Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.7 LAccepted-Finance NA | NA | NA | 121004 | ₹84.7 L | L1 | Accepted-Finance L1 |
| 2 | L2₹84.7 L+₹8,484.93 (0.10%)Rejected-Finance MAHADEV COLONY BALIYAKHEDI BLOCK NEAR GUJAR BHAWAN HASANPUR CHUNGI DELHI ROAD SAHARANPUR | ₹84.7 L+₹8,484.93 (0.10%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Reject |
Tender Value
₹1.0 Cr
EMD Value
₹2 L
Closing Date
7 Mar 2025, 5:00 pmClosed
Executive Engineer
Office Of The Executive Engineer Irrigation Division Dehradun
Construction of 3.50 km long canals in the command of Mianwala Canal, Doiwala Block, Dehradun District under NABARD Reach- minyawala Minor Kulawa No 03,04,05,07,08,14 (Job-4)
2025_IRDCE_80592_4
03/EE/2024-25
Open Tender
Civil Works
Item Rate
180 days
Mianwala Dehradun
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer Irrigation Division Dehradun
₹2 L
Office Of The Executive Engineer Irrigation Divisi
15 Apr 2025
22 Feb 2025
10 Mar 2025
22 Feb 2025
7 Mar 2025
22 Feb 2025
22 Feb 2025
Amount
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing
Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C grade M 10Nominal mix 1:3:6
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C. grade M 20 Nominal mix (1:2:4)
Plastering with cement mortar (1:4), 15 mm thick in substructure as per technical specification Clauses 613.4 & 1204
Plain/reinforced cement concrete in substructure complete as per drawings andtechnical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204R.C.C. grade M 25
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructruecomplete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Steel work welded in built up section/framed work including In gates and similar works,Regulation Shutter Size (0.40x0.50)M
HARVIR SINGH (BID ID -364013)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .