| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹18.9 L+₹72,631.04 (3.99%)Rejected-AOC 106 AGARWAL AND COMPANY PROFESSOR COLONY OPP OF WALL FORT CITY RING ROAD NO 01 RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹19.1 L+₹90,230.13 (4.95%)Rejected-AOC 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L3 | Rejected-AOC Not accepted since higher quoted rate | |
| 4 | L4₹19.2 L+₹94,977.57 (5.21%)Rejected-AOC | L4 | Rejected-AOC Not accepted since higher quoted rate | |
| 5 | L5₹19.7 L+₹1.4 L (7.96%)Rejected-AOC | L5 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
₹16.6 L
EMD Value
₹33,100
Closing Date
4 May 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIRS TO ROOF TREATMENT IN BLDG NO. P 08 FENCING AND PROVN OF FURNITURE SHOP AT MIL STN GANDHINAGAR
2020_MES_336744_1
GE(A)/GNR/TOKEN/73 of 2019-20
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹33,100
Yes
18 Sept 2020
30 Mar 2020
6 May 2020
30 Mar 2020
4 May 2020
12 Apr 2020
30 Mar 2020 - 11 Apr 2020
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole, laying of cables etc in soft/loose soil and getting out all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Supply and laying sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
Removing excavated material (soil), not exc 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate in foundation, filling post holes and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges, coving, coved fillets of radious 75mm provided at junctions of roof and parapet/ vertical surfaces and like complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in chajja etc complete all as specified and directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in roof beam, cantilevers etc complete all as specified and directed.
M&L for cutting uneven surfaces of concrete & cutting reinforcement from drops of fins & facias (thickness not exceeding 50mm) using necessary scaffolding and making good the disturbed portion with 10mm thick rendering in CM 1:3 finished even and smooth without using extra cement etc. complete all as specifeid and directed.
Removing existing water proofing /black top treatment except concrete padding ruighing of concrete surface cleaning and washing down the surface with water and removing debrish/rubbish material to a distance exc. 1.5 Km but not exc. 5.0 Km out side Md land complete all as specified and directed.
M&L for form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and simillar works not exceeding 20cm thick and rough finished surfaces of concrete all as specified and directed.
M&L for form work to chullah hoods, chajjas , troughs and simollar items including edges and rough finished surfaces of concrete all as specified and directed.
M&L for form work to sides and soffit of floor or roof beams, beams haunchingss, girders, brussummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc and rough finished surfaces of concrete all as specified and directed.
M&L for screed bed 15mm thick on fair faces of concrete surface in cement mortar (1:3) mixed with using water proofing compound by weight of cement as per manufacturer instructions, finished even and smooth without using extra cement for laying APP membrane at non -accessible roof (mumty) complete all as specified and directed. Note:- Supply only liquid water proofing compound shall be measured and paid separately.
M&L for water proofing treatment to roof slab by applying one coat of cold bituminous primer @ 0.30 litre/sqm and confirming to IS-3384, laying APP based polystr modified membrane reinforced non wooven polyster of 3.50 kg/sqm (minimum) 3mm thick with plain polythene finished and sealing all the overlap 75mm in length side and 100mm in width side of membrane by torching including applying one coat of bituminous aluminium paint over membrane all as specified and directed.
Supply only, liquid water proofing compound complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F, galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40mm and fixed wth tinned tacks or galvanized wire staples or wooden bead complete all as specified and directed.
S&F, mild steel angle iron as in posts and struts in fencing cutting top to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mess etc.) including all necessary drilling, bolting or reveting etc. and similar work conforming to Fe-290 (Gde E-165) including errecting in position complete all as specified and directed.
S&F mild steel screw bolts 5 to 10mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc. 5cm long complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified and directed. Note: supply only chain link fencing, MS 10mm dia round bars as line wire and MS flat iron shall be measured and paid separately under respective item of this schedule.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F, Steel rolling shutters, 1.1mm thickness of laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type complete all as specified and directed.
S&F, factory made steel windows with side hung shutter including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded including applying one shop coat of red oxide primer complete all as specified and directed.
Supply only mild steel flat iron, round bars etc. in available length complete conforming to Fe-290 (Gde E-165) complete all as specified and directed. Note:- 10mm dia MS rods 3 Nos shall be provided horizontally by interwewaving in the chain link and welded with MS flat iron.
Supply only mild steel galvanised, chain link fencing of 50x50mm mesh size and 3mm dia wire complete all as specified and directed.
M&L for 50mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/hard standing and finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L for coloured non skid ceramic tiles, 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed.
M&L for coloured non skid ceramic tiles, 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in skirting dado set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 10 mm thick cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 5mm thick in cement mortar 1:4 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces, finished even and smooth without using extra cement , complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surface of wall applying 1.5mm thick wall care putty even and smooth and two coats of oil bound distemper any tint or colour complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper over and including chalk whiting on walls complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc. 0.5sq.m in each pane complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description exc 10cm width or girth and applying one coats of saynthetic enamel paint complete all as specified and directed
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surface of any description not exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25mm bore of pipe complete all as specified and directed.
Supply, hoisting, fixing in position and connecting, in repairs, 500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top), ISI marked, including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
S&F, in repairs, Gun metal, globe or gate valves, with iron wheel head, screwed both ends for 20mm bore of iron pipe and fixed all as specified and directed.
S&F, in repairs, Gun metal, globe or gate valves, with iron wheel head, screwed both ends for 25mm bore of iron pipe and fixed all as specified and directed.
S&F, HDPE water storage tank lid black (with arrangement for locking for 500 litres capacity tank complete all as specified and directed.
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor/walls complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar for 110mm and 75mm bore of pipe from wall/floors etc complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawing through in and including medium grade, rigid non metallic PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories and including with multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire terminating with new modular sunken concealed terminal boxes complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawing through in and including medium grade, rigid non metallic PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories and including with multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire terminating with new modular sunken concealed terminal boxes complete all as specified and directed for the following :-
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete of sizes 10 Sqmm 2 core complete all as specified and directed.
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed
S&F, sheet metal distribution board, SPN, 2 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, miniature circuit breakers, type curve ‘B’ , 10 KA, SPN, 32-40 Amps complete all as specified and directed.
S&F, ceiling fan 1200mm sweep, 230V, AC, 50 Hz, including electronic type fan regulator, single phase electric supply, ISI Marked with all standared fittings including PVC cable 1.5 Sqmm, 3 core, 1100 volts, round from ceiling rose to the fan and writing of MES Nos with black synthetic enamelled paint complete qll as specified and directed.
S&F, LED light fitting retrofit, batten type, housed in extruded from powder coated aluminium, 20 Watt connected with three core copper conductor cable of suitable size and testing complete all as specified and directed as per make Bajaj or equivalent make as approved by GE from the makes specified under Appx 'C'.
Agarwal and Company
Haritwal traders
nevi constructions
Shree Builders
ALBA AC AND REF SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .