Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Closing Date
27 Nov 2026, 3:00 pmDue tomorrow
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Director, ACTREC
ACTREC, Kharghar
EOI FOR AUTOMATED LIQUID HANDLING SYSTEM FOR SERIAL DILUTION
2026_TMC_934240_1
ACTREC/PUR/2026-27/EOI/007
Open Tender
Equipments (Hospital / Lab)
EOI
ACTREC, Kharghar
Please refer Tender Document
1 document required · 1 mandatory
₹0
Exempted
13 Nov 2026
13 Nov 2026
28 Nov 2026
13 Nov 2026
27 Nov 2026
13 Nov 2026
180 days
"Automated Pipeting System " , complete as per below mentioned configuration and specifications:
System Integration
Hardware & Fluidics Specifications
Software Control & Data Security
Additional System Accessories
IQ/OQ/PQ should be provided
Provide the list of proprietory consumables if any for the quoted equipment along with the technical bid (Not to include price as it may lead to disqualification) If no list is provided, it implies that there are no proprietory consumables.
Standard accessories (Which comes along with the machine, pricing of which is part of the equipment)
The Equipment should comply to US FDA/ European CE/ BIS/ ICMED certification. Please attach copy of the certificate(s).
User's list: A list of installations with the address and contact numbers to be provided. (User list should be for the quoted model.)
Input power supply requirements: 240 V AC ± 10 %, 50 Hz, single phase. Specify if any other power supply requirement is recommended.
Vendor to submit power consumption.
On-Line UPS requirements , If required should be provided with the system .
After Sales Service Support.
1. Complete technical information should be provided. 2. Company should provide technical support for hardware and software, spares and consumables. 3. Company should provide required spares and consumables for at least 10 years even after discontinuation of the model. 4. Manufacturer should have its authorised service provider's office located in Mumbai or Navi Mumbai area. Service provider should have adequare strength of service personnel trained on servicing and maintenance of the quoted model. Bidders who do not qualify this critera shall not be considered. Bidder should provide address of the authorized service centre and details of number of personnel with training credentials and authorization certificate should be provided.
Installation, Commissioning, testing and Training
Unpacking and Shifting the consignment to the installation site is to be included in the scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift/shift the consignment from unloading site to the installation site . Unloading site shall be "Stores Department, KS Building, ACTREC Campus". If needed, Bidder has to arrange for the labourers at no charge to ACTREC. (Before submitting the quotation, bidders may visit ACTREC to know unloading site and installation site)
Warranty and after sales support
Warranty- 2 years
CMC- cost per annum will be considered for all bidders for 8 years after warranty
Warranty and CMC :- Should include a) Two Preventive maintenance/ year and unlimited breakdown calls along with spares.b) All bought out items quoted along with the main system (local/non-local) and UPS should be covered. c) Yearly calibration/Validation/QA, Testing and measuring equipment used should be traceable to SI units through National/ International standards (as per NABL/NABH norms). d) PM kit if any. e) All upgrades/update, no seperate licence fees will be payable.
Manufacturer/bidder should clearly indicate typical life span / Life expectancy of the quoted equipment.
Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]
After opening of the Technical bid (Part-1), Physical demonstration of the quoted model may have to be shown / arranged by the bidder, if requested by the Institute. Physical demonstration may be shown at one of the end user’s site/Principle company’s application lab/manufacturing site located in MMR region. If there are no installations of the quoted model in MMR region, then the quoted model may have to be brought in at ACTREC for demo purpose within 10 days from the date of request. Physical Demonstration may be requested to confirm the availability of any or all technical features as mentioned/stated in the technical bid. Physical Demonstration will also be a part of technical evaluation process. If the bidder does not comply, such bids are liable to be disqualified. (Demonstration of quoted model is to be shown and not the demonstration of similar models with different technical specifications and features)
L1 Calculation:
L1 will be based on cost of the entire system + 8 years CMC cost + PART-B Consumables cost and other support equipment at landing cost at ACTREC i.e.. Equipment cost, applicable taxes and duties, transportation & insurance charges, installation charges along with 5 years warranty cost.
GTE Availability:
OM Number:
End User (HOD) Sign Biomedical Engineer Sign MS/Project Co-ordinator Sign
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Techspec2.xls
Tender Documents • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .