Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC Being lowest bidder. | |
| 2 | L2₹13.7 L+₹47,635 (3.59%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder. |
Tender Value
₹16.2 L
EMD Value
₹32,320
Closing Date
2 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU
GE/AFJ-32/2023-24CONST OF POL STORE AND HARDSTANDING IN SURROUNDING AREAS AT RAJOURI UNDER GE (AF) JAMMU
2023_MES_616290_1
CA NO GE/AFJ-32/2023-24
Open Tender
Civil Works
Item Rate
270 days
RAJOURI AND JAMMU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) JAMMU
₹32,320
Yes
6 Feb 2024
29 Aug 2023
4 Oct 2023
29 Aug 2023
2 Oct 2023
12 Sept 2023
Amount
SCHEDULE 'A' PART-I (SITE CLEARANCE AND COMMON NATURE ITEMS WORK)
Excavating over areas, n exc 1.5m deep & getting out in hard / dense soil complete all as specified and directed. .
Excavating over areas, exc 1.5m but n exc 3.0m deep & getting out in hard / dense soil complete all as specified and directed. .
Excavating over areas, exc 3.0m but n exc 4.5m deep & getting out in hard / dense soil complete all as specified and directed. .
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and as directed.
Removal of excavated material as soils not exceeding 50m and at a level not exceeding 1.5m above the starting point and depositing complete all as specified and directed. .
Surface dressing n exc 15 cm deep in any type of soil including removing and cutting all type of bushes, wild vegetation, saplings and removing all roots from underground complete all as specified and directed. .
M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. .
Reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer -in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft beams, sides and soffits, (if any) of foundation and plinth beams, and similar work vertical or to better (Rough finished surface of concrete) surfaces complete all as specified and directed by Engineer -in-charge.
S&F mild steel bars (TMT) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for sand cushioning/covering for under ground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed.
SCHEDULE 'A' PART-II (POL STORE WORK)
Excavation in trenches n.exc 1.5m wide and n exc 1.5m depth for foundation etc n exc 10 Sqm on plan and n exc 1.5 m depth and getting out in hard/dense soil complete all as specified and directed. .
RCC M-25 (design mix)nusing 20 mm graded agg in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer -in-charge.
M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer -in-charge.
M & L RCC 1:2:4 type B-1 as in lintel and lintel band up to 1.5 m clear span including necessary formwork complete all as specified and directed by Engineer -in-charge.
M&L Formwwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete, for square, rectangular or polygonal surfaces complete all as specified and directed by Engineer -in-charge.
M & L Form work to sides of soffits of floor or roof beams, beam haunching, girders, bressummers lintels, cantilevers, shelves including sup-ports, overhang complete all as specified and directed by Engineer -in-charge.
M & L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 20 mm thick (horizontal or sloping) complete all as specified and directed by Engineer -in-charge.
S&F mild steel bars (TMT) 6-8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F portions framed & hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings;holdfast framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 as per directed by Engr-in Charge.
S&F Mild steel, plain black sheet 1.00mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with & including a minimum of 6 bolts & nuts, four on bolt plate & two on staple plate complete all as specified and as directed.
S & F Steel ventilator with top hung , shutter including hinges, steel peg stay, complete all as specified and as directed.
S & F 4 mm thick sheet glass , ordinary quality and glazing with oil putty or wooden n. exc 0.5sq.m in each pane complete all as specified and as directed.
Supply and Fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed with wooden beads of 2nd class hardwood/MS hollow square tube to wooden doors/windows complete all as specified and as directed.
M & L brick work with sub class B bricks straight or curved on plan exc 6 m built in CM 1:4 all as specified and as directed.
M&L rendering 5 mm thick in CM 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and smooth finish without using extra cement complete all as specified.
Rendering 10 mm thick in cement mortar 1:4, on brick or concrete surfaces complete all as specified.
M & L hardcore of broken stones or boulders of gauge n exc .63 mm , deposited , spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface
M & L 100 mm thick PCC in sub base type D 2 1:4:8 using 40 mm crushed stone graded agg complete all as specified and as directed.
M & L 100 mm thick PCC as in flooring type B 2 1:2:4 using 40 mm crushed stone graded agg complete laid in alternate panels incl all necessary form work and floating with surface vibrator all as specified and as directed.
Sand filling under floors conforming to zone III for dumping of FOL in sheds complete all as specified and as directed.
M & L 75 mm thick cement concrete type C-2, 1:3:6 (using 40 mmcrushed stone graded agg ) in plinth protection all as specified and directed
Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Preparation of new plastered surfaces and applying two coats of colour wash on wall complete all as specified and directed.
M & L two coats of cement base paint on newly plastered surface of wall complete all as specified.
Painting two coats with synthetic enamelled paint on new steel or iron surfaces of any description exceeding 10cm width/girth including preparation of surfaces complete all as specified.
SCHEDULE 'A' PART-III (RETAINING WALL WORK)
Excavating over areas, n exc 1.5m deep & getting out in soft / disintegrated rock complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
Formwork to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better Fair finished surfaces of concrete flat complete all as specified and directed.
Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls as in weep holes complete all as specified and directed.
Removing excavated soil exc. 50m but n exc 100m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
SCHEDULE 'A' PART-IV (LIGHTENING PROTECTION AND FIRE ALARM WORK)
S&F single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed.
S&F aluminium strip 25 mm X 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Test point terminal block made out of gun metel or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25 mm long hex head screw complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead 32x6 mm galvanised MS strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.
Cement concrete in mass concrete type C1, 1:3:6 (20 mm graded aggregate) for errection of poles above ground level and coping etc. Rendering 10mm thick on fair faces of concrete surfaces with cement plaster 1:4 complete all as spd and directed.
S & F GI tubes medium grade of dia 32mm with all fitting and fixed with Air termination rod pipes by means of double clamps on top incl duly painted with synthetic enamel alluminium paint over a coat of red oxide primer all as spd and indicated and of length not less than 1.5 meter.
Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360
Detectors Complying with and type certified to EN - 45 Addressable type heat detector with base with rate of rise cum fixed temperature as per IS: 11360
Fire alarm control panel complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector
Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +
Addressable control module
Addressable monitor module
Addressable manual call point resettable type
Addressable sounder
Supply and laying copper conductor armoured cable 1.5sqm ,2 core for complete fire alarm system between outside and inside different rooms fixed in the wall/celling in concealed and including 20mm dia ERW steel conduits ,heavy grade including MS junction boxes all fitting and fixture including all material required for laying/fixing complete all as specified and directed.
SCHEDULE 'A' PART-V INTERNAL ELECTRIFICATION WORK)
Supply and fix flame proof weather proof batten suitable for single twin T8 tube of 16/20 watt IP 65 protected including LED tube rod Make - Crompton/Sudhir/Havells
Supply and fix flame proof exhaust fan SP 230V, 380mm sweep complete with louvers including all connected accessories all as directed and specified.
Supply and fix flame proof distribution box SPN4 way in cast aluminium alloy LM -6 contruction with following incoming bus bar weather proof in cast aluminium LM-6 enclosure, opened by externally spring type knobs, complete with M-25 cable entry to suit incoming cable and 6 Nos M-20 cable entries for out going cables from bottom, suitable for fixing on wall etc duly epoxy powder coated with flame proof flexible metallic conduit upto 01 mtr length including 01 No SPN MCB 1 Amps and 01 Nos MCB SP upto 10 Amps as outgoing duly tested and certifed by CMRI Dhanbad.
4. M&L for point wiring using approved colour coading as per IS with zerohologen flame retardent (HFFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm(nonmial area) single core insulated and unsheathed stranded cable 1100 volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked and unsheathed copper conductor 1.5 sqmm nominal area as earth wire as earth continuity conductor complete all as specified and directed by Engineer in- Charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
M&L for point wiring using approved colour coading as per IS with zerohologen flame retardent (HFFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm(nonmial area) single core insulated and unsheathed stranded cable 1100 volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked and unsheathed copper conductor 1.5 sqmm nominal area as earth wire as earth continuity conductor complete all as specified and directed by Engineer in- Charge.
Supply, Laying, connecting including taking out,testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade Cross sectional area 10 Sqmm 2 core, laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as directed by Engr-in-Charge.(excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately) of following sizes :- Make-CCI/ FINOLEX/Universal Cables/RPG/KEI Indusries Pvt.Ltd
Excavation in trenches not exceeding 1.50m wide and n exc 1.5m in depth for laying of cable etc, and getting out in soft/loose soil including taking out unserviceable brick protections etc complete all as specified and as directed.
M & L for bricks sub class 'B' (locally available best quality) laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Supply, laying or fixing 40mm bore galvanised iron tubing, light grade with all fittings for passing of cables fixed to pole/wall/laid under floor including all fixing accessories complete all as specified and as directed.
SCHEDULE 'A' PART-VII (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .