Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
10 Apr 2026, 5:00 pmClosed
Director
The Director, IIITM-K, Technopark Phase I Kazhakuttom Thiruvananthapuram
Supply, Installation, Testing and Commissioning of ELV Work for library block with Data centre under Kerala University of Digital Sciences, Innovation and Technology at Technocity, Thiruvananthapuram.
2026_KUDST_844804_1
IIITMK/08/ELV LB/2026
Open Tender
Civil Works - Others
Item Rate
120 days
Digital University Kerala, Technopark Phase IV
Refer tender document
4 documents required · 4 mandatory
₹12,390
Yes
₹2 L
Yes
Digital University Kerala
6 Mar 2026
6 Mar 2026
13 Apr 2026
6 Mar 2026
10 Apr 2026
6 Mar 2026
6 Mar 2026 - 9 Mar 2026
10 Mar 2026
Laying and Jointing PVC Pipe. Heading
OD321400/2025-2026 Supplying, installing, testing and commissioning of 6 Core Single Mode Optical Fiber cable Armored with Anti Termite & Anti rodent as per specification.[For Ground Floor Main Rack to each floor Racks]
OD321419/2025-2026 Supplying, installing, testing and commissioning of 24 Port Fiber LIU complete with all accessories
OD321558/2025-2026 Supplying, installing, testing and commissioning of 12 Port Fiber LIU complete with all accessories
OD321646/2025-2026 Supplying, installing, testing and commissioning of Fiber Patch cord as per specification
OD321841/2025-2026 Supplying, installing, testing and commissioning of 24port L3 Switch, 24x25G Fiber Ports 4 X 40/100G with 2 no of 40G LR Transceivers, and 100G Active optical cable and as per specification
OD321854/2025-2026 Supplying, installing, testing and commissioning of SFP+ modules for 10 Gigabit Ethernet connectivity as per specification
OD322257/2025-2026 Supplying, installing, testing and commissioning of QSFP Modules of high density and low power 40 Gigabit Ethernet connectivity as per specification - To be Interoperable with existing core/distribution switch
OD322258/2025-2026 Supplying, installing, testing and commissioning of 48port POE+ Switch, modular uplink as per specification
OD322259/2025-2026 Supplying, installing, testing and commissioning of 24port POE+ Switch, modular uplink as per specification
OD322260/2025-2026 Supplying . Installing , testing and commissioning of Wireless Access Controller (as per Specification)
OD322261/2025-2026 Supplying, installing, testing and commissioning of Wireless Access point ( as per specification) with Licenses to connect with existing Controller
OD322262/2025-2026 Supplying, installing, testing and commissioning of IP phone Type-1 as per specification including all necessary items to connect with existing system
OD322263/2025-2026 Supplying, installing, testing and commissioning of IP phone Type-2 (High end) as per specification including all necessary items to connect with existing system
OD322264/2025-2026 for available Nos of IP Phone Licenses for the existing IPPBX Solution or Supply, Installation, testing and commissioning of IPPBX Solution with SIP Trunk Capability in High Availability
OD322270/2025-2026 Supplying and drawing of UTP 4 pair CAT 6A LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 1 run of cable
OD322275/2025-2026 Supplying, installing, testing and commissioning of Cat 6A Information outlet for data As per Specification
OD322276/2025-2026 Supplying, installing, testing and commissioning of Cat 6A Information outlet for voice As per Specification
OD322277/2025-2026 Supplying, installing, testing and commissioning of 48-Port Category 6A Patch Panel, 1.75”-High - Data As per Specification
OD322278/2025-2026 Supplying, installing, testing and commissioning of Cat 6A patch cord-7FB (User end) for Data As per Specification
OD322279/2025-2026 Supplying, installing, testing and commissioning of of Cat 6A patch cord-7FB (Rack end) for Data As per Specification
OD322280/2025-2026 Supplying, installing, testing and commissioning of Cat 6A patch cord-9FB (Rack end) for Voice As per Specification
OD322281/2025-2026 Supplying, installing, testing and commissioning of Cat 6A patch cord-9FB (User end) for Voice As per Specification
OD322282/2025-2026 Supplying, installing, testing and commissioning of 2-Port Faceplate with Labeling Windows As per Specification
OD322283/2025-2026 Supplying, installing, testing and commissioning of 4-Port Faceplate with Labeling Windows As per Specification
OD322284/2025-2026 Supply and Installation of back box 86mm*86mm for face plate
OD322285/2025-2026 Supply and Installation of 2U Panel Wiring Duct on Front (Cable Manager)
OD322286/2025-2026 Supplying, installing, testing and commissioning of 15 U Rack with standard accessories
OD322288/2025-2026 Supplying, installing, testing and commissioning of 24 U Rack with standard accessories
OD322289/2025-2026 Supplying, installing, testing and commissioning of 42 U Rack with standard accessories
4.6.2 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
4.7.2 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
4.8.2 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
CCTV SYSTEM
OD322300/2025-2026 Supply, installation, testing and commissioning of 1/2.9" 2.1MP CMOS Starlight Sensor Dome Camera with effective 1945(H) X 1109(V) pixels, 2.8 mm fixed lens, Video Compression H.265, H.264, M-JPEG, Color 0.25Lux BW, 0Lux with IR, IR Distance 60ft, 120dB WDR, Auto Iris, Dual Streaming, Frame rate 30 FPS on 1080p resolution, Smart video stream Compression, Auto / Manual ( 1/15 ~ 1/32000 ), Audio In, Anti- Flicker, Slow Shutter ( 2X, 3X, 5X, 6X, 7.5X, 10X ) 3D DNR, Motion detection, ONVIF S, Ethernet port 10/100 Mbps, 12DC, PoE, Metal body, IP66 and IK 10 protection, Certificate UL, BIS, CE, FCC & RoHS. 3 Years Standard Warranty.
OD322303/2025-2026 Supply, installation, testing and commissioning of 1/2.8'' 2.1MP CMOS Starlight Sensor Bullet Camera with effective 1945(H) X 1109(V) pixels, Motorized varifocal lens 2.8 mm to 12mm, Video Compression H.265, H.264,M-JPEG , Color: 0.02Lux)/F2.0, 0 Lux (IR On), Smart IR Distance 80ft, True WDR 120dB , P Iris , Dual Streaming, Frame rate 30 FPS on 1080p resolution, Smart advanced video Compression, Electronic Shutter Speed Auto / Manual (1/15 ~ 1/32000), Anti-Flicker, Slow Shutter (1/2,1/3,1/5,1/6, 1/7.5,1/10), 3D DNR , Support SD card, Audio Input & Output, Alarm Input & output, Polygon motion detection, Privacy masking, ONVIF, Ethernet port 10/100 Mbps, ,12DC, PoE, Metal body, IP66 & IK 10 protection, Certificate UL, BIS, EN , FCC & RoHS Certification. 3 Years Standard Warranty.
OD322304/2025-2026 Supply, installation, testing and commissioning of 360 deg Indoor Dome IP Camera with 5 Megapixel CMOS digital image sensor providing recording resolution 4 MP Pixel, minimum 15 FPS @ 4 MP, support four independent stream simulaneously, High WDR@60dB. Constant 360 degee recording along with simultaneous multiple angles of view using one sensor, 3D client side dewarping with no blind spots with IP40, Polygon motion detection minimum 8 regions, privasy masking 5 regions, support SD card Upto 4 GB , support multi users minimum 10 users, support onvif profile S. Certificate UL, EN, BIS and RoHs certified.
OD322315/2025-2026 Supply, installation, testing and commissioning of Recording Server with Latest Gen 2x Intel Xeon/AMD 8 Core 64 Bit Processor 2.9 GHz or better base performance, 64 GB of RAM @ 2933 MHz DDR4 ECC or better Server Class Memory, 2x 600 GB 10k rpm hard disk for OS & Applications configured in RAID 1, RAID- 5 configured from DAY 1,latest 8Gb graphic card, 48TB RAID 5 enterprise grade SATA HDD with minimum 40 TB Usable for 30 days storage 1080p, geotagging and compatibility to chromecast devices 4x GbE Network Interface Card or higher bandwidth interfaces.To be supplied with suitable HBA cards for connecting with SAN/Server Farm switch and storage box, Interfaces : D-sub VGA/HDMI/DVI and 4 x USB 3.0 or better. Enterprise SAS/SATA 2.5”/3.5"; Hot Swappable, Certifications/ Regulatory Compliance for hardware – BIS, Operating System: Licensed version of 64 bit Server Edition latest version of Microsoft® Windows.
OD323270/2025-2026 Supply, installation, testing and commissioning of Professional Video Control Operations Management Playback Recording Single Server Video Surveillance 64 bit Software with 72 channel camera licensce with unlimited clients supporting 5000+ Camera models Onvif S supported edge base recording, advance maps, client software, advance event and action manager.
OD323333/2025-2026 Supply, installation, testing and commissioning of Client workstation with Enterprise Windows OS 10 Pro 64 Bit Grade Workstation with Intel i9 10th Generation processor 10980XE@3GHz, 64 GB DDR RAM, NVIDIA Quadro P8000 (8GB GDDR5), 1TB HDD.
OD323334/2025-2026 Supply, installation, testing and commissioning of 24 Port L2 PoE Switch - 10/100/1000 mbps POE 24 port ethernet switch with min 2 no. SFP port complete as required
OD323335/2025-2026 Supply, installation, testing and commissioning of 8 Port L2 PoE Switch - 10/100/1000 mbps POE 8 port ethernet switch complete as required
OD323337/2025-2026 Supply, installation, testing and commissioning of 8 TB Survillance HDD
OD323338/2025-2026 Supply, installation, testing and commissioning of 55" Monitor (as per specifications)
OD323339/2025-2026 Supply, installation, testing and commissioning of 6U Wall mount Rack with Power Distribution Unit, FAN, Mounting Hardware Packet complete as required
OD323341/2025-2026 Supply, installation, testing and commissioning of 24U Rack for Control Room - Networking Enclosure Closed rack with Front Glass door, rear steel door, castors, fans with fan tray, power strips and complete with all accessories as required. (along with Horizontal cable manager and vertical Cable manager, PDU with required 16 Amp Socket)
1.53.1 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
ACCESS CONTROL SYSTEM
OD323484/2025-2026 Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled 2 reader / 2 door controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers
OD323487/2025-2026 Supply, installation, testing and commissioning of Access Control Application Software for 64 Reader Capacity, and up to 1000 Card Holder Capacity, Basic GUI, TA Module with Alarm Module, T+ Module, 1-Nos Client Work Stations,Module for using SQL DB, -MULTI Site Module.
OD323488/2025-2026 Supply, installation, testing and commissioning of work station for access control software
OD323493/2025-2026 Supply, installation, testing and commissioning of UL Listed Smart Card Reader with compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards. Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry-standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight.
OD323494/2025-2026 Supply, testing and commissioning of iClass Smart card
OD323495/2025-2026 Supply, testing and commissioning of Exit Push Button.
OD323501/2025-2026 Supply, testing and commissioning of Glass break.
OD323502/2025-2026 Supply, installation, testing and commissioning of Single Leaf Electro Magnetic Lock of Suitable Capacity (Min 600 lbs).
OD323522/2025-2026 Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity (Min 1200 lbs).
OD323523/2025-2026 Supply and Fixing of ''U'' Bracket with Accessories.
OD323525/2025-2026 Supply, installation, testing and commissioning of 24 port 100/1000 Mbps switch with accessories
OD323528/2025-2026 Supply, installation, testing and commissioning of 12 U rack with 600x 600mm dimension with complete acessories
OD323530/2025-2026 Supply, Fixing and Laying of 8 Core x 0.5 sqmm multi strand, copper, unarmoured Cable (between the every readers & the access controllers).
OD323531/2025-2026 Supply, Fixing and Laying of 3 Core x 1.5 Sq mm, multi strand, copper, unarmoured cable (between the controller and EM Lock/Request to exit button).
AUDIO VISUAL SYSTEM
OD323802/2025-2026 Supply, Installation, testing and commissioning of 55 inch 4K/UHD Professional Display. Brightness: 400 nits or better, Min 2x HDMI, 1x RS232/Ethernet. Should be provided with all wall mounting accessories. [For Small Meeting Rooms, Interview Room]
OD323803/2025-2026 Supply, Installation, testing and commissioning of 55 inch 4K/UHD Professional Display. Brightness: 400 nits or better, Min 1x HDMI, 1x RS232/Ethernet. Should be provided with confidence monitor cart. [For Seminar Halls]
OD323804/2025-2026 Supply, Installation, testing and commissioning of 65 inch 4K/UHD Professional Display. Brightness: 400 nits or better, Min 1x HDMI, 1x RS232/Ethernet. Should be provided with all wall mounting accessories. [For 12/20 seater Meeting Rooms, Board Room]
OD323805/2025-2026 Supply, Installation, testing and commissioning of 5200 lumen projector with lenses, min 1x HDMI, 1x RS232/Ethernet. Should be provided with all accessories and below equipments: a. ceiling mount kit b. 150" motorised screen with LVC control [For 50 Seater Seminar Hall]
OD323808/2025-2026 Supply, Installation, testing and commissioning of 8000 lumens projector with lenses, min 1x HDMI, 1x RS232/Ethernet. Should be provided with all accessories and below equipments: a. ceiling mount kit b. 189" motorised screen with LVC control [For 87 Seater Seminar Hall]
OD323827/2025-2026 Supply, Installation, testing and commissioning of 10000 lumens projector with lenses, min 1x HDMI, 1x RS232/Ethernet. Should be provided with all accessories and below equipments: a. ceiling mount kit b. 250" motorised screen with LVC control [For 196 Seater Seminar Hall]
OD323895/2025-2026 Supplying, installation, testing and commissioning of 23.8” Interactive Touch Monitor for Live annotation with HDMI input, 1920 x 1080p Resolution. USB Interface. VESA Mounting, To be supplied woth complete accessories. [For Seminar Halls]
OD324225/2025-2026 Supplying, installation, testing and commissioning of software VC kit including USB camera, microphone and PC with application for software based video conferencing, to be supplied with complete accessories [For Interview Room]
OD324250/2025-2026 Supplying, installation, testing and commissioning of Full HD PTZ Camera with minimum 20x zoom featuring HDMI output, Including wall mounting accessories [For 50 & 87 Seater Seminar Hall, 20 seater Meeting room and Board Room]
OD324262/2025-2026 Supplying, installation, testing and commissioning of Full HD PTZ Camera with minimum 30x zoom featuring HDMI output, Including wall mounting accessories [For 196 Seater Seminar Hall]
OD324455/2025-2026 Supplying, installation, testing and commissioning of PC with application for software based video conferencing, to be supplied with complete accessories. [For 20 seater Meeting room and Board Room]
OD324467/2025-2026 Supply, Installation, Testing and commissioning of HDMI to USB Scaling Bridge and audio converter. Input: 1xHDMI, Output: 1x USB 2.0, 1x HDMI Loop out. Shall have built in scaling. Audio Input: 1x stereo line level, 1x mono mic/line level, balanced or unbalanced with phantom power, Audio Output: 1x stereo, balanced or unbalanced. Shall be used with Microsoft® /Skype® for Business/Teams, Adobe® Connect™, BlueJeans, Cisco® WebEx®, Zoom, and others. Integrated DSP shall provide 4x2 or better audio routing, including mixing. Built in HDMI Audio De-embedding. Control : 1 female RJ-45 with 10/100/1000Base-T ethernet data rate, Shall meet regulatory compliance:CE, UL, RoHS, WEEE [For 20 seater Meeting room, Board Room and Seminar Halls]
OD324491/2025-2026 Supplying, installation, testing and commissioning of USB switcher with 4 host ports and 4 port hub for peripherals [For 20 seater Meeting room and Board Room]
OD324506/2025-2026 Supplying, installation, testing and commissioning of USB extender set for USB data rates upto 480 Mbps
OD324620/2025-2026 Supplying, installation, testing and commissioning of Video Recorder for recording all kind of meetings including video conference. 02 or more HDMI Input. one or more analog video input. one or more balaced/unbalaced analog audio Input, Minimum two window Picture-in-Picture (PIP). Resolution minimum 1080P@30fps or better. Shall be able to send two different streams simultaneously. Built in stroage of minimum 80GB and external storage of minimum 1TB. RS232/LAN control. [For 20 seater Meeting rooms, Board Room & Seminar Halls]
OD324657/2025-2026 Supplying, installation, testing and commissioning of PIP Processor. Inputs: 3x HDMI, Output: 1x HDMI. Flexibility to allow unrestricted two-window display of standard definition and high resolution digital video sources. Supports PIP, PbP, and option to store multiple layout presets. Seamless transition in switching. Built in Scaling. Control: RS232/Ethernet [For 50 Seater Seminar Hall]
OD324660/2025-2026 Supplying, installation, testing and commissioning of Picture in Picture (PIP) processor supporting minimum 04 HDMI inputs. one or more HDMI output. One or more twisted pair output. Shall be able to show Four HDMI video sources simumtaneously on a single display on HDMI output. All inputs and outputs shall supoort minimum 4K, 60Hz @4:4:4 resolution or higher. Shall provide unrestricted Four-window picture-in-picture (PIP) with programable preset options. Shall feature built in high quality scaling with aspect Ratio Control (Fill and Fillow Mode) with seamless switching. Support ultra wide resolution. Should have EDID managemnet feature and HDCP Compliant. Controls: Front button panel, RS232, Ethernet. Shall meet regulatory compliance: CE, c-UL, UL [For 87 & 196 Seater Seminar Halls]
OD324730/2025-2026 Supplying, installation, testing and commissioning of Sleek rectangular Cable access enclosure for AV connectivity and 2nos. 6A switch & power socket, 1no. HDMI, 1no. USB-C, 2no. LAN, etc
OD324793/2025-2026 Supply, installation, testing and commissioning of wireless content sharing solution to support content from Windows and Apple OS computers as well as Apple and Android smartphones, and tablets. 1x HDMI 2.0 input supporting upto 4K/60, 1x HDMI 2.0 output with embedded audio supporting upto 4K/60. CEC/RS-232 control for display. Dual NIC for isolated networks and H.264 decoding support. Shall meet regulatory compliance: CE, c-UL, UL
OD324825/2025-2026 Supply, Installation, testing and commissioning of digital matrix switcher. Should have Inputs: 4x HDMI, Outputs: 2x HDMI, Backplane Bandwidth: min 18 Gbps or better. Resolution Support: 4K, 60 Hz, 4:4:4. Should have built-in audio de-embedding. Control option: RS232/Ethernet [For 12 Seater Meeting Rooms]
OD324839/2025-2026 Supplying, installation, testing and commissioning of two input HDMI switcher with HDMI output and twisted pair/HDBT output with video, audio and RS-232 control extension [For Seminar Halls]
OD324843/2025-2026 Supplying, installation, testing and commissioning of twisted pair transmitter having HDMI, Audio & Control. Inputs: 1xHDMI, 1xAnalog Audio, 1xControls (RS 232/IR), Outputs: 1 x Twisted pair/ HDbaseT on RJ 45, 4K resolution, transmission distance: Minimum 70m. HDCP Compliant: Should be HDCP 2.3 Compliant, EDID: Should have inbuilt EDID management, Shall meet regulatory compliance: CE, c-UL, UL [For Cable Cubbies & PTZ Cameras]
OD324860/2025-2026 Supplying, installation, testing and commissioning of twisted pair receiver having HDMI, Audio & Control. Inputs: 1 x Twisted pair/ HDbaseT on RJ 45, Outputs: 1xHDMI, 1xAnalog Audio, 1xControls (RS 232/IR), 4K resolution, transmission distance: Minimum 70m. HDCP Compliant: Should be HDCP 2.3 Compliant, EDID: Should have inbuilt EDID management, Shall meet regulatory compliance: CE, c-UL, UL [For Cable Cubbies, displays & PTZ Camera]
OD324913/2025-2026 Supplying, installation, testing and commissioning of All in one Scaling Presentation Matrix Switcher with twisted pair Extension, 4K resolution, Scaling on twisted pair output or provided with Scaing receivers. Amplifier and Control Processor, 2x STP input, 6x HDMI input, 4 or more STP output, 2 or more HDMI output, Built -in or separate AV controller: 3x RS-232 port, 2x IR/serial, 4x Relay, 1x Etherent, SDRAM: 4.5 GB, Flash: 8 GB. Shall meet regulatory compliance: CE, c-UL, UL [For 20 Seater meeting & Board Room]
OD324919/2025-2026 Supplying, installation, testing and commissioning of All in one Scaling Presentation Matrix Switcher with twisted pair Extension, 4K resolution, Scaling on twisted pair output or provided with Scaing receivers. Amplifier and Control Processor, 2x STP input, 6x HDMI input, 4 or more STP output, 2 or more HDMI output, Built -in or separate AV controller: 3x RS-232 port, 2x IR/serial, 4x Relay, 1x Etherent, SDRAM: 4.5 GB, Flash: 8 GB. Shall meet regulatory compliance: CE, c-UL, UL [For Seminar Halls]
OD324920/2025-2026 Supply, Installation, testing and commissioning of Elegantly designed Podium, built in AV Connectivity. Should have provision to mount Cable Access Enclosure and accomodate minimum 24" touch monitor on a VESA mounting. To be supplied with PC and complete accesories including Power Distribution Unit and Cable manager and castors. [For Seminar Halls]
OD324923/2025-2026 Supplying, installation, testing and commissioning of Wireless Lavalier Microphone Transmitter & Receiver Set [For 87 & 196 Seater Seminar Halls]
OD324924/2025-2026 Supplying, installation, testing and commissioning of Wireless Handheld Microphone Transmitter & Receiver Set [For 87 & 196 Seater Seminar Halls]
OD324925/2025-2026 Supply of Charging set with USB charger and 2 rechargeable battery packs for handheld and bodypack transmitter. It should charge 100% battery power in max. 3 hours charging time. Maximum operating time of 12 hours. Stackable and charging is through USB-C. [For 87 & 196 Seater Seminar Halls]
OD324926/2025-2026 Supply of Digital Wireless bodypack transmitter with with 3.5 mm jack connector, condenser omnidirectional clip-on microphone, Sensitivity: 17 mV/Pa, Sound pressure level: 130 dB SPL, Frequency response: 20Hz - 20KHz, System latency: 1.9 ms, Dynamic range: 130 dB, 10mW RF power with up to 100m/328ft working range, Programmable mute switch along with battery backup of 12 hours. [For 50 Seater Seminar Hall]
OD324928/2025-2026 Supply of Digital Wireless handheld transmitter with dynamic cardioid microphone capsule, Sensitivity: 2.1 mV/Pa, Sound pressure level: 154 dB SPL, Frequency response: 20Hz - 20KHz, System latency: 1.9 ms, Dynamic range: 130 dB, 10mW RF power with up to 100m/328ft working range, Programmable mute switch, persistent E-Ink display for always on information along with battery backup of 12 hours. [For 50 Seater Seminar Hall]
OD324929/2025-2026 Supply of Network enabled 2 bay charger for handheld and Bodypack transmitter, it can be cascaded upto 5 chargers with the help of external power supply unit, 3 hrs charging team, RJ-45, IEEE 802.3 network socket, It shall support the Media Control Protocol to provide for remote control and status monitoring via the centralized management software. [For 50 Seater Seminar Hall]
OD324933/2025-2026 Supply of Wireless UHF gooseneck microphone with a programmable mute switch for muting or unmuting the audio signal, 40 cm cardioid condenser microphone, Frequency response: 50 Hz - 20 kHz, Maximum sound pressure level: 130 dB SPL, Dynamic range: 130 dB, System latency: 1.9 ms along with Lithium-Ion rechargeable accupack with a operating time of 11 hours and shall support wireless charging as well as charging via USB. [For 50 Seater Seminar Hall and 12 seater Meeting rooms]
OD324936/2025-2026 Supply of wireless charger which should support capable of wirelessly charging up to two microphones, should support 5 hours or less for full charging. [For 50 Seater Seminar Hall and 12 seater Meeting rooms]
OD324968/2025-2026 Supply of Four-channel digital Dante enabled receiver, should support automatic frequency setup function, intermodulation free operation with spectrum scan functionality to establish an equidistant frequency grid for more than 250 channels. Frequency response: 20Hz - 20KHz, System latency: 1.9 ms, Dynamic range: 130 dB, AES 256 encryption, Ethernet ports (RJ-45) for remote network-based monitoring, headphone output along with OLED display to showing the current frequency, channel number, metering of RF level, metering of AF level, lock status, muting function, antenna switching diversity, app connection, gain, audio output level, menu, and battery status for each of the transmitters, Integrated antenna splitter with antenna power and loop through to daisy chain up to 16 channels, Four network ports for flexible network configurations - each port can be assigend as: Control, Control + Dante® Prim, Control + Dante® Sec, Dante® Prim, Dante® Sec, can be controlled through smart Assist App which can monitor the system remotely. [For 50 Seater Seminar Hall and 12 seater Meeting rooms]
OD324969/2025-2026 Supply of Two-channel digital half-rack Dante enabled receiver, should support automatic frequency setup function, intermodulation free operation with spectrum scan functionality to establish an equidistant frequency grid for more than 250 channels. Frequency response: 20Hz - 20KHz, System latency: 1.9 ms, Dynamic range: 130 dB, AES 256 encryption, Ethernet ports (RJ-45) for remote network-based monitoring, headphone output along with OLED display to showing the current frequency, channel number, metering of RF level, metering of AF level, lock status, muting function, antenna switching diversity, app connection, gain, audio output level, menu, and battery status for each of the transmitters, can be controlled through smart Assist App which can monitor the system remotely.
OD324970/2025-2026 Supply, Installation, testing and commissioning of digital signal processor with Dante, AEC & USB for audio with 12 mono analog inputs and 8 mono analog line level outputs for audio signal routing and management. DSP Should feature phantom power on min 8 or more inputs, digital audio expansion port. Automixer function with eight groups, 64-bit floating point DSP engine, USB audio interface. Dante support. Shall be able to receive min 48 Dante channel, and shall be able to transmit min 24 channle over Dante. Supports AEC on min 12 channel. Safety compliances: CE, c-UL, and UL.
OD324972/2025-2026 Supply, Installation, testing and commissioning of dual channel power amplifier with 100 watts rms per channel into a 70/100Volts output. Audio input: 2 channel balanced/ unbalanced. Audio output: 2 channels, 70/100 Volts output. THD + Noise: 0.1% or better. S/N Ratio: 100 dB or better. [For 12 & 20 Seater Meeting and Board Rooms]
OD324973/2025-2026 Supply, Installation, testing and commissioning of full-range ceiling speakers with 70/100 V Transformer, 32 watts continuous program, 165° conical dispersion, including all mounting accessories. [For 12 & 20 Seater Meeting and Board Rooms]
OD324994/2025-2026 Supply, installation, testing and commissioning of Digital Delegate Discussion unit with removable microphone (30, 40, 50 or 70 cm) - Microphone connector - Microphone button and volume control button - Built-in loudspeaker - Headphone connector - Cable of 2 meters included Device shall be provided with neccessary cables and connectors [For 20 Seater Meeting Room & Board Room]
OD325003/2025-2026 Supply, installation, testing and commissioning of Digital Chairperson Discussion unit with removable microphone (30, 40, 50 or 70 cm) - Microphone connector - Microphone button, priority, next-in-line and volume control button - Built-in loudspeaker - Headphone connector - Cable of 2 meters included Device shall be provided with neccessary cables and connectors [For 20 Seater Meeting Room & Board Room]
OD325019/2025-2026 Supply , installation , testing and commissioning of GSM immune gooseneck microphone of 40 cm with screwlock. Bi-color led ring indication (red / green). Windscreen included. (to be used with delegate/chairman discussion units) [For 20 Seater Meeting Room & Board Room]
OD325022/2025-2026 Supply, installation, testing and commissioning of Digital control unit with integrated recording capability - 4 digital RJ 45 ports - Branch or loop connection (redundancy) - LAN connection for web server, camera control protocol or AES67 communication - 2 x USB-C for audio connection with UC or multi-channel recording - 2 x XLR OUT, 2 x XLR IN - 3,5mm line in and out - Plug and Play - Eco Power Safe mode - Power connector with locking - External power supply included Shall be provided with neccessary cables and connectors [For 20 Seater Meeting Room & Board Room]
OD325024/2025-2026 Supply of Active Antenna Splitter with 2 x 1:4 or 1 x 1:8 active connections, which work on 56 MHz Bandwidth and allow for up to 90 channels, Supports Mobile App streamlines setup and operation and eliminates complicated menus, Frequency range: 470 – 694 MHz, along with Automated setup creates reliable connections with minimal time and effort. [For all Seminar Halls]
OD325027/2025-2026 3 x 4:1 Antenna Combiner, compatible with all analog and digital wireless stationary receivers operating in the supported frequency range of 470 to 798 MHz. [For 50 Seater Seminar Hall]
OD325034/2025-2026 Supply of Passive directional antenna, Built-in ⅝" and ⅜" threads allow for easy mic stand mounting, Frequency range 470 – 1075 MHz, Apex angle (-3 dB) approx. 100°, Front-to-back ratio > 14 dB, Gain typ. 5 dBi and Impedance 50 Ω. [For all Seminar Halls]
OD325035/2025-2026 Supply of Mounting plate for antenna with 3/8" thread, Antenna can be attached directly or via swivel joint. [For all Seminar Halls]
OD325036/2025-2026 Supply of Swivel joint for aligning radiators for splitters. [For all Seminar Halls]
OD325042/2025-2026 Supply of Swivel joint for aligning radiators for Booster. [For all Seminar Halls]
OD325043/2025-2026 Supply of Antenna booster which work on 56 MHz Bandwidth and allow for up to 90 channels, Supports Mobile App streamlines setup and operation and eliminates complicated menus, Frequency range: 470 – 694 MHz, along with Automated setup creates reliable connections with minimal time and effort. [For all Seminar Halls]
OD325049/2025-2026 Supply, Installation, testing and commissioning of dual channel power amplifier with 600 watt per channel [For 50 & 196 Seater Seminar Halls]
OD325050/2025-2026 Supply, Installation, testing and commissioning of 2 channel amp with 1000 watt per channel [For 196 Seater Seminar Hall]
OD325056/2025-2026 Supply, Installation, testing and commissioning of 4 channel amp with 300 watt per channel [For 87 Seater Seminar Hall]
OD325057/2025-2026 Supply, Installation, testing and commissioning of FOH speakers as per specification, including all mounting accessories. [For 50 & amp; 87 Seater Seminar Halls]
OD325066/2025-2026 Supply, Installation, testing and commissioning of FOH speakers as per specification, including coupling bracket and all mounting accessories. [For 196 Seater Seminar Hall]
OD325068/2025-2026 Supply, Installation, testing and commissioning of 60 W ceiling speakers, including all mounting accessories. [For 87 & amp; 196 Seater Seminar Hall]
OD325093/2025-2026 Supply, Installation, testing and commissioning of AV controller with atleast 1x Bidirectional RS-232, 1x IR/serial, 2x digital I/O. Should have built-in 1 GB RAM and 8 GB Flash memory. Should meet CE, UL regulatory compliance [For 12 seater Meeting room]
OD325095/2025-2026 Supply, Installation, testing and commissioning of Fully Programmable 10" capacitive touchscreen interface for switching and control of AV equipment. TFT Active matrix Color LCD display, Resolution 1280x800 or higher, Color depth : 24 bit, 16.7 million colors or higher, Brightness: 400 nits (cd/m2) or higher, Viewing angle: ±80° horizontal, ±80° vertical or more, Capacitive Touch screen. Memory: 4GB Flash, SD RAM: 2 GB. 10/100/1000Base-T female RJ-45 connector. Shall be supplied with Powere supply or POE Injector. Shall meet regulatory compliances: CE, c-UL, UL
OD325096/2025-2026 Supply, Installation, testing and commissioning of 8 Port Full Duplex 10/100/1000Mbps Auto-Negotiation RJ45 network switch, Fanless architecture, Standards and Protocols: IEEE 802.3 / 802.3u / 802.3ab/ 802.3x /802.1p to be supplied along with Built-in or external power supply.
OD325097/2025-2026 Supply, Installation, testing and commissioning of 16 Port Full Duplex 10/100/1000Mbps Auto-Negotiation RJ45 network switch, Fanless architecture, Standards and Protocols: IEEE 802.3 / 802.3u / 802.3ab/ 802.3x /802.1p to be supplied along with Built-in or external power supply.
OD325098/2025-2026 Supply, Installation, testing and commissioning of 6' (1.8 m) HDMI male(M) to HDMI Male (M) Cable with 28 AWG copper wire construction, resolution support of 4K/UHD @ 60 Hz, 4:4:4 or better, Gold plated connectors
OD325099/2025-2026 Supply, Installation, testing and commissioning of USB-C male to HDMI female adapter cable, 6" (15 cm) in length, supporting resolutions upto 4K
OD325100/2025-2026 Supply, Installation, testing and commissioning of 35' (10.6 m) HDMI male(M) to HDMI Male (M) fiber based cable, resolution support of 4K/UHD @ 60 Hz, 4:4:4 or better, Gold plated connectors
OD325101/2025-2026 Supply, Installation, testing and commissioning of 32 U Equipment Rack, Locakable front glass door, cooling facility, internal wiring, front glass door, heat dessipation fans, movement wheels, power distribution units & equipment shelves as required, fully welded construction for strength. Extra-wide rackrail for cable pass-throughs to facilitate front-to-rear cabling
OD325102/2025-2026 Supply, Installation, testing and commissioning of 12 U Equipment Rack, Locakable front glass door, cooling facility, internal wiring, front glass door, heat dessipation fans, movement wheels, power distribution units & equipment shelves as required, fully welded construction for strength. Extra-wide rackrail for cable pass-throughs to facilitate front-to-rear cabling
OD325103/2025-2026 Supplying, installing, testing and commissioning of Enterprise-class Wireless Access Point with IEEE 802.11ac dual-band radios and embedded antenna
BUILDING MANAGEMENT SYSTEM
OD325129/2025-2026 BMS SERVER Supply, Installation, Testing and Commissioning of BMS Server shall comprise of the following minimum hardware: Intel i7 min 3.2 GHz processor, 8 GB of RAM or higher, 21” LCD Color Display (1280 x 1024) , 12 function-126 key keyboards (English) Mouse pointing device; 1TB HDD for OS & BMS Software, and BMS Database. Graphics Card – NVS 315 or higher version,1024MB DDR3or better; NIC (network interface card) for Ethernet Networking compatible with TCP/IP network protocols (UTP/Fiber); Complete with with AntiVirus,MS Windows Client Software and operating license.
OD325265/2025-2026 Supply, Installation, Testing and Commissioning of 16 port Network Switch unmanaged
OD325266/2025-2026 Building Operating System: Software- Supply, Installation, Testing and Commissioning of BTL LIsted, Building Automation Server software, with 5000 I/O point, unlimited concurrent users and it shall utilize the latest JAVA technologies. The protection of software database should be as per the 21 CFR part11 guidelines to ensure that no data is lost/Tampered. Teh software should have trends, logs, alarms for every point that is connected to the software. The software should be able to integrate with equipments that communicate on Modbus/IP, BACNET/IP, Lonworks/IP, SNMP, KNX and M-Bus/IP. The cost for this integration (using addtional hardware/ software drivers) needs to be considered in the software. The system should have following features: - System Integrations - Custom Dashboards - Graphical User Interfaces - Profiles and User Rights - Alarm Handling - Trends and Event Logs - Monitoring and Reporting - JS based Scripting Interface Web user license - 10 Concurrent/ Simultaneous users Software Engineering and Commissioning Dongle of the manufacturer. (Bidders need to confirm that the Engineering and Commissioning Dongle of the manufacturer will be handed over to customer at the time of site handing over) Email Alerts of Alarms
OD329471/2025-2026 THIRD PARTY SYSTEM INTEGRATION Supply, Installation, Testing and Commissioning of Gateway and Open Protocol Software/ Hardware compatible to industrial standard protocols like Modbus RTU, Modbus over Ethernet, BACNet-MSTP, BACNet-IP, LON, M-Bus for the following third party system coming on these universal protocols. (Refer IO Summary for number of devices and datapoints, equal number of converters to be considered per system). The unit shall be supplied with wall mounted enclosures including all wiring and accessories complete. The hardware shall be mounted in the panel enclosure similar to that of DDC Panels or can be accomodated in the DDC Panel design itself. Not more than 30 device can be connected. Third party equipments should be compatible with either RS485 trunk for Modbus / BACnet over IP Communication protocol. (Supply price included with DDC panel, only installation cost included) Integrator for chiller Plant: 1 No, Integrator for AHU & CSU: 2 Nos, Integrator for PAC/Data Centre Cooling: 1 No,Integrator for Pressurization Unit: 1 No. Integrator for VAV boxes: 3 Nos, ntegrator for Energy meters: 3 Nos ,Integrator for UPS room : 1 No, Integrator for TFA: 1 No, Integrator for FCU: 1 No,Integrator for Water Leakage Detection: 1 No,Integrator for Fire Alarm System: 1 No.
OD327054/2025-2026 Supply, Installation, Testing and Commissioning of Immersion Temperature Sensor with Thermowell
OD327078/2025-2026 Supply, Installation, Testing and Commissioning of Outdoor Humidity & Temperature Transmitter
OD327080/2025-2026 Supply, Installation, Testing and Commissioning of Differential Pressure Switch, Liquid
OD327103/2025-2026 Supply, Installation, Testing and Commissioning of Liquid Flow Switch
OD327110/2025-2026 Supply, Installation, Testing and Commissioning of H2 Specific Sensor ( Battery Room)
OD327123/2025-2026 Supply, Installation, Testing and Commissioning of Modulating Modbus Thermostat
OD327141/2025-2026 Supply, Installation, Testing and Commissioning of CO2 Sensor Wall Mount
OD327663/2025-2026 Supply and laying of 2 Core 1.0 SQ. MM, unarmoured ATC conductor multistranded, PVC FRLS, Unscreened signal cable. ( For DI & DO Points)
OD327705/2025-2026 Supply and laying of 4 Core 1.0 SQ. MM, unarmoured ATC conductor multistranded, PVC FRLS Unscreened signal cable. ( For DI & DO Points)
OD327713/2025-2026 Supply and laying of 2 Core 1.0 SQ. MM, unarmoured ATC conductor multistranded, PVC FRLS, screened signal cable. ( For AI & AO Points)
OD327728/2025-2026 Supply and laying of 4 Core 1.0 SQ. MM, unarmoured ATC conductor multistranded, PVC FRLS, screened signal cable. (For AI & AO Points - For Duct Static Pressure, H2 & RH Sensors and Valve Control)
OD327748/2025-2026 Supply and laying of 2 Core 1.0 SQ. MM, unarmoured ATC conductor multistranded, screened, shielded, PVC FRLS communication cable.
OD327863/2025-2026 Supplying and drawing of UTP CAT 6A LAN Cable LSZH in the existing surface/ recessed Steel/ PVC conduit as required.
OD327910/2025-2026 Supply and installation of MS POWDER COATED (GREY COLOUR) Raceways of 2mm thickness with cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two coat of enamel paint over a coat of primer. Required junction boxes at specified intervals shall be considered 500 x 50 x 2 mm thick
OD327938/2025-2026 Supply and installation of MS POWDER COATED (GREY COLOUR) Raceways of 2mm thickness with cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two coat of enamel paint over a coat of primer. Required junction boxes at specified intervals shall be considered 450 x 50 x 2 mm thick
OD328032/2025-2026Supply and installation of MS POWDER COATED (GREY COLOUR) Raceways of 2mm thickness with cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two coat of enamel paint over a coat of primer. Required junction boxes at specified intervals shall be considered 300 x 50 x 2 mm thick
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Volume1TDLIBRARYBLOCK.pdf
Tender Documents • 2.03 MB
Volume2TDLIBRARYBLOCK.pdf
Tender Documents • 1.51 MB
TenderDrawings.pdf
Tender Documents • 12.36 MB
BOQ_1426404.xls
BOQ • 0.42 MB
DATECORRIGENDUMELVrevised2.pdf
PDF • 0.59 MB
DATECORRIGENDUMELV2.pdf
PDF • 0.59 MB
Datecorrigendum2.pdf
PDF • 0.59 MB
TechnicalCorrigendum2.pdf
PDF • 3.07 MB
DATECORRIGENDUMELV.pdf
PDF • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .