| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.1 L+₹3.4 L (18.1%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹23.5 L+₹4.8 L (25.6%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹24.7 L+₹6.0 L (31.8%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹26.3 L+₹7.5 L (40.2%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
18 Mar 2021, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF AC PLANT AT SAMUDRIKA AND CERTAIN MISECELLANEUOUS REPAIRS AT SATVAHAN AND NAVAL DOCKYARD AREA UNDER AGE E/M-I OF GE(U-I) VISAKHAPATNAM
2021_MES_423900_1
8303/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility-I
₹65,000
Yes
12 May 2021
20 Feb 2021
19 Mar 2021
20 Feb 2021
18 Mar 2021
5 Mar 2021
Amount
Supply and replace MCCB 4 pole, 415 V, adjustable type 630 Amps with breaking capacity 50 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 400 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 315 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 250 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 200 Amps with breaking capacity 35 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 160 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
Supply and replace MCCB 4 pole, 415 V, adjustable type 100 Amps with breaking capacity 25 KA including necessary modification in the panel complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 630 to 1000 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :-
a) Cleaning the insulation parts including bushings with CTC solution.
b) Checking the alignment and condition of movable and fixed contacts and adjust them all as per manufacturer's instructional manual
c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the wornout parts.
d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear.
f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required.
g) Replacing the badly worn or burned contacts. Checking control device free for operation.
h) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional
Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc
Supply and install ON LOAD change over switch 415V 4 pole of capacity 630 Amps in open execution type fixing in existing panel if required then including necessary modification in the panel and including dismanlting old one. Make : L&T/ Havells/ HPL/GE/Indo Asian
Supply and install ON LOAD change over switch 415V 4 pole of capacity 400 Amps in open execution type fixing in existing panel if required then including necessary modification in the panel and incl dismanlting old one. Make : L&T/ Havells/ HPL/GE/Indo Asian
Supply and fixing and testing of the following Spare Parts as required during repair of 4x48 TR ciller acF AC plant of Bluestar, complete all as directed
For Chiller unit no -1 (XAC2YS-048AR2)
Supply of main MCCB
Supply of cable legs
M&L for full jet whash service along with chemical wash service
For Chiller unit no -2 (XAC2YS-048AR2)
M&L for rectification of gas leak in circuit 1 ,nitrogen testing and commissioning charges along with necessary charges
Material and labour for R407C refrigerant
S&F of filter driers
M&L for full jet wash service along with chemical wash service
For Chiller unit no -3 (XAC2YS-048AR2)
Supply and fixing of contactor(CHNT40A)
S&F of EWT/LWT sensor
M&L for full jet wash service along with chemical wash service
For Chiller unit no -4 (XAC2YS-048AR2)
M&L for rectification of gas leak in circuit 1 ,nitrogen testing and commissioning charges along with necessary charges
Material and labour for R407C refrigerant
S&F of filter driers
M&L for full jet wash service along with chemical wash service
M&L for full jet wash service along with chemical wash service for AHUs
M&L for maintenance/servicing of PT unit 11Kv / 110V by disconnecting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of bus bar connections, resin cast PTs using hot blower, CTC solution, applying backlot (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Taking down HT switch gear (Vacuum circuit breaker ) of capacity 11 KV 250/350 MVA comprising of following repairs, overhauling, servicing, carrying out preventive maintenance and refixing the same after repairs/ overhauling:
(a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling
(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required.
(b) Servicing/Inspecting/checking of circuit spout and circuit spout connections for RYB phases and replacement of spares if required.
(c) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc.
(d) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism.
(e) Servicing/Inspecting/checking of secondary sockets/bus bar earthing plugs/earthing sockets and replacement of spares if required.
(f) Checking, setting and adjustment of lowering and raising operation of the breaker trolley.
(g) Decarbonising of bus bar and connected items
(h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly.
(J) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components
Notes: (i)The servicing includes for bus bar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc. will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement. (iv) the servicing shall be carried out by Authorised service centre as approved by GE
M&L for rectification of faults and retrofit of electrical circuit of 11 KV VCB with suitable IED's by checking CT/PT healthiness , proper programming of multifunctional meters and replacement of defective components & wiring with FRLSH multistrand PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed Note :- Required new components will be measured and paid separately under relevant items.
VCB Control circuit comprising of the following:-
i) Numerical feeder protection relay - 1 No.
ii) Trip circuit supervision relay - 1 Nos
iii) DC supply supervision relay - 1 No.
iv) High speed tripping relay - 1 No.
v) Auxiliary relay- 1 Set
vi) Multifunction meter, Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1 - 1 No.
vii)Digital Voltmeter , Ammeter - 1 Set
viii)Indication Lamps & Annunciator - 1 Set
ix) Control Switches & Wiring with appropriate colour coding , complete which are required for smooth / satisfactory operation of CRP as per scheme requirement
x) T‐N‐C Switch (Breaker Control Switch) - 1 Set
xi) Circuit label - 1 No.
Supply , install ,Testing , Commissioming of Numerical feeder protection relay 50/51N (Earth over current),67P (3Ph directional over current),67N (Earth fault directional over current), 51V (Voltage controlled over current), 37 (3Ph under current),46 (Negative Phase sequence over current),59N (Residual over voltage),32 (Directional power protection under/over active/Reactive power),81 (Under over over Frequency ), 49 (Thermal Overload),79 (Auto resue),50BF (Circuit breaker failure direction),Cold pickup,Inrush blocking including taking down old relay complete all as specified and directed by Engr-in Charge.Relay will be on Modbus Protocol.(Make:- Schneider of Model Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 or its equivalent in ABB/SEIMENS)
Supply and fixing High Speed Master Trip Relay
Supply and fixing the following for Metering :
Supply and fixing the INDICATION LAMPS for C.B. ON/OFF/TRIP/Trip Circuit Healthy and Unhealthy/Spring Charged
Supply and fixing the following for Control switches & Control Wiring
T‐N‐C Switch (Breaker Control Switch)
Trip Circuit Healthy Push Button
Control wiring with appropriate colours
Local Remote switch
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and directed. Make- Schneider, Part No- ECO39SN134900FN
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one all as specified and directed. Make- Schneider, Part No- ECO39SN134100FN
Supply and fix incl dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 2500 Amps all as specified and directed. Make-Schneider only. Part No-VSLVG4002-01
Supply and fix including dismantling taking out unserviceable Breaker Nylon Wheel, For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MVIA00054-01
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MVIJOO157-02
Supply and fix including dismantling taking out unserviceable Release Lever (Nylon ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only , Part No- MVIJ00010-01
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIJ000980-1
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- ERC-A-A00DC-001
M&L for replacement of damaged space heater, 230V AC supply , 100 watt inside 11 KV HT VCB cable chamber including necessary connection, testing complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- EHF-A-EV 000-001
Supply and fix including dismantling taking out unserviceable Control Circuit HRC Fuse : 2 A , 4 A , 6 A , 1 0A complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Service/Test Position Limit Switch 1NO+1NC For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- ESW-B-AAA00-001
S&F multifunctional meter with LED display, accuracy class-1, e- navigator, including dismantling taking down unserviceable one and connection, programming, testing complete all as specified and directed. Make- Elmeasure , L&T , Schneider
Supply and fix including dismantling taking out unserviceable Isolating Contact For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- MVIK00190-01
Supply and fix single (Red-Blue) phase bus bar spout suitable for 800 Amps to 1250 Amps VCB . Make Schneider Model No MEP-39- 32185 complete all as specified and directed.
Supply and fix single (Y) phase bus bar suitable spout for 800 Amps to 1250 Amps VCB . Make Schneider Model No MEP-39-32186 complete all as specified and directed.
Supply and fix Drive Beam suitable for 11 KV VCB 800 to 2000 Amps. Make Schneider Model No MCS27S0298700PN complete all as specified and directed.
Supply and fix Epoxy Body suitable for 11 KV VCB up to 1250 Amps. Make Schneider Model No MEP3953022000FN complete all as specified and directed.
Supply and fix Dive Rod assembly with contact block VG2 suitable for 11 KV VCB up to 1250 Amps. Make Schneider complete all as specified and directed.
Supply and fix CT Spout suitable for VCB 800 to 2500 Amps 25 Ka chamber insulating bus support epoxy insulator of dia 95mm and 125mm length complete all as specified and directed. Make Schneider
Supply only Resin Cast CT dual core, CT ratio- 100/50/5A-5A For 800A , 11 KV VCB panel.
M & L for de-scaling the shells and tube condenser by circulating the diluted hydrochloric acid at the appropriate ratio depend upon the scale deposits till removal of all the scale inside the copper tubes and removal of the both end covers, brushing with nylon brush, removal of all scale and degreasing with caustic soda, flushing out thoroughly, re-fixing the end covers with new gasket packing, nut and bolts and connecting the inlet and out let water connection checking of water leaks, all specified and directed.
40 TR, Model 5H4U of Voltas Make at 53M Bldg
140 TR, Model of Carrier Make at MWC Bldg
100 TR Model:Chiller unit : EROX1052P-1M/ Cond unit : 09126 of Voltas Make at 551&552 Bldg
Servicing to reciprocating type Screw water cooled liquid Compressor by strip opening of both end covers, cylinder head, cylinders connecting rod crank shaft, oil pump, side covers of bush bearing/ bush bearings etc complete. Inspecting the parts for serviceability and replacement unserviceable worn out parts in the compressor, sanction/Discharge valve needs spring, pins gasket, filters, star washers piston rings etc. cleaning the System with Nitrogen gas for leak detection after flushing out the system vacuumization and charging only refrigerant gas, replacement of compressor oil and testing the unit on no load and full load condition all as directed by Engg-in-Charge. Note: Gas, compressor oil shall be measured and paid separately under relevant schedule items.
100 TR, Model:Chiller unit : EROX1052P-1M/ Cond unit : 09126 of Voltas Make at 551&552 Bldg
M&L for taking down 48 TR Chiller package unit Direct expansion type Outdoor including dismantling the units carefully, chemical cleaning of compressor, condenser tube and control piping, with appropriate cleaning agents, flushing through proper air flow across the coils to improve the cooling efficiency, reassembling & re-installing the units in their original position including replacing defective spare parts and testing & commissioning complete all as directed by Engr-in-Charge. Note : Other than spare parts under item No 5 of Sch A shall be included in the quoted rate complete.
Supply only the following Spare Parts as required during repair of AC plant of capacity 48 TR, Model XACYS2048AR2 of Bluestar, complete all as directed
Pressure pump for 48 TR AIR cooled Chiller Unit
Comp-Scroll-SZ 185-4RM (CMSCB154L3201)
Crank Case heater SM - 185 -75W (HTFL-BL 100005-00)
Filter Drier-UDK 417S (RCDR-078F001-00)
Exp Valve TDBX19 (RCTXV-TDEBX 19-00)
Pressure Control YK -01L 400-035G050G (RCPR-LCB-00)
HI PR Switch (SAGINO) 450 AUT (SPEC-T011-00)
36 IN FAN BIRD WING 5 BLADE (BFAX - ALF003-00)
ODU FAN MOTOR-2 HP-860 RPMHIND MOTOR MOAC-02002-03)
Complete servicing of FRP cooling tower, removal of complete scales, dirt etc. by using chemicals, cleaning the sump louvers, PVC fills, fan assembly, renewal of spray nozzles, renewal of nuts and bolts, and complete painting of the cooling tower as per the standard practice for 3 x 40 TR capacity cooling tower all as specified and directed.
M&L for preparation of surface by scrapping and removing rusted portion with wire brush and applying one coat of synthetic eneamenl spray paint for complete refrigeration system, in-let/outlet pipe lines, compressors unit, condenser, pumpset control LT panel board duct covers, cooling tower stand including lettering & numbering and applying one coat of white /colour wash to chiller pipe line all as specified and directed Note : 03x140, 03x100 & 04 x 48 TR AC Plants along with all connected acessories as described above.
Repair to humidity control system and of ac plant capacity 3 X40 TR re-heating system and renewal only the defective unserviceable components, burned cable, wirings, and safety control devices, air strips heaters, humidistal, wets bulb thermostats heating and safety thermostats contractors, isolator and rewiring with required copper cable/wire as per the sequence of operation, in automatic operation of humidity control system. Inter lock through the nsafety control and AHU motor starter and testing commissioning the system to maintain the relative humidity of 65 ± 5% at conduction area all as specified and as directed.
All as per Item No.50 herein before but AC plant capacity 3 X140 TR
All as per Item No.50 herein before but AC plant capacity 3 X100 TR
M&L for servicing of central control unit 3 X 16 HP capacity of VRF AC unit including dismantling the units carefully, chemical cleaning of cooling coils and refrigent pipe lines with approriate cleaning agents, flushing through for proper air flow across the coils to improve the cooling efficiency, reassembling and re-installing the units in their original position complete all as per instructions of OEM and as directed . ( NOTE: Compressor and refrigerent gas if required shall be measured and paid separately)
Supply only 54P Compressor CCM SCJ666K3601
Supply & fixing high power LED Flood light fitting 150W complete ( mainting minmum system lumen-13700) on 11 mtr poles with IP protection 65 of Model No. JETA PROPLUSFL150WLED757LTG of Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
THE VENKATESWARA SUPPLIERS
Srinivash Engineers
SRK PROFESSIONAL ENGINEERING
SRIESWARI ENTERPRISES
M/s SS Engineering Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .