Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹36.0 L
EMD Value
₹50,000
Closing Date
25 Nov 2023, 4:30 pmClosed
Executive engineer
EE,KWA Project division chittur
JJM-WSS TO CHAKKUPAADI IN WARD 10 OF N E L L I Y A M P A T H Y GP CONSTRUCTION OF OPEN WELL, PUMP HOUSE, SUPPLY AND ERECTION OF MOTOR PUMP SET, LAYING PUMPING MAIN, PROVIDING STORAGE TANKS, DISTRIBUTION SYSTEM AND TAPS
2023_KWA_623048_1
24/2023-24/EE/PD/CTR
Open Tender
Civil Works - Others
Item Rate
60 days
NELLIYAMPATHY
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,760
Yes
₹50,000
Yes
8 Mar 2024
18 Nov 2023
27 Nov 2023
18 Nov 2023
25 Nov 2023
18 Nov 2023
Amount
APPENDIX - I - CONSTRUCTION OF OPEN WELLS
100.3.5.1:Earthwork in open well excavation (above water) for wells of diameter above 3.5m and up to 6.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.6.1:Earthwork in open well excavation (above water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.6.2:Earthwork in open well excavation (above water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.0m including neat banking.
100.3.6.3:Earthwork in open well excavation (above water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.50m including neat banking.
100.3.6.14:Earthwork in open well excavation (in or under water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 4.5m to 6.0m including neat banking.
100.3.6.15:Earthwork in open well excavation (in or under water) for wells of diameter above 3.5m and up to 6.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.50m including neat banking.
OD161382/2023-2024:Protected blasting in Hard rock (in or under water) for wells - 7.50m to 9.00m depth
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
APPENDIX - II - PROVIDING PRE FABRICATED RCC PUMP ROOM
OD161384/2023-2024:Towards the charges for providing pre fabricated RCC cabin pump house of inside dimensions of 1.5m*2m, having height of 2.1m, flooring with PCC 1:3:6 - 10cm thick etc. including cost conveyance and all labour charges etc. complete
APPENDIX - III - SUPPLY AND ERECTION OF MOTOR PUMPSET
OD161385/2023-2024:Supplying and Erection of 3HP Open well submersible (Horizontal type) pump set having Head 45m and Discharge 2lps for Pumping Clear water from the open well to OHSR- ( 1Nos +1No) - 2Nos - One stand by best quality I S I mark KWA approved make, 960-3000 rpm, Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling. Centrifugal horizontal end suction pump upto 10HP.
OD161386/2023-2024:Motor, Supply, erection, testing and commissioning of KWA pre-Qualified reputed make horizontal solid shaft, foot mounted TEFC squirrel cage induction motor suitable for 3HP pump working 3 phase 50 Hz AC, supply, working voltage 415 V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. Digital motor protection relay shall be included in starter as present IE rules. Flexible coupling shall be used for coupling of pumps and motors - Say 3KW Horizontal TEFC squirrel cage 4pole induction motor
OD161387/2023-2024:Starter supply, erection, testing and commissioning of suitable rating star delta starters (Upto 10HP) suitable for the above motor with over voltage and under voltage protection, single phase preventer, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc. complete
18.10.6:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
OD161421/2023-2024:Providing specials for inter connection such as Bend, Tee, Union etc.
APPENDIX - IV - SUPPLYING AND LAYING CLEAR WATER PUMPING MAIN
100.98.234:Supply of PVC Pipe, 10kg/cm2, 63mm Dia.
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
OD162208/2023-2024:Supplying specials for 63mm PVC pipes 10kg (3% of pipe cost)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
18.10.3:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall25 mm dia nominal bore
18.10.6:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
OD161390/2023-2024:Providing and fixing 200mm dia or nearest size protection tube/AC pipe bit or PVC pipe bit for a length of 1.50m long for protection tube to the below 150mm valve and Air valve in the pipe line /distribution system
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
APPENDIX - V - PROVIDING 5000 LITRE CAPACITY HDPE TANK OVER MS PLAT FORM
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
APPENDIX - VI - DISTRIBUTION SYSTEM AND PROVIDING FHTCs
100.98.211:Supply of PVC Pipe, 6kg/cm2, 63mm Dia.
100.98.212:Supply of PVC Pipe, 6kg/cm2, 75mm Dia.
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
OD162234/2023-2024:Supplying specials for 63mm PVC pipes 6kg (3% of pipe cost)
OD162235/2023-2024:Supplying specials for 75mm PVC pipes 6kg (3% of pipe cost)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
18.10.3:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall25 mm dia nominal bore
18.10.6:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
18.12.7:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
OD161395/2023-2024:Providing and fixing 200mm dia or nearest size protection tube/AC pipe bit or PVC pipe bit for a length of 1.50m long for protection tube to the below 150mm valve and Air valve in the pipe line /distribution system
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
100.60.1.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
100.60.10.1.1:Providing 15mm (1/2 inch) GM Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
100.60.23.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm ( 1/2 inch ) water connection, using 20mm ( 1/2 inch ) Indian Standard uPVC Class 6 pipes, uPVC specials and PP PN 16 Compression specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
18.10.5:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall40 mm dia nominal bore
OD161396/2023-2024:Providing stand posts for house connection/Public taps
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
Bidder Name
Dillep
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .