Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹18.1 L+₹16,145 (0.90%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹19.4 L+₹1.5 L (8.21%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹22.0 L+₹4.1 L (22.6%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹26.5 L+₹8.5 L (47.6%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Nov 2021, 6:00 pmClosed
GE Dehu Road, Pune
GE Dehu Road, Pune
REWIRING AND REPAIR TO FITTING FIXTURE OF MD AND OTM ACCN UNDER GE DEHU ROAD
2021_MES_479630_1
8564
Open Tender
Civil Works
Item Rate
270 days
GE Dehu Road, Pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dehu Road, Pune
₹80,000
Yes
31 Dec 2021
5 Oct 2021
9 Nov 2021
5 Oct 2021
3 Nov 2021
20 Oct 2021
Amount
Taking down copper / aluminium point wiring (Light, fan, socket or power socket) complete including fixtures and fittings such as switches , ceiling roses, pendants, holders, regulators, socket, light fitting etc and making good disturbed surfaces of walls, floor etc. complete all as directed.
Taking down unserviceable Main switch, MCB DB including MCBs etc. and making good disturbed surfaces of walls complete all as directed.
M&L for Point wiring complete with and including 1.5 sq. mm ( nominal area) single core multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade FRLSH, I S I marked drawn through and including PVC casing caping suitable size with accessories such as bend ,tees, junction boxes etc. incl. 1.5 Sqmm PVC insulated and unsheathed multi stranded copper conductor as earth wire including PVC premoulded switch board ISI marked suitable size for housing switch, socket and fan regulators etc complete and making good the disturbed surfaces of wall by cement patch all and matching the surface to the existing finising colour all as specified and directed for the following :-
One light point controlled by one one way switch.
One Fan point controlled by one one way switch.
One light point controlled by two 2 way switches.
One bell point controlled by one bell switch.
One 5 pin 5 Amps socket outlet on the same board with other switch controlled.
One 5 pin 6 Amp switch socket outlet on the independent board.
Ditto all as per item No 3 above but wiring with 2.5 sq. mm multy stranded copper conductor PVC insulated but unsheathed FRLS cable for 5 pin 15 Amps multi purpose socket outlet.including 2.5 Sqmm PVC insulated and unsheathed single core copper conductor cable as a earth wire to common earth connection to earth duly completed all as specified and as directed by Engr-in-Charge.
M&L for concealed point wiring for light/call bell/fan/exhaust fan point with cables 1.5 Sqmm PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade FRLSH, confirming to IS - 694 drawn into and including PVC concealed conduit with pressed steel terminal boxes of adequate size with 3 mm thick plastic laminated sheet , cover of adequate size for light/fan/Exhaust fan/ call bell controlled by one switch incl 1.5 Sqmm copper conductor cable multistrand PVC insulated and unsheathed as earth wire to common earth duly complete all as specified. Note- Item rate includes cutting chases in wall/floor/ceiling and making good surface.
One light point controlled by one one way switch.
One Fan point controlled by one one way switch.
One light point controlled by two 2 way switches.
One bell point controlled by one bell switch.
One 5 pin 5 Amps socket outlet on the same board with other switch controlled.
One 5 pin 6 Amp switch socket outlet on the independent board.
Ditto all as per item No 5 above but wiring with 2.5 sq. mm multy stranded copper conductor PVC insulated but unsheathed FRLS cable for 5 pin 15 Amps multi purpose socket outlet.including 2.5 Sqmm PVC insulated and unsheathed single core copper conductor cable as a earth wire to common earth connection to earth duly.
S&F swith piano flush type ,single pole one way 5 Amp.
S&F swith piano flush type ,single pole Two way 5 Amp.
S&F Bell push, flush type, 5 amp all as specified.Make Anchor cat no 14113 or equivalent in HPL/Leader
S&F ding dong electric calling bell 240V, 50Hz, AC complete all as specified.
S&F socket outlet 2-in-1, 3 pin 5 Amps.
S&F switch socket combination 2-in-1, 5 Amps flush type.
S&F socket outlet 2-in-1, 5 pin 15 Amps Flush type.
S&F in repair Switch 15 Amps Flush type.
S&F ceiling rose surface type ISI marked 65 x 50 mm three terminals type.
S&F White Angle lamp holder, ISI marked with metal ring Insulated body with back plate for batten fitting complete.Make Anchor Cat no 39797
S&F step type electronic regulator of ceiling fan capacitor based ISI marked 230 v 100 watt.Make Anchor Cat no 8410
S&F in repair following :-
Modular switch 1 way 6A , 230 V, 1 Module single pole.
Modular switch 2 way 6A , 230 V, 1 Module single pole.
Modular switch 1 way 16 A, 230 V, 1 Module single pole.
Modular calling bell switch 6 A, 230 V, 1 Module.
Modular socket outlet 2/3 pin , 6 Amps, 2 module.
Modular switch socket combination 2 in 1, 5 Amps Flush type.
Modular socket outlet 5/6 pin , 6/16 Amps, 2 module.
Modular fan regulator , 120 W , 2 Module.
Modular white cover plate with frame 1 module.
Modular white cover plate with frame 3 module.
Modular white cover plate with frame 6 module.
Modular white cover plate with frame 8 module.
S&F in repair of PVC board of size 10X8 cm with arrangement to accommodate switch/socket/regulator complete all as specified.
S&F in repair of PVC board of size 7X4 cm with arrangement to accommodate switch/socket/regulator complete all as specified.
S&F in repair of PVC board of size 4X4 cm with arrangement to accommodate switch/socket/regulator complete all as specified.
S&F in repair of PVC Block of size 75 mm for fluroscent fittings in shape of round/ Square complete all as specified.
S&F MCB SP 6 to 40 Amps 240 volts 50 Hz having 'B' Curve complete all as specified and as directed.
S&F MCB SPN 6 to 40 Amps 240 volts 50 Hz having 'B' Curve complete all as specified and as directed.
S&F MCB SPN 63 amps, AC, 240V, 50 Hz,having 'B' Curve complete all as specified and as directed.
S&F MCB TPN 63 Amps 415 volts having 'B' Curve complete all as specified and as directed.
S&F MCB TPN 100 Amps 415 volts having 'B' Curve complete all as specified and as directed.
S&F MCB 4 pole 63 Amps 415 volts having 'B' Curve complete all as specified and as directed.
S&F MCB 4 pole 100 Amps 415 volts having 'B' Curve complete all as specified and as directed.
S&F sheet metal enclosures double door distribution board IP 20- Ik- 08 factory made duly painted 12 way SPN and neutral 240 v with 200 amps fully insulated rated copper bus bar.
S&F sheet metal enclosures double door distribution board IP 20- Ik- 08 factory made duly painted 8 way SPN and neutral 240 v with 200 amps fully insulated rated copper bus bar.
S&F distribution board sheet metal enclosures for single door factory made duly painted 4 way SPN 240 V , suitable for fixing MCB /Isolators all as specified .
S&F vertical distribution board in sheet metal enclosure with double door factory made 4 way TPN,415 Volt IP- 54 IK-09 suitable for fixing MCCB TP as main incoming duly painted all as specified with insulated copper bus bar 200 amps insulated neutral bar and cable ties for cable management, corner shield for better protection , masking sheet and pan assembly for easy installation
Fixing only 4 feet 18W linear aluminium LED Batten professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size. Note: LED batten will be issued free for fixing under Schedule 'B'.
Fixing only of 4 feet 20W linear aluminium LED Batten professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size. Note: LED batten will be issued free for fixing under Schedule 'B'.
Fixing only 4 feet 22W linear aluminium LED Batten professional CW 6500K cool white complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size complete with acessories. Note: LED batten will be issued free for fixing under Schedule 'B'.
Fixing only 2 feet 10 W linear aluminium LED Batten with white acrylic cover complete with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size. Note: LED batten will be issued free for fixing under Schedule 'B' .
Fixing only 7 Watt LED light high power low heating superflux LEDs, 100 lumen/ watt, 120-270 V AC inbuilt electronic driver, with all accessories prewired and connecting up twin core twisted flexible copper conductor cable with suitable size complete all as specified. Note: LED light will be issued free for fixing under Schedule 'B'.
S&F 10W Surface mounted downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency all as specified & directed. Make :Philips, Bajaj, Havells and HPL.
S&F 12 W Star Slim LED Panel light with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency all as specified & directed. Make- Philips, Bajaj, Havells and HPL.
S&F 28 W Recess Mounting Pluto Neo Panel 2x2 down light environment friendly, new generation aesthetically designed, ultra modern with high brightness SMD LEDS as light source, suitable for armtrong/Grid ceiling all as specified & directed. Make :Philips, Bajaj, Havells and HPL.
Taking down carefully old u/s submain wiring of any type and making good the disturbed surface of walls /floor complete all as directed.
M&L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 4.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 4.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawan into and including PVC casing caping with accessories of suitable size as required and all as directed by engr-in-charge. Note:- Two run of main wire and one run of earth wire including casing caping shall be measured as one length.
M&L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 4.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 4.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawn into and including PVC concealed conduit with accessories of suitable size including necessary cutting chases as required and all as directed by engr-in-charge. Note:- Two run of main wire and one run of earth wire including conduit shall be measured as one length.
M&L for sub main wiring with two runs of single core PVC insulated multistranded unsheated FRLS cable 6.0 sqmm (nominal area) 1100 Volts grade copper conductor with one run of 6.0 sqmm PVC insulated unsheated single core copper conductor multistrand 1100 volt grade as a earth wire drawan into and including PVC casing caping with accessories of suitable size as required and all as directed by engr-in-charge. Note:- Two run of main wire and one run of earth wire including casing caping shall be measured as one length.
M&L for Earthing complete with Galvanised steel earth plate electrode 60 cmx 60 cm x 6.3 mm thick buried bellow ground level connected to galvanised earth lead directely in ground earth pit not less than 2.75 mtr deep wire 4.0 mm dia by means of bolts , nuts, check nuts, and washer of galvanised iron or steel all as shown in electrical plate No-3 SSR Part-1 of 2009 connecting to earthing test point all as specified and directed ,including necessary excavation and earth work in any type of strata ,concrete pit, CI frame and cover with locking arrangement all as specified and directed by Engr-in-charge.
Taking down U/S ceiling fan of 1200mm sweep of any make and dismantling/open fan and taking burnt out winding after cutting and cleaning the slots and rewinding the same with super enamelled copper wiring with suitable gauge not less than 1.2 kg per fan including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing complete and re-fixing in same position all as specified and directed by Engr-in-charge.
All as per item no 47 above but 1400 mm sweep super enamelled copper winding wire suitable guage not less 1.4 Kg per fan.
Taking down U/S exhaust fan 275 to 300 mm sweep of any make and dismantling/open fan and taking burnt out winding after cutting and cleaning the slots and rewinding the same with super enamelled copper wiring with suitable gauge not less than 400 gm per fan including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing complete and re-fixing in same position all as specified and directed by Engr-in-charge.
Taking down U/S exhaust fan 350 to 450 mm sweep of any make and dismantling/open fan and taking burnt out winding after cutting and cleaning the slots and rewinding the same with super enamelled copper wiring with suitable gauge not less than 400 gm per fan including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing complete and re-fixing in same position all as specified and directed by Engr-in-charge.
Taking down U/S wall mounted fan 400 mm sweep of any make and dismantling/open fan and taking burnt out winding after cutting and cleaning the slots and rewinding the same with super enamelled copper wiring with suitable gauge not less than 400 gm per fan including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing complete and re-fixing in same position all as specified and directed by Engr-in-charge.
S&F in repair Ball bearing to match the existing size of ceiling fan sweep 1200/1400mm including greasing all as specified.
S&F in replacement of canopy for ceiling fan 1200/1400mm sizes and all as specified and as directed by Engr-in-Charge.
M&L in repair Fan capacitor 2.5 mfd for ceiling fan 1200 mm all as specified.
M&L in repair Fan capacitor 4 mfd for exhaust fan all as specified and as directed by Engr-in-Charge.
M&L for spray painting of ceiling fan of any make/sweep with white synthetic enameled paint after preparation of old surface by cleaning with soap/detergent and drying of white synthetic enameled paint including writing of MES No. with black synthetic enameled paint with existing pattern all as directed by Engr- in- charge
M&L for spray painting of Exhaust fan of any make/sweep with white synthetic enameled paint after preparation of old surface by cleaning with soap/detergent and drying of white synthetic enameled paint including writing of MES No. with black synthetic enameled paint with existing pattern all as directed by Engr- in- charge
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
M & L Air termination, single pointed aluminium rod 12mm dia and 300mm long
M & L Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M/S kirpan Enterprises
PREETI ENTERPRISES
metro electrical services
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .