Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.0 Cr+₹99,874 (1.00%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical C O GALA RAM BORO VILL P O RATANPUR P S TANGLA DIST UDALGURI BTC ASSAM PIN 784523 | RATANPUR | UDALGURI | ASSAM | 784523 | - | Rejected-Technical Not Qualified |
Tender Value
₹99.7 L
EMD Value
₹2.0 L
Closing Date
12 Apr 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Infrastructure Development in Khoirabari College, Khoirabari in Udalguri.
2023_BTC_30137_1
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works - Building
Works
365 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
₹2.0 L
Yes
16 May 2023
27 Mar 2023
12 Apr 2023
27 Mar 2023
12 Apr 2023
27 Mar 2023
27 Mar 2023 - 12 Apr 2023
Amount
2.8. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
4.1.6. 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
11.3. Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate.
5.22. Steel reinforcement for R.. Work including sraitaning, leaning utting and bending to proper shape planing in position and binding up to plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
5.9. Centering and shuttering including strutting, propping etc end removal of the 5.9.1 Foundation Footing, base of column etc. for mas concrete.
5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6. Columns, Pillars, Posta & Strut
5.9.3. Suspended floors, roofs, landings, balconies and acces platform
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cont of centering, shuttering, finishing and 5.1.3 1:2:4 (1 cement: 2 coarse sand ( zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natu ral sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 ( 1 cement :4 coarse sand )
2.25.(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
13.3. Providing and applying plaster of pairs putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.5. 15 mm thick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4. (1 cement : 4 coarse sand)
13.4. Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1. water thinnable cement primer
13.4. Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1. New work ( Two or More coat @ 3.84
9.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) 9.1.3 Kiln seasoned and chemically treated hollock wood.
9.5. Providing and fixing panelled or panelledand glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. ( Note:- Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood 9.5.2.1 35 mm thick.
9.55. Providing and fixing ISI marked M.S. pressed butthinges bright finished with necessary screws etc. complete:
9.63. Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete:
9.66. Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete:
9.48. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
11.41 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size 11 414 1 1 Sin of Tile 600x600 mm
13.48. Painting Steel work with Deluxe Multi Surface Paint to give an ven shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture.
ELECTRICAL WORK 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core etc. as required. 1.10.1 Group A
1.10.2. Group B
1.1.3 Group C
1.14. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class conduit as required. 1.14.2 2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth wire
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.4 2 x 6 sq. mm + 1 x 6sq. mm earth wire
1.14.4 2 x 10 sq. mm + 1 x 6sq. mm earth wire
1.21:- Supplying and fixing following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20mm
1.24. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but exluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.3. 15/16 A switch
1.24.4.3 pin 5/6 socket outlet
1.24.5. 6 pin 15/16 A socket outlet
1.24.8. Bell push
1.25. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
1.28. Supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2. 3 Module
1.28.5. 8 Module
1.33. Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34. Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.44. Installation, testing and commissioning of ceiling fan, including writing the down rods of standard length (upto 30 cm ) with 1.5 sq. mm FRLS PVC insulated, copper conductor,single cvore cable etc. as required.
2.3. Supplying and fixing following way, single pole and neutral, shee steel, MCB distribution board, 240 V, on surface/ recess. complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1. 6 way, Double door
2.4. Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing, din bar, interconnections, power painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4+ 12), Double door.
2.10. Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.3. Double pole
2.12. Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40A
2.13 :- Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.3. 100A
5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having looking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
5.5. -Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
5.11. Providing and fixing 25 mm x 5mm G.I strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. As required.
5.17. Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
7.1.Laying of one number PVC insulated and PVC sheathed / XL power cable of 1.1 KV grade of following size direct in grol including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 upto 35 sq. mm
MR-1:-Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
MR-2:- Supplying with including fitting fixing Of tube light etc. as directed by the Deptt. (Bajaj make) Code No. 11249 luminaries type 18 WH white.
MR-3:- Supplying with including fitting fixing of LED Bulb 12 Watt. Etc. as directed by the Deptt. (LED home lighting Solution.)
MR-4:- Supplying with fitting fixing including laying "Mescab" 1.1 KV gd Al. Conductor XLPE insulated armoured PVC outer sheathed control/power cable confirming To IS: 7098 (Part-I) 1554 (Part-I) 1988 with amendments as applicable 16.00 mm² 4 core cable Conforming 100 mt
MR-5-Supplying fitting fixing 1.1 KV gd aluminium conductor XLPE insulated armoured/ un armoured PVC outer sheathed/ Power cable conforming to IS: 7098 (Part-1) 1554 (Part-1) 1988 with latest armoured mordis as applicable make MESCAB Considering 100 mtrs.
MR-6-Supplying and fitting fixing 2 H.P. Single phase Centrifugal Mono block Pump set sync speed 2900 mp. Model No. KDS- 213 with DOL Starter Control & switch gear (/ BCH/L&T/Siemens/ equivalent make). With all accessories complete as required and as directed by the department.
MR-7- Design, fabrication & supply of Floor mounted compartmentalized dust and vermin proof power distribution panel board (LT-3 ph, 415 V, AC 250 Amp) made of M.S. sheet of not less than 16 swg duly welded & Powder Coated with Grey colour to both in interior & exterior. All wiring for control & metering shall be done by multistranded PVC insulated Finolex make single core copper flexible cable of not less than 1.5 sq. mm. Size and will be properly harnesses and drawn neatly clamped for incoming & out going cable, 4 (Four) separately electrolytic grade copper busbar (3 phase & Neutral) of 300 amps will be layed in separate chamber. All the outgoing cable of the MCCB/MCB up to cable alley connecter shall be connected by flat/round/flexible Copper cable etc.
MR-8- Payment to be made to the APDCL Authority for Load security.
Mwikwm Basumatary
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .