| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.9 L+₹20,090 (0.46%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹44.9 L+₹1.2 L (2.78%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹48.8 L+₹5.1 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
16 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
Spl repair to bldg No P-19 T-54 T-03 T-17 T-74 T-80 construction of septic tank and minor work under AOR of AGE BR Dett III at Rajouri
2021_MES_414271_1
GER-72/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹98,000
Yes
10 Mar 2021
19 Jan 2021
18 Feb 2021
19 Jan 2021
16 Feb 2021
2 Feb 2021
60 days
Amount
Sch 'A' Part-I (B/R Works) Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
75/100mm thick PCC 1:5:10, type E-2 using 40mm graded stone aggregates as in sub base of floors, laid to level complete all as specified and directed.
50mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
Taking down steel rolling shutter of any size with complete arrangement from wall and remove to store complete all as specified and directed.
Steel rolling shutters, 1mm thick lath without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on other than fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of cement primer complete all as specified and directed.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of cement base paint over and including a coat of cement primer complete all as specifed and directed.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of oil bound distemper over and including a coat of cement primer complete all as specifed and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Dismantling of corrugated or semi corrugated asbestos cement sheets roof coverings complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Preparation of old steel surface and applying two coats of synthetic enamel paint any tint including prepartion of surface complete all as specified and directed.
Preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410W complete all as specified and directed.
25mm thick PCC type B1 1:2:4 (using 20mm graded aggregate) as in sub floor, finished even & fair complete all as specified and directed.
Machine cut Kota stone slab flooring 20-25 mm thick as in flooring area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid over & including 20 mm thick cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and grinding to achieve mirror finish complete, all as specified and directed.
Machine cut Kota stone slab flooring 20-25 mm thick as in risers of steps, skiring dado and pillar , area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid over & including 20 mm thick cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and grinding to achieve mirror finish complete, all as specified and directed.
Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each and removing to store complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles of size 400x400x7mm /350x 250x7mm or 450x350x7mm thick as on vertical surface of wall such as skirting, dado, riser etc,set over 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and as directed.
1000 ltr capacity three layer (ISI marked) rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Taking down steel window/ventilatrs of any size complete removal from site complete all as specified and directed.
Steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
4mm thick figured glass ordinary quality and glazing with oil putty/wooden beads in square in any size complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, chromium plated, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
15mm bore stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Vitreous China wash hand basin in repair oval special type 510x410mm including fency type pillar taps including PVC waste pipe, PVC connection and waste coupling complete all as specified and directed.
PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
125mm brass chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2010 complete all as specified and directed.
Stainless butt hinges medium weight 100mm in size for PVC doors complete all as specified and directed.
Extruded aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for fdn etc and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
PCC type B-1 (1:2:4), using 20 mm graded stone aggregates in surface channels and drains complete all as specified and directed.
Extra for forming fair finish to drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed
Looking mirror of size 1600x600x6mm fixed with holding clips/nuts botls alongwith wall complete all as specified and directed.
20 mm thick granite stone slab of any type with table rubbed and polished in cooking platforms and like, set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab, rounding edges etc complete all as specified and directed.
100mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm on vertical surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, fixed over and including 15 mm thick backing layer of cement plaster in CM 1:4 complete all as specified and directed.
Rendering 20mm thick on stone masonry or other than fair faces of brick wall in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick on stone masonry or other than fair faces of brick wall in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick in CM 1:4 over/soffit of chajja finished surface even and smooth without using extra cement complete all as specified and directed.
Preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of old wooden surface exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating incuding necessary form work complete all as specified and directed.
Powder coated aluminium window/ventilator using 63x38x1.6mm chowkhats with necessary sliding rails as in 40mmx40mmx1.5mm thick shutter including ornamental aluminium grill, 5mm thick glass panes of approved make with rubber for fixing glass ans ss wire mesh including builders hardware such as side locks of best quality etc complete all as specified and directed.
Powder coated aluminium door using 96.6x44.8x1.6mm aluminium chowkhats 84.0x44.7x1.6mm section vertical style 101.60x44.8x1.6mm raised fixed with 4 Nos 125mm SS butt hinges, hydraulically door closer, mortice lock vertical type, aluminium tower bolts 2 nos of size 150mm , Aluminium sliding door bolt 30mmlong-01 Nos, door handles and fitting, bottom panel with 12mm thick laminated nova pane sheet and top panel with 5.5mm thick plain glass fixed snap beeding ruber of suitable size complete all as specified and directed.
Looking mirror of size 500x700x5mm fixed with holding clips/nuts botls alongwith wall complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified and directed.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
75mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand(all by weight) complete all as specified and directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound (Grade-A) complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling existing board complete all as specified and directed.
300mm MS ordinary rat tail spring of approved make including roller and roller plate complete all as specified and directed.
15mm dia two ways stop valve cast copper alloy chromium plated fixed iron pipe complete all as specified and as directed.
Demolition of cement concrete (reinforced in ground floors), beams stair cases, landing, chajjas and similar suspended work including cutting of reinforced and disposal off MoD land complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust nd brushing neat cement slurry @ 3 kg/Sqm of cement complete all as specified and directed.
White Marble 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 15mm screed bed in CM 1:6 complete all as specified and directed.
3mm thick sheet glass ordinary quality and glazing with oil putty/wooden beads in square in any size complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
Aluminum alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Aluminium anodised Hasp and staple 100mm safety type with stainless steel pin fixed with screws complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 20 mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
Welded steel wire fabric supplied and fixed complete to wood or steel members weight per sqm n exc 4 kg complete all as specified and directed.
Butt hinges 100mm heavy weight cold rolled mild steel complete all as specified and directed.
Construction of septic tanks exc in ordinary soil foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers inlcuding RCC precast manhole cover having 6mm plate embedded all and sludge chambers reinforced cover with angle iron frame vent shaft around/fibre etc complete for 100 user complete all as specified and directed and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
Construction of soakage well 3.6 Mtr dia and 3 M deep including excavation and earth work in any type of soil, PCC 1:3:6 in foundation, walls of honey combed masonry with top ring of M-30 concrete including intercerpting chamber and screen chamber made of Brick masonry in CM 1:4, RCC cover slab in M-30, interconnecting pipes of RCC complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe complete all as specified and directed.
150 mm internal dia Salt-Glazed stone ware drain pipes laid in trenches over concrete bedding jointed in cement mortar 1:1 and tested complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement including mixing of water proofing compound as per manufracturer's instructions complete all as specified directed.
Supply only integral water proofing compound complete all as specified and directed.
Pre-cast cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for cover slab, manholes etc, set in CM 1:4 complete all as specified and as directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 108 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 108 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 108 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
Socket out let 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 15 watt complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or its equivalent technically and commercially in Philips/Havells/Bajaj/Crompton
Supply and fixing in repairs sheet metal enclosure MCB distribution board triple pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification(Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Supply, Laying, connecting and testing in replacement of service cable of size 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete all as specified and directed.
Street light fitting LED 25 watt made up of grey powder coated pressure die cast aluminium housing having IP66 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTS-25-CDL or its commercially and technically equivalent in Bajaj/Philips/Havells/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, connected to and including earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type C-2 & precast RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion complete all as specified and directed.
Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. Cat part No HEXAFT10WLED857SSYMBOPC,Make-Havells or equivalent model in Bajaj, C&S
Supply, Laying, connecting and testing in replacement of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete all as specified and directed.
House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy complete all as specified and directed.
Ceiling fan 1200mm sweep with 5 star rating electrical operated 220 volts 50 HZ AC supply complete with hook arragnement for hanging with canopy and rod complete with all accessories including regulator etc Make - Bajaj or USHA /Havells/CG
Storage water Heaters verticle type ( Geysers) of cap 50 Ltrs , 5 star rated as per BEE norms electrically operated suitable for 230 volts , 50 HZ AC supply system complete with porcelain/glass coated insulated heating element, copper inner tank, external thermostate including CP connections grouting of suitable nut, bolts etc complete all as specified and directed. Make Bajaj shakti /CG/ Venus/ Ditz.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including 25mm dia rigid PVC conduit and conduit accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of conduit shall be measured as one unit.
Sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 20 amp complete all as specified and directed.
Point wiring for (Modular switchs) one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC rigid concealed conduit 20/25 mm medium grade ISI marked complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 133 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 133 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 133 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Modular switch 1 way 6A, 1 module complete all as specified and directed.
Modular switch 1 way 16A, 1 module complete all as specified and directed.
Socket, 6A - 2/3 pin combined 2 module complete all as specified & directed.
Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Fan step regulator, 120W - 2 module complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 09 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F09WLED P/W or its equivalent technically and commercially in Philips/Havells/Bajaj/Crompton
High efficacy 2'x2' recess LED flat panel light 36W LED 2700/3000K (warm white) edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Havells/Bajaj/Crompton/Halonix.
Supply and fix decorative wall mounting round type dia 70mm chrome finish fixture with frosted glass suitable for 3W LED warm white lamp 3000K including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. Make :- Havells or equivalent model in CG, C&S or orient
Supply and fix decorative wall mounting round type dia 62mm chrome finish fixture with frosted glass suitable for 3W LED warm white lamp 3000K including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. Make :- Havells or equivalent model in CG, C&S or orient
Supply and fix in repair, factory made, sheet metal enclosure, double door, 415 volts, AC TPN, vertical distribution board 4 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160 Amps FP 16-36 KA and MCB SP/TP as outgoings and complete with and including 200 amps rated copper busbar, neutral bar earth bar connecting cable links with including top and bottom removeable gland plate complete with IP 43 protection complete all as specified and directed.
Supply and fixing in repairs sheet metal enclosure MCB distribution board triple pole & neutral 430 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification(Note-MCBs will be measured and paid for separately).
MCCB FP 63 Amps 10 KA 240 volts complete all as specified and directed.
Sub main wiring alongwith earth wire using 2x10 sqmm (colour coading) + 1x6 sqmm earth wire (green colour) of single core PVC insulated multistranded copper conductor 1100 volts grade FRLS type in and including casing caping complete all as specified and as directed. Note: 03 runs of cable and one run of conduit shall be measured as one unit.
Taking down ceiling fan/exhaust fan of any sweep of any make from its existing position, after disconnectioning electric conection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pin, cater pins, coupling bolt, capacitor holder, terminal adopto, screws nuts and washers etc and replacement of spare parts/accessories such as ball bearings gun metal bushes capacitor canopy top and bottom, shakle clip assembly, rewinding of fan motor, painting and including hanging fixing back in existing location aand making cable connection and testing for its satisfactory performance compete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 4 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Sand cushioning to underground cable, provided with a layer of 8 cm deep before laying the cable and 15 cm thick after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed
GI pipe 50mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S BADRI NATH GUPTA
SUBASH CHANDER
M/S Ashok Kumar Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .