-in-Charge. Note: WPC will be measured and paid seperately.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
M&L for preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion over one coat of primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying three coats of white wash on walls complete all as specified and as directed by the Engineer-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality-A complete all as specified and as directed by the gineer-in-Charge.
S&F mild steel angles, bars, flats, etc as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins, bolt and nuts and similar small articles confirming to Fe 410 -O or Fe-310-O complete all as specified and as directed by the gineer-in-Charge.
M&L preparation of new or previously untreated steel surfaces of any description, n. exc. 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed by the Engineer-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for anodised powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F anodised powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws with locking arrangement etc. complete (minimum thickness of powder coating 50 micron) all as specified complete all as specified and directed by the Engineer-in-Charge.
S&F anodised powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated on both sides with decorative choice lamination and fixed to aluminium frame work of doors complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm size aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F door closer hydraulically regulated of extruded aluminium section, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
S&F 5.5 mm thick plain sheet glass, ordinary quality in square exc. 0.5 sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F of aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
S&F powder coated aluminium grill (Design DG-117, 10 mm thick of Decogrill or equivalent make as approved by GE) fixed to aluminium frame work shutters (minimum thickness of powder coating 50 micron) including 'F' sections complete all as specified and directed. complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25cm complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material/Soil to a distance exc.1.5 Km but not exc 5 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n. exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by the Engineer-in-Charge.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B2 (Using 40mm graded stone aggregate) as in flooring/hardstanding and finishing the concrete even and smooth without using extra cement complete all as specified and as directed by the Engineer- in-Charge.
Excavating post holes or similar holes, each not exceeding 0.5 Cu. m, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distence not exceeding 50m and depositing where directed.
M&L for plain cement concrete 1:2:4 type B2 (Using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F mild steel screw bolts 12mm neck dia. (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n. exc. 5cm long complete all as specified and directed.
S&F polycarbonate corrugated sheet 2 mm thick of any colour as in roof covering/cladding to wall, fixted with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Demolition of unreinforced cement concrete in ground floor and pavings not exceeding 15cm thickness (Below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description exc. 1 Sq.m. but n. exc. 2 Sq.m. each complete all as specified and as directed by the Engineer-in-Charge.
Taking down Chowkhats or frames with shutters (with out taking off shutter from frame) not exc 1.5 sq. m each complete all as specified and directed.
Taking down Chowkhats or frames with shutters (with out taking off shutter from frame) exc 1.5 sq. m but n.exc 4.0 sq.m each complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and as directed.
M & L for second class plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
S & F second class hardwood 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
S & F second class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F 125 mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F 100mm size stainless steel butt hinges complete all as specified and as directed by the Engineer-in-Charge.
S & F of 200mm aluminium anodised,barrel tower bolts of extruded section complete all as specified and directed.
S & F of 150mm aluminium anodised,barrel tower bolts of extruded section complete all as specified and directed.
S & F 150mm size aluminium handles, cast type,anodised complete all as specified and directed.
S & F 125mm size aluminium handles, cast type,anodised complete all as specified and directed.
S & F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) (minimum thickness of powder coating 50 micron) complete all as specified and directed.
S&F 5.0 mm thick plain sheet glass, ordinary quality in square exc. 0.5 sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares n. exc. 0.5 Sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
M&L for 25mm thick PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C2, (Using 40mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L for non skid/matt finish ceramic tiles 7 to 8mm thick and size of each tile 600 x 600 mm in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid/matt finish ceramic tiles 7 to 8mm thick and size of each tile 600 x 100 mm as in skirtings etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over a backing coat of 15mm thick in CM 1:4 for laying tiles complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid/matt finish ceramic tiles 7 to 8mm thick and size of each tile 400 x 400 mm in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for glazed ceramic tiles in vertical surface like skirting/dado, 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match for joint free over a backing coat 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs stainless steel pipe 25mm dia. curtain rod for windows, doors opening etc complete all as specified and as directed
S&F in repairs fancy type chromium plated steel knobs for fixing curtain rod complete all as specified and as directed by the Engineer-in-Charge.
M&L for 20mm thick granite work (of any type) machine cut, table rubbed and polished in steps, pillars, jambs, window cills, cooking platform and the like in cement mortar 1:4 and pointing in cement mortar 1:2 using marble dust with admixture of pigment to match with the shade of granite laid over 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 25mm dia. steel tubing including all connections and fittings complete all as specified and as directed.
Taking up or down 20mm dia. steel tubing including all connections and fittings complete all as specified and as directed.
Taking up or down 15mm dia. steel tubing including all connections and fittings complete all as specified and as directed.
S&F 20mm internal dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F 25mm internal dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F 32 mm internal dia. 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 25mm globe valve (PPR with steel ball) with iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110 mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs PVC (SWR) pipes 75 mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S & F 40/50mm dia PVC pipes for WHB/Sink waste pipes fixed to walls including fiitings and connecting to multiple floor trap complete all as specified and directed.
S & F PVC (SWR) vent cowl 110mm complete all as specified and directed.
S&F PVC (SWR) multi floor trap 75mm dia. outlet with grating including jointing with solvent cement complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed by the Engineer-in-Charge.
S & F of 75mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S & F of 75mm dia PVC (SWR) bends any radius provided with access door complete all as specified and as directed.
S & F of 75mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engineer In Charge.
S & F of 110mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed by Engineer In Charge.
M&L for brickwork with fly ash bricks, straight or curved on plan n. exc. 6m mean radius, built in cement mortar 1:4 complete all as specified and directed by the Engineer-in-Charge.
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling on fair faces of concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over wall care putty of 2mm thick over one coat of primer on walls complete all as specified and as directed.
M & L for complete removal existing treatment and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment on internal walls and applying two coats of plastic emulsion over one coat of primer including 2mm thick wall care putty on walls complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of existing treatment on walls and applying two coats of weather proof exterior emulsion over one coat of primer complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm dia. fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm dia. chromium plated pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs, 15mm dia. chromium plated angle stop valves, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F health faucet 15mm dia. with 1.5 m long easy flex tube in chromium finish and wall look complete all as specified and as directed by the Engineer-in-Charge.
S&F two way bib cock 15mm dia. chromium plated, fancy type of make Jaquar Catlogue No.FON-40041 or equivalent in CERA complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs, tubular towel rail stainless steel, 20mm dia., 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S&F wash hand basin of size 550x400 vitreous China (flat back or angle back type) including half pedestal and cutting for and pinning in ends of brackets or erecting stand including supply and fixing of waste coupling, waste pipe etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs, vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, low level flushing cistern 10 ltr capacity and flush pipe and seat cover etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs, vitreous China urinals, half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC flexible connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed by the Engineer-in-Charge.
Demolition of roof projections, drops/chajja projection and other thin RCC sections of width 10-20cm and thickness 7-10cm including cutting the reinforcement edges and finishing the disturbed surfaces with ave. 5mm thick CM 1:3 and three coats of white wash on ceilings etc. complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of Asbestos sheet (corrugated/semi corrugated,etc) or fibre glass reinforced translucent corrugated sheet in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of water tank of capacity exc. 500 Litr. and n. exc. 1,000 Litr. capacity complete all as specified and directed.
S&F 700 litres capacity rotational moulded polyethylene water storage tanks three layered white colour(cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part-I and as directed.
Taking down water proofing treatment on roof slab i.e APP Membrane including cement plaster complete all as specified and directed.
M & L for brushing neat cement slurry with 3.0 Kg of cement per Square metre complete all as specified and directed.
M&L for screed bed or bedding layer of 10mm thick with CM 1:4 with water proofing compound on concrete surfaces for laying roof treatment complete all as specified and as directed by the Engineer-in-Charge. Note: Water proofing compound will be measured and paid separately.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) and on primed surface by forced application and applying one coat of solar reflective bituminious aluminium paint complete all as specified and directed.
Excavation over areas n. exc. 1.5m deep and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material (Soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in complete all as soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C1, (Using 20mm graded aggregate) as in sub base complete all as specified and directed.
M&L for chequered/designer cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with white or grey cement and pigments over 20mm thick screed bed in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) in kerb stones, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
Excavation over areas n. exc. 1.5m deep and getting out in HARD/DENSE soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC 1:1½:3 type A1 (Using 20mm graded stone aggregate) nominal mix as in cover slabs for manholes, shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railings, framework of water tanks and similar work conforming to Fe 290 Gde-E-165 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc for ornamental and intricate design complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of size 600mm dia including packing under and completely surrounding pipes with concrete after they are laid and tested; in 1:4:8 type D2 (Using 40mm graded stone aggregates) complete all as specified and as directed.
M&L for 600 mm dia reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed by the Engineer-in-Charge.
M&L for extra for forming fair finished drain or channel 120 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light ,fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets etc removing materials for taking credit and making good matching to the existing colour to the disturbed surface wall/ floors etc.complete all as specified and directed by Engineer-in-Charge.
M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 1.5 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 1.5 Sq.mm. earth wire copper insulated wire connected to common earth dolly for one LED light point controlled by one way switch on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per Sl Item No. 136 above but one ceiling fan/One Exhaust fan point controlled by one way switch.
All as per Sl Item No. 136 above but one 3 pin socket out let 5 amps switch socket on independent board .
M&L for concealed point wiring PVC insulated and unsheathed cable with 2 run of 2.5 Sq.mm. FRLSH copper conductor single core multistranded 1100 Volt grade confirming to IS 694 drawn through PVC conduit of suitable size concealed metal box and 2.5 Sq.mm. earth wire copper insulated wire connected to common earth dolly for 15 Amps switch socket complete all as specified and as directed by the Engineer-in-Charge.
M&L for concealed submain wiring with two runs of 1.5 Sq.mm. PVC insulated, unsheathed FLRSH copper conductor single core multistranded and one run of copper earth wire 1.5 Sq.mm. drawn through PVC rigid/flexible conduit incoming cable and outgoing cable proper joint with suitable size of lugs, including making good of disturbed surfaces of wall, necessary clipping or conduit work complete all as specified and as directed by the Engineer-in-Charge. Note: Copper conductor 3 runs of 1.5 Sq.mm and along with PVC rigid/flexible conduit shall be measured as one length.
M&L for concealed submain wiring with two runs of 4 Sq.mm. PVC insulated, unsheathed FLRSH copper conductor single core multistranded and one run of copper earth wire 4 Sq.mm. drawn through PVC rigid/flexible conduit incoming cable and outgoing cable proper joint with suitable size of lugs, including making good of disturbed surfaces of wall, necessary clipping or conduit work complete all as specified and as directed by the Engineer-in-Charge. Note: Copper conductor 3 runs of 4 Sq.mm and along with PVC rigid/flexible conduit shall be measured as one length.
M&L for concealed submain wiring with two runs of 6 Sq.mm. PVC insulated, unsheathed FLRSH copper conductor single core multistranded and one run of copper earth wire 6 Sq.mm. drawn through PVC rigid/flexible conduit incoming cable and outgoing cable proper joint with suitable size of lugs, including making good of disturbed surfaces of wall, necessary clipping or conduit work complete all as specified and as directed by the Engineer-in-Charge. Note: Copper conductor 3 runs of 6 Sq.mm and along with PVC rigid/flexible conduit shall be measured as one length.
S&F switch piano flush type single pole one way 5 Amps , 230V. complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination with indication lamp 2 in1 3 pin 5 Amps 240 Volts flush type multi purpose complete all as specified by Engineer- in - Charge.
S&F switch socket combination with indication lamp 2 in1 3 pin 5/15 Amps 240 Volts flush type multi purpose complete all as specified by Engineer- in - Charge.
S&F single pole and neutral sheet metal enclosures with a two pin and earth plug and socket 240 V, 50 HZ complete with one single pole MCB 20 A complete all as specified and as directed by the Engineer-In-Charge.
S&F ceiling rose surface type bakalite type, 2/3 terminals complete all as specified and as directed by the Engineer-in-Charge.
S&F stepped type electronic type single module fan step regulator 240 Volts, 120 W 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet metal enclosure MCB DB TPN double door type, AC 415 Volts, 4 way with 200 Amps rated bus bar, vertical/ohrizantal type, IP 43 protection including taking dwon old DB and making good distructed surface complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet metal enclosure MCB DB SPN double door type, AC 240 Volts, 8 way with 200 Amps rated bus bar, vertical/ohrizantal type, IP 43 protection including taking dwon old DB and making good distructed surface complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB TPN 63 Amps, C series 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB DP 40 Amps, C series 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB DP 32 Amps, C series 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB SP 6 to 40 Amps, C series 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F retrofit 20 Watt linear LED T8 tubular lamp with extruded aluminium body, PC diffuser and inbuilt driver alonge with LED batten suitable for T8 LED lamps 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No.LTT8-20 for the lamp and DMLN1LT8-16 for the batten or equivalent in Philips/C&S/ Havells/Wipro
S&F LED mirror light fitting 2 feet 14 Watts, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton LINNET model Cat. Part No.LCL-14-CDL or equivalent in Philips/C&S /Havells/Wipro
S&F in repairs, LED street light fitting 30 W, IP 65, 230 Volts, 50 Hz with compact size and robust design complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Freedom+ model Cat. Part No.LSTS-30-CDL or equivalent in Philips/C&S/Havells/Wipro
S&F LED bulk head fitting, 10 W, 230 Volts, IP 65, 50 Hz with suitable for indoor and outdoor application complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Sunrise model Cat. Part No.LBH-10-CDL or equivalent in Philips/C&S/ Havells/Wipro
S&F LED bollard lights 10 W, 230 V, 50 Hz efficient high output LED with IP 66 protection and pressure die-cast powder coated housing with all accessories complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton MAYA I Cat. Part No.LBLA1-10-CDL or equivalent in Philips/C&S/ Havells/Wipro
S&F in repairs, house service bracket 1.5 mtrs. long GI pipe 40mm dia. medium grade two Nos. 90 degrees bends MS hook and stay or guy complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screen PVC bedded galvanised steel strip wire armoured electrical power cable 1100 V grade with stranded aluminium conductor of size 35 sqmm 3.5 core including cable gland complete all as specified and directed by Engineer-in-charge.
Supply and lay cable XLPE insulated screen PVC bedded galvanised steel strip wire armoured electrical power cable 1100 V grade with stranded aluminium conductor of size 6 sqmm 2 core including cable gland complete all as specified and directed by Engineer-in-charge.
Supply and lay common burnt clay building bricks sub-class 'B', of sze 230x113x75 for cable protection complete all as specified and as directed by Engineer-in-Charge.
Supply and lay 40mm dia, galvanised steel tubing, light grade for cable protection including removal of existing GI pipe complete all as specified and directed by Engineer-in-Charge.
Supply and spread clean river sand in cable trenches and providing cushioning for the cable complete all as specified and directed by Engineer-in-Charge. Note: Only punned thickness of 18cm will be measured for the purpose of payment.
Taking down and refixing after repairs ceiling fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed by the Engineer-in-charge.
Taking down and refixing after repairs Exhaust fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed by the Engineer-in-charge. Note for Item No.166 & 167 : Bearing/gun metal bush/rubber bush & bolts/ capacitor/rewinding/cord flexible/shaft etc. will be measured and paid separately.
Supply only cord flexible copper conductor three core 23/0.0076 Sqmm PVC insulated sheathed 1100 V grade complete all as specified and as directed by the Engineer-in-Charge. Make: Finolex/Nicco/Havells/HPL India. Ltd.
Supply only oil capacitor of 2.5 Mfd suitable for ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
Supply only oil capacitor of 4 Mfd suitable for ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
Supply only ball bearings, bearing No.6201 suitable for ceiling fan/wall mounted/exhaust fan/air circulator of any sweep any make/model complete all as specified and as directed by the Engineer-in-Charge. Make: NBC/ TATA/ SKF
All as per Sl Item No. 171 above but bearing No.6202
All as per Sl Item No. 171 above but bearing No.6203
Supply only MS down rod 15mm bore and 450mm long including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Supply only rubber bush with bolt and nut suitable for ceiling fan of any make/model/sweep complete all as specified and as directed by the Engineer-in-Charge.
M&L for rewinding of ceiling fan of 1200/1400mm sweep of any make/model, including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete all as specified and as directed by the Engineer-in-Charge.
All as per Sl Item No. 176 above but Exhaust fan from 300 mm to 450 mm sweep.
M&L for cleaning/preparation of surfaces of ceiling fan 1200mm sweep thoroughly and painting with one coat of spray painting using synthetic enamel white paint over the existing paint and stenciling of MES No. with black paint over it complete all as specified and as directed by the Engineer-in-Charge.
All as per Sl Item No. 178 above but Exhaust fan from 300 mm to 450 mm sweep.
M&L for earthing complete with 7.5m CI pipe 80mm dia. with flanged ends, centifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slote up to 7.5m length buried directly and preferably vertically in ground with top flanged ended 7m below ground level welded/ connected with GI strip 32x6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcol common salt surrounding the earth pipe includingdrilling 400mm dia. bore in any strata of soil to lower the CI pipe complete all as specified and as directed by the Engineer-in-Charge. Note: The rate quoted is deemed to be included the earth pit chamber, CI cover and earth lead 32x6mm GI strip from earth pit to DB upto 7 mtrs. length and testing on completion.
P SRINIVASA RAO
N V S S K N SIVA PRASAD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .