| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.1 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹59.4 L+₹1.3 L (2.23%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹69.6 L+₹11.5 L (19.7%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹76.3 L
EMD Value
₹77,000
Closing Date
13 Dec 2023, 11:00 amClosed
SE EDC RAMPUR
office of the SE EDC RAMPUR
48/2023-24/EDCR Increasing load capacity of overloaded Transformer, replacement of VCB, Jarjar wire construction of line under Business Plan, EDD-I, Rampur.
2023_PVVNL_866653_1
48/2023-24(EDCR)
Open Tender
Electrical Works
Lump-sum
30 days
office of the SE EDC RAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC RAMPUR
₹77,000
3 Jul 2024
1 Dec 2023
13 Dec 2023
1 Dec 2023
13 Dec 2023
1 Dec 2023
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
33 KV VCB 800/750 Amp
33 KV PT O/D
Control Pannal I/C for 33 KV Double T/F
33 KV CT/PT
11 KV VCB I/C Feeder CTR 600/300/5A
11 KV VCB O/G Feeder CTR 200/100/5A
STP 11 Mtr Long
PCC 8.5 Mtr Long
11/0.4 KVA T/F 400 KVA
11/0.4 KVA T/F 630 KVA
11/0.4 KVA T/F 250 KVA
11/0.4 KVA T/F 100 KVA
ACSR Dog Conductor
ACSR Weasal Conductor
LT XLPE Cable AL 1x630 sqmm
LT XLPE Cable AL 1x240 sqmm
LT XLPE Cable AL 1x400 sqmm
LT ABC Cable (3x120+1x95+1x16) sqmm
LT ABC Cable (3x95+1x70+1x16) sqmm
LT ABC Cable (3x50+1x35+1x16) sqmm
LT XLPE Cable 3.5x150 sqmm
Polymeric 11 KV Pin Insulator
Polymeric 11 KV Disc Insulator
11/0.44 KV 100 KVA T/F(old & used)(Recived Back Site to Store)
11/0.44 KV 250 KVA T/F(old & used)(Recived Back Site to Store)
11/0.44 KV 400 KVA T/F(old & used)(Recived Back Site to Store)
ABC cable(Recived Back Site to Store)
Old CT(Recived Back Site to Store)
33 KV CT/PT(Recived Back Site to Store)
Weasel Conductor (Recived Back Site to Store)
VCB Scrap(Recived Back Site to Store)
AI Scrap (in KG)(Recived Back Site to Store)
Dismantling of HT & LT connection & replace of follwoing capacity T/F from substation double poles/plinth by Healthy transformer(including connection) and loading and unloading with associated work at both ends within 70 kms.
overloaded 100 KVA trasnformer
overloaded 250 KVA trasnformer
overloaded 400 KVA trasnformer
Installing of Healty Transformer, connection HT & LT of follwoing capacity T/F at substation Single Pole/ double poles/plinth by Healthy transformer(including connection) and loading and unloading with associated work at both ends within 70 kms.
Increasing load capacity of overloaded by 100 KVA trasnformer
Increasing load capacity of overloaded by 250 KVA trasnformer
Increasing load capacity of overloaded by 400 KVA trasnformer
Increasing load capacity of overloaded by 630 KVA trasnformer
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
11 Mtr long STP Pole
8.5 Mtr long PCC Pole
b) Double pole structure Excavation of foundation pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole)Erection of support(pole) complete with providing and fixing of all clamps made of MS flat of size 75x8 mm. an other accessories . The work includes fabrication work and fixing of cross bracing sets 3.5 Mtr from MS Angle 65x65x6 mm/50x50x6 mm. The work includes cutting holes and providing MS Bolts of 16x40 mm size in the middle of the cross bracing with 1 No. sparing washer of proper size.
11 Mtr long STP Pole
8.5 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
11 Mtr long STP Pole
8.5 Mtr long PCC Pole
b) Double pole structure
11 Mtr long STP Pole
8.5 Mtr long PCC Pole
Providing & Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Providing and Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs (Earting complete( Rod and wire) will be provide by the contractor)
fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling Jarjar wire and laying ,stringing and binding of ACSR Weasal Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Dismentling Jarjar wire and laying ,stringing and binding of ACSR Dog Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT XLPE Cable AL 1x630 sqmm as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT XLPE Cable AL 1x240 sqmm as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT XLPE Cable AL 1x400 sqmm as per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling jarjar wire and Laying ,stringing and binding LT ABC Cable (3x120+1x95+1x16) sqmm per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling jarjar wire and Laying ,stringing and binding LT ABC Cable (3x95+1x70+1x16) sqmm per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling jarjar wire and Laying ,stringing and binding LT ABC Cable (3x50+1x35+1x16) sqmm per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of LT XLPE Cable 3.5x150 sqmmm per RESPO Norms and as per direction of Supervising Engineer.
Installing of 33 KV VCB 800/750 Amp as per RESPO Norms and as per direction of Supervising Engineer.
Installing of Control Pannal I/C for 33 KV Double T/F as per RESPO Norms and as per direction of Supervising Engineer.
Installing of 33 KV P/T Outdoor as per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling old CT/PT and Installing of 33 KV CT/PT as per RESPO Norms and as per direction of Supervising Engineer.
Installing of CTR 200/100/1-1A as per RESPO Norms and as per direction of Supervising Engineer.
Providing and Installing of TPMO as per RESPO Norms and as per direction of Supervising Engineer.
Installing of 11 KV VCB I/C Feeder CTR 600/300/5A as per RESPO Norms and as per direction of Supervising Engineer.
Installing of 11 KV VCB O/G Feeder CTR 200/100/5A as per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling of old VCB as per RESPO Norms and as per direction of Supervising Engineer.
Dismentaling of Old CT as per RESPO Norms and as per direction of Supervising Engineer.
Construction of plinth for 250 KVA/400 Transformer 2x2x1.5 M with fencing as per RESPO Norms and as per direction of Supervising Engineer (Material for plint and fencing will be provide by the Contractor)
Construction of plinth and foundation for VCB as per RESPO Norms and as per direction of Supervising Engineer (Material for plint and fencing will be provide by the Contractor)
Providing and installing 1-Phase Distribution Box as per RESPO Norms and as per direction of Supervising Engineer
Providing and installing 3-Phase Distribution Box as per RESPO Norms and as per direction of Supervising Engineer
Providing and laying of Control Cable 2*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and laying of Control Cable 4*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and laying of Control Cable 10*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and laying of Control Cable 6*2.5 sq mm as per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Stone pad
Providing and fixing 11 KV X Arm MS Angle 65*65*6 mm with clamp
Providing and fixing MS Channal (Dropper) 100*20*2028 mm
Providing and fixing MS Channal(Top) 125*65*2240 mm
Providing and fixing Clamp with Nut bolts
Providing and fixing Danger Board with Fixing Clamp
Providing and fixing Barbed wire
Providing and fixing dead and clamp
Providing and fixing S/S Angle
Providing and fixing LT Clamp
Providing and fixing PG Clamp
Providing and fixing Suspension Clamp
Providing and fixing Piercing Connector
Providing and fixing Holding Clamp
Providing and fixing T-off channel with clamp
Providing and fixing fuse set
Providing and fixing lightening arrestor
Providing and fixing shckle insulator
Providing and fixing GM connector
Providing and fixing AL Lug for 120 sqmm
Providing and fixing AL Lug for 400 sqmm
Saraswati Electricals & Contractors
S A TRADERS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .