Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹13.2 L+₹1.5 L (12.5%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 |
Tender Value
₹12.1 L
EMD Value
₹24,200
Closing Date
26 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KARGIL
OFFICE OF THE GE KARGIL LADAKH
SPL REPAIR WORKS TO BLDG NO T-17 AND T-18 TSTS LIVING BARRACK OF 260 TRANSIT CAMP AT BUDHKHARBU UNDER GE KARGIL
2022_MES_540955_1
GE/K-29/2022-23
Open Tender
Civil Works
Item Rate
180 days
BUDHKHARBU
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KARGIL
₹24,200
Yes
26 Sept 2022
28 Jul 2022
29 Aug 2022
28 Jul 2022
26 Aug 2022
12 Aug 2022
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge.
S & F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or brads complete all as specified and directed.
S & F 25 mm thick second class teak wood beading rectangular/square /rocked in shape weight finished of size no exc 3 sqcm fixed with screwed duly frenched polished (two coats ) all as specified and directed.
S & F 12mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination on both sides, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
S & F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed.
M & L for second class hard wood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge.
S & F second class hard wood (KAIL) plain, framed, panelled shutters (any number of panels), 35 mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercial veneering both faces as in doors, complete all as specified and directed by Engr-in-Charge.
S & F second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. complete all as specified.
S & F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified.
S&F 100 mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed.
S&F anodised aluminium barrel tower bolt extruded sections 200 mm size complete all as specified and directed.
S&F anodised aluminium barrel tower bolt extruded sections 100 mm size complete all as specified and directed.
S&F 150mm long, Aluminium handles, cast type,anodised complete all as specified and directed.
S&F Mild steel sliding door bolt 300 mm long plate type slove enamelled black wioth bright bolt not less than 12mm dia with and incl a minimum of 6 bolt and nut four on bolt plate and two on staple plate and fixed.
M&L for preparing previously untreated wood and wood based material of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of pink primer including preparation of surface.
M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface.
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M & L for colored joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match pointed in white or coloured cement to match complete all as specified and directed.
Demolition of concrete of any description and in any position and removal of rocks/debris to a distance not exc 50 mts and depositing where directed at a level n exc. 1.5 m above the starting point.
M & L for 75 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified.
M & L for chequered cement concrete tiles 20x20x25mm thick, with grey cement and no pigments, set, jointed and pointed in neat cement slurry in floors including 15 thick screed bed in CM ( 1:6) all as specified.
Demolition of precast concrete articles and precast concrete block walling including all quoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking outjoints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15mm thick cement plaster in cement mortor (1:4) finished even & fair without using extra cement on brick/concrete surfaces.
M&L for two coats of cement based paint on newly plastered surfaces of walls including preparation of surfaces.
S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
M&L for point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box/PVC box, surface/ flush type with 3 mm thick pre laminated hylem sheet for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc as specified and directed by Enginneer-in-charge.
All as per item No.37 above but for multi 5 pin 5 amps flush type socket outlet on same board.
All as per item No.37 above but for multi 5 pin 5 amps flush type socket outlet on independent board.
All as per item No 37 above but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for 5 pin 15 amps multi pin flush type socket outlet on independent board.
S&F switch piano flush button single pole one way 5 amps.
S&F 5 pin switch socket combination outlet flush 5 pin type 5 amps on same board.
S&F switch socket combination outlet 2 in 1, 3 pin, flush piano type universal 15 amps controlled by one switch on independent board.
S&F ceiling rose on PVC square Blocks surface bakelite 3 terminal.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fix in replacement MCB Distribution board , 240 volts single pole and neutral ,single door, sheet steel, enclosure powder coated with 200Amps rated busbar with neutral link, 4 ways, SPN QVE Serics , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed by Engr-in-Charge.
S&F MCB SP 240V, 10 KA, C Series and current carrying capacity in the MCB DB complete with connection testing and commissioning of single pole size 06 to 32 amp.
S&F MCB SPN 240V, 10 KA, C Series and current carrying capacity in the MCB DB complete with connection testing and commissioning of single pole size 40 amp.
S&F 1100 volts grade heavy duty 16 sqmm 2 core flat cable PVC insulated aluminium stranded conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire withtwo single core cable complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply & fix LED building security light 45 watt energy efficient with bracket,suitable dia pipe for fixing the street light in wall all as directed.
Note :(i) Deduction for amount of Rs 17,359.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract. (ii) Building Works Should be carried out as per TD approved by CELZ.
M/S ABASS ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .