Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC As the quoted amount is well within the estimated and justified cost. | |
| 2 | L2₹18.1 L+₹32,407 (1.83%)Rejected-Finance H NO 54 8 DARMYANA MUHALLA DISTT MANDI 1750051 | MANDI | MANDI | HIMACHAL PRADESH | 175005 | L2 | Rejected-Finance Quoted rates are highest |
Tender Value
₹18.1 L
EMD Value
₹36,136
Closing Date
27 Jun 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer IIT Mandi HP
Superintending Engineer IIT Mandi HP-175075
Construction of office cabins for the Dean Resource Generation and Alumni Relations at 3rd floor in A-09 block at North Campus of IIT Mandi H.P.
2022_IITMD_695369_1
IIT Mandi (CW)/SE-1275/22-23/2150-52 dt. 16-06-22
Open Tender
Civil Works
Item Rate
45 days
North Campus of IIT Mandi
please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹36,136
8 Aug 2022
16 Jun 2022
28 Jun 2022
16 Jun 2022
27 Jun 2022
16 Jun 2022
16 Jun 2022 - 24 Jun 2022
Amount
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material in all lead and lift.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24mm of all Tsections shall be pre-painted with polyster baked paint,for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer. as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 1.15 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801-1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately Cement Fiber Board 8 mm thick as per IS 14862:2000 of type B (High pressure Steam Cured) as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm as per entire satisfaction and direction of Engineer -in-charge
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm as per entire satisfaction and direction of Engineer -in-charge
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3x2.5 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit/Wall Trunking/Casing as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3x4 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit/Wall Trunking/Casing as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 32 sq mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required of make: Polyfit, Poly Champ, Diplast as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 15/16 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 pin 5/6 A socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 pin 15/16 A socket outlet modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Module Modular base & cover plate on existing modular metal/PVC boxes etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 Module Modular base & cover plate on existing modular metal/PVC boxes etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 way (4 + 18), Double door, Double door, Double door TPN DB horizontal type prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(excluding MCB/RCCB) of Make :- Havells , L&T, Legrand as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required of Make :- Havells , L&T, Legrand as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 Amp rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required of make Havells , L&T, Schinder as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 35 Sq. mm size on Cable Tray (Clamped with 1 mm thick saddle) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supply, installation, balancing and commissioning of Thickness 0.63 mm sheet fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 Modue PVC box to be fixed in the existing Wall Trunking as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Module PVC box in open surface/wall as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 Module PVC box in open surface/wall as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, Installation, testing and commissioning of pre-wired, Square Recess Down Lighter(595x595 mm) of Wattage 36 W (6500K) directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Dismantling of ceiling fan including cleaning of surface with Cotton Cloth and replacing the damaged rubber reel, nuts and bolts with washers and safety pins refixing the same as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Dismantling and Cleaning of Recesed/Surface Down Lighter with Cotton Cloth with full precaution taken as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and installation of GI fan rod of length up to 2.5 m per fan including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 25 mm size of medium class PVC Casing-Capping along with accessories in surface as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying, Installation, testing and commissioning of wall fan (400 mm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 25 A, MCB DBOXXMCB procted Socket Modular (With Sheet Steel Enclosure) plug top, on surface or in recess, for the socket out let and complete with connections, testing and commissioning etc. as required of Make :- Havells , L&T, Legrand as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 amps rating, four pole, 415 volts,MCB in the existing TPN Box complete with connections, testing and commissioning etc. as required as per entire of Make:- Havells, Schneider, L&T satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 4 Core x 6 Sq. mm of 1.1 KV Copper conductor XLPE Insulated,PVC extruded inner-sheathed, round wired , overall PVC outer-sheathed (as per IS 7098 Part 1) with latest amendments as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and copper lugs for 4 X 6 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Mansih Kapoor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .