Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
4 May 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SRDSTE/RJT
16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of tender. NOTE: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange,incorporated/registered atleast 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above workexperience certificate.
Definition of Similar Nature: - "Any signaling work involving outdoor work and/or addition and/or alteration in existing indoor signaling system. OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving Indoor and /or Outdoor. Similar work to include indoor if the tendered work involves addition and/or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work OR Any such work involving activities as given in the name of tendered work."
Alteration is required in Existing Westrace make Electronic Interlocking System and Existing VDU layout of KHDI station. therefore "The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extant RDSO guidelines and to meet contract specific requirements."
Undertaking by the tenderer that the equipment of EI shall be procured from RDSO approved sources and modification, alteration, installation and testing of EI shall also be got done from the same source/OEM including after sales support required during warranty period should be submitted. ( Click here to download Format)
18 conditions · 3 needing a document upload
1.EMD/Bid security is deposited as per Clause 5 of Part I "regulations for tenders and contract " of tender document. 2. EMD need to be deposited online on www.ireps.gov.in. 3. For the tenders costing upto 50 Lakhs: - No technical and financial credentials required but firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding. 4. tender having value more than 50 Lakhs: - Financial and technical credentials required as per GCC applicable and firm's documents and any other mandatory documents which are demanded in tender are require to be submit at the time of bidding.
1. If Tenderer is sole proprietor: Affidavit on Stamp paper of appropriate value declaring that his/her concern is a Proprietary concern or any other documents such as GST Certificate, PAN Card of firm Name etc. is to be submitted. 2. If Tenderer is partnership firm: Notarized partner ship deed Original/Notarized power of attorney. 3. If Tenderer is JV/Limited Company: Copy of Memorandum and Articles of Association of the company. Power of Attorney (duly registered/notarized as per prevailing law) by the company authorizing the person to do/act on behalf of the company. 4. If Tenderer is Company: Copies of MOA (Memorandum of Association) & AOA (Articles of Association) of the company. Power of attorney duly registered/notarized by the company in favour of the individual signing the tender on behalf of the company. Resolution of Board of directors in regards of approving Power of attorney issued. 5. If Tenderer is Society: Attested copy of the certificate of registration. Deed of formation. Power of attorney in favour of the tender signatory. 6.Copy of PAN number and TIN number.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rajkot division-S&T Work in connection with (i) Providing ROB in lieu of LC No 135 at Km 755/0-1 Between KHDI - PDH section(2 lanes) (ii) Providing ROB in lieu of LC No 147 at Km 770/1-2 Between PDH - CX section(2 lanes) (iii) Proposed LHS in lieu of LC No. 92 at Km 698/1-2 bet LXR-WKR (iv) Kanalus: Rectification of bad layout from Pt 112 towards PBR side by shifting the turnout by 18m towards RJT.
DRM-RJT-26-27-SnT-E-2
DRM-RJT-26-27-SnT-E-2
Open
Works - General
12 Months
Rajkot, Gujarat
₹0
₹2.8 L
4 May 2026
10 Apr 2026
20 Apr 2026
716 items across 14 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 22,00,800.85 | ||
| — | 1.00 | — | — | ||
| Electrically Operated Lifting Barrier complete set suitable for 24V DC supply with out hand generator & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting 02 Nos of Barriers of length 09.76 Mtrs. alnog with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2. (Should be Individual operation of both boom) | — | — | — | 4,88,523.3 | |
| — | 1.00 | — | — | ||
| LED type control-cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate , depicting the yard layout Signal, Point, Track circuit, Operating / emergency Push Button, counter with sealing arrangements, house in a Steel metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 ver. 1 or latest amendment | — | — | — | 66,080.63 | |
| — | 1.00 | — | — | ||
| Cost of supply & fixing of yellow retro-reflective sheet on lifting barrier boom. Intenisity grade,encapsulated grade prismatic grade Size 305x290mm one set consist 18 pieces | — | — | — | 1,918.6 | |
| — | 1.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 30,815.59 | |
| — | 4.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area THREE Aspects complete (without lanse, lamp, holder, transformer) suitable for LED signal as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. NoRDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Supply of LED Unit is not covered in this item). | — | — | — | 1,27,207.36 | |
| — | 4.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area TWO Aspects complete (without lanse, lamp, holder, transformer) suitable for LED signal as per RDSO DRG. No. SA 23No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Supply of LED Unit is not covered in this item) | — | — | — | 1,21,424.44 | |
| — | 9.00 | — | — | ||
| "Colour Light Signal Complete. This includes: - (1). Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3). Pinnacle. (4). Ladder Assembly, as per RDSO Drg. No. SA- 23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5m / 4.5m/ 3.5m Long. Quantity of each will be decided by the engineer in charge." | — | — | — | 1,09,450.62 | |
| — | 10.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring . 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. | — | — | — | 18,678.5 | |
| — | 6.00 | — | — | ||
| Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 or latest ; 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 3,862.74 | |
| — | 250.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 19,255 | |
| — | 150.00 | — | — | ||
| "Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments.Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)" | — | — | — | 9,268.5 | |
| — | 15.00 | — | — | ||
| Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement. | — | — | — | 172.5 | |
| — | 15.00 | — | — | ||
| Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement. | — | — | — | 172.5 | |
| — | 3.00 | — | — | ||
| Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 362.64 | |
| — | 1.00 | — | — | ||
| Markers strip for above item (i) | — | — | — | 17.63 | |
| — | 3.00 | — | — | ||
| Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. | — | — | — | 15,755.88 | |
| — | 3.00 | — | — | ||
| Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. | — | — | — | 7,548.87 | |
| — | 100.00 | — | — | ||
| Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. This also includes supply of equivalent no of ND type Fuses of 20A capacity as per specification IRS S-78/92. | — | — | — | 14,565 | |
| — | 100.00 | — | — | ||
| Round head type non detoriating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 6A/10A capacity. | — | — | — | 6,321 | |
| — | 50.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 2,858.5 | |
| — | 50.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 1,043.5 | |
| — | 200.00 | — | — | ||
| ND Fuse Cylindrical Type 16 Amp IRS:S. 78/92 | — | — | — | 10,856 | |
| — | 200.00 | — | — | ||
| ND Fuse Cylindrical Type 20 Amp IRS:S.78/92 | — | — | — | 11,328 | |
| — | 1.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 25,617.82 | |
| — | 1.00 | — | — | ||
| Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)" | — | — | — | 27,887.12 | |
| — | 3.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3). | — | — | — | 17,749.26 | |
| — | 1.00 | — | — | ||
| "Ferro resonant type automatic AC voltage regulator 3 KVA capacity input 160-270V, output 230V as per RDSO Specn IRS S:74/89 with amendment-6 or latest. Accepted Make - ESTAR. " | — | — | — | 41,554.88 | |
| — | 30.00 | — | — | ||
| Rubber Mat for Power Equipment room. ( 5mm thick-RE fit) | — | — | — | 3,427.8 | |
| — | 6.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/ 2002, BRS: 941A, IRS:S34 and IRS:S23 (as applicable) | — | — | — | 33,830.28 | |
| — | 8.00 | — | — | ||
| Relay, AC Immune, Plug-in-type, style "QNA1K" ACI DC Netural line, 24V DC 1000 Ohms 6F.6B contacts, front contacts metal to carbon and back contacts metal to cabon. complete with plugboard, retaining clip and connectors confirming to IRS:S34, IRS:S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA(PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY. | — | — | — | 44,946.32 | |
| — | 2.00 | — | — | ||
| Fail safe electronic time delay device mounted on Q series relay base & covered with fixed timing of 60/120/180/240 seconds as specified by purchaser conforming to IRS.S. 61-2000 or latest. | — | — | — | 14,100.78 | |
| — | 3.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC Immunized with different ward combinations (Three ward plates to be supplied with each relay). | — | — | — | 25,633.32 | |
| — | 2.00 | — | — | ||
| Fail safe electronic flasher device 24 DC/110V AC as per RDSO Spec No. RDSO/SPN/173/2002 (Amd.2) or latest. | — | — | — | 17,866.88 | |
| — | 3.00 | — | — | ||
| Dual tone bell/buzzer with 25W horn, working on 24 V DC for road user. | — | — | — | 27,876.27 | |
| — | 2.00 | — | — | ||
| Road warning flasher kit for L.C. gate as per circuit design. | — | — | — | 3,915.44 | |
| — | 4.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/ 2008. | — | — | — | 35,401.88 | |
| — | 0.20 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89. | — | — | — | 8,752.41 | |
| — | 0.20 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/ Km and test parameters as per IRS(S) 76/89. | — | — | — | 28,070.89 | |
| — | 1.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | — | — | 14,765.08 | ||
| — | 8.00 | — | — | ||
| — | — | — | 30,175.04 | ||
| — | 1.00 | — | — | ||
| — | — | — | 21,150 | ||
| — | 10.00 | — | — | ||
| — | — | — | 2,904.1 | ||
| — | 2.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | — | — | 22,414.1 | ||
| — | 1.00 | — | — | ||
| — | — | — | 5,243.92 | ||
| — | 1.00 | — | — | ||
| Megger 100V to 500V X 20 mega ohms as per specification make: Fluke model No 1507,Motawani or similar. | — | — | — | 39,332.94 | |
| — | 1.00 | — | — | ||
| Mini AC/DC Low Current Clamp Meter as per Specn. High Sensitivity, Miniature type Clamp, Resolution of 0.1 mA for AC,1 mA for DC Current, Measurement range 0-20 A MakeKEW, Fluke or similar. | — | — | — | 39,819 | |
| — | 3.00 | — | — | ||
| SS AC Box HALF(Fabricated of 2.5mm SS Sheet, Fixed Type) | — | — | — | 1,90,260 | |
| — | 2.00 | — | — | ||
| SS AC Box FULL(Fabricated of 2.5mm SS Sheet, Fixed Type) | — | — | — | 1,46,008 | |
| — | 1.00 | — | — | ||
| MS Sliding type mechanical Boom barrier assembly 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per Drg. | — | — | — | 1,32,154.25 | |
| — | — | — | 19,84,863.82 | ||
| — | 1.00 | — | — | ||
| Electrically Operated Lifting Barrier complete set suitable for 24V DC supply with out hand generator & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with latest amendment. One set consisting 02 Nos of Barriers of length 09.76 Mtrs. alnog with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2. (Should be Individual operation of both boom) | — | — | — | 4,88,523.3 | |
| — | 1.00 | — | — | ||
| LED type control-cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate , depicting the yard layout Signal, Point, Track circuit, Operating / emergency Push Button, counter with sealing arrangements, house in a Steel metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 ver. 1 or latest amendment | — | — | — | 66,080.63 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DRM-RJT-26-27-SnT-E-02-GCC2022ACS11.pdf
ATTACHMENT
ACSUPTO11_compressed.pdf
ATTACHMENT
Special condition of contract
ATTACHMENT
26-27-E-2SpecialconditionofContractfor4combinedwork.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .