Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.0 LAccepted-AOC 37 B PHASE 3 INDUSTRIAL ESTATE GANGYAL JAMMU | 1 | Accepted-AOC 1 | |
| 2 | 2₹5.0 L+₹950 (0.19%)Rejected-AOC GANGYAL JAMMU | 2 | Rejected-AOC 2 | |
| 3 | 3₹5.2 L+₹22,250 (4.49%)Rejected-AOC | 3 | Rejected-AOC 3 |
Tender Value
₹5.0 L
Closing Date
29 Nov 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Akhnoor/Nowshera
Office of the Executive Engineer MID Akhnoor/Nowsh
a) Upgradation by improvement of Bowl Assembly of 20 Cusecs , 40 meters head Jyoti make 2 stage V.T Pump No. 4 of LIS Rajal. (b)Up gradation by way of improvement with allied works of Column Assembly of 20 Cusecs discharge, 40 meters head Jyoti ma
2021_IFC_148435_1
102/MID/AN
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
45 days
Rajal
Please refer Tender documents
7 documents required · 7 mandatory
₹500
Executive Engineer MID Akhnoor/Nowshera
Exempted
Office of the Executive Engineer MID Akhnoor/Nowsh
18 May 2022
17 Nov 2021
30 Nov 2021
17 Nov 2021
29 Nov 2021
18 Nov 2021
20 Nov 2021
180 days
BOWL ASSEMBLY OF PUMPING UNIT NO 04. Strengthening, Improvement of various damaged components of Bowl Assembly of 20 cusec discharge x 40 meter Head, Jyoti make 2 stage VT Pump no. 04 installed at L.I.S Rajal by Rebuilding the A.I.S.I - 410 S.S. closed type impeller by way of rebuilding of all worn out portions including its bore hole and key ways by re-metalling in layers with requisite S.S. welding electrodes and then machining, grinding, polishing, finishing of impeller to attain true size and specifications so as to fit on leaded bronze wearing ring with suitable clearance/allowance. The job including balancing of impeller statically and dynamically. Complete Job.
Strengthening, Improvement of various damaged components of Bowl Assembly of 20 cusec discharge x 40 meter Head, Jyoti make 2 stage VT Pump no. 04 installed at L.I.S Rajal by way of rebuilding of Cast iron bowl case by welding/rebuilding the damaged worn out portions of internal and external surfaces of the bowl case with specified C.I welding electrodes, repair, reconditioning of elongated holes of flanged ends, machining, turning, finishing the main bore hole of bowl to bring it to the true size. Providing & Fitting of new std. nitride compressed rubber bush lined leaded bronze discharge bush in main hole, locking of tight fitted bush with fine threaded copper studs S.S. lock plates and washers, finishing, grinding of external and internal surfaces of bowl case with grinders along with facing the flanged ends, rebuilding, turning, finishing to true size the seat of impeller wearing ring. Also extraction of broken stud by drilling and rethreading of the holes. Complete Job.
Reconditioning of Cast Iron enlarger by way of rebuilding of worn out portions at external and internal housing by re-metalling with superior quality of welding electrodes and then finishing to true size after turning, machining, grinding, alongwith rebuilding reconditioning of elongated holes of flanged ends to std. size. Also Providing and fitting of new std. size nitride compressed rubber bush at the main bore hole. The job also includes providing and fitting of new studs of specified material. Complete Job.
Reconditioning of Cast iron Bell mouth by way of re-metalling the internal and external worn out surfaces, machining, turning and grinding to true size, facing, grinding of flanges to attain proper surfaces, reconditioning of elongated holes of flanged ends to std. size. Also rebuilding, turning and finishing to true size the seat of impellers wearing ring in co-eccentric position having a suitable clearance allowance. Complete Job.
Providing and Fitting of S.S. A.I.S.I- 410 impeller shaft 2.25 m long and 85 mm dia. As per existing sample of Bowl Assembly of 20 cusec discharge x 40 meter Head, Jyoti make 2 stage VT Pump. Job also includes providing and fitting of cotters. Complete Job
Providing and fitting at site Cast Iron stiffener made up from guide spider suitable for pump shaft of size 70 mm dia. with six no. Holes of 24 mm dia. (as per the sample) Complete Job.
Fabrication and Fitting of new leaded bronze impeller wearing ring in rebuilt, reconditioned seat with having proper clearance allowance wearing ring. Complete Job.
Strengthening of M.S. strainer by providing and fitting of new mesh rods at proper spacing, complete with welding of base mesh plate around the periphery. Job includes providing & fitting the same with Bell mouth of the Bowl assembly Complete Job.
Providing and fitting of high tensile steel nut bolts to Bowl assembly of 20 cusecs discharge V.T. pumping unit No 04 24mm x 130 mm bolts with washer and nut washers ( as per sample ) 20 Nos., 24mm x 120 mm bolts with washer and nut washers ( as per sample )20 Nos.
Fabrication, providing and fitting at site half motor coupling pulley as per requisite sample, grade composition/specifications . Job also includes providing and fitting of cotters. Complete Job.
Complete assembling of bowl assembly by way of mounting of 2 Nos. impellers on 85 mm dia. 2.25 m long impeller shaft with 2 Nos. bowl cases, 1 No. enlarger 1 No. bell mouth, 1 No. stiffener in sequence at their respective places with key holding rings, back washers, suitable with required allowances of 2 Nos. impellers and co-eccentric in 2 Nos. leaded bronze wearing and lifting of M.S. strainer to bowl assembly of relevant F.F. sheet at each joint of bowl assembly with replacement of worn out/damaged holding rings. Complete Job.
Charges for Shifting, Transportation (to & fro) of the bowl assembly of Jyoti make 2 stage VT Pump no. 04 installed at L.I.S Rajal from LIS Rajal to Workshop for repairs/Reconditioning and then back from workshop to LIS Rajal after repairs including loading, un loading, handling charges at both ends and hire charges of Mechanical transportation. Complete Job.
COLOUMN ASSEMBLY OF PUMPING UNIT NO 04 Strengthening, Replacement of various damaged components of Column Assembly of 20 Cusecs discharge, 40 meters head, V.T Pump no 04 1installed at L.I.S Rajal by way Fabrication and providing at site top shaft sleeve of dia.70 mm made out of stainless steel A.I.S.I-410 grade ( as per sample.) also reconditioning of A.I.S.I-410 top shaft 2315 mm long x 70 mm dia by way and re-metalling the worn out undersize portions with special s.s welding electrodes in layers and then turning, grinding, polishing, finishing to true size. Also removing checking eccentricity of top shaft with dial gauge at various off sets. Removing deflection eccentricity by heat treatment or on hydraulic press. Removing of deflection on heads/ends and then again checking the alignment of shaft on lathe machine. P/F of new fabricated A.I.S.I-410-S.S cotter pins along with reconditioning of key ways. Also rebuilding the threaded portion of the shaft and its nut with re-metalling with S.S. welding electrodes, turning, finishing to true size and then rethreading the nut and the reqd. portion of the top shaft. Complete Job.
Reconditioning of C.I. guide spider by way of rebuilding, reconditioning of elongated holes of flanged ends to std. size, extraction of broken studs of rubber pad housing bush. P/F of new std. size nitride compressed rubber bush 1 No. rubber pads 3 Nos. with nut bolts, rethreading tapping the oversize holes and fitting of new manufactured studs of cover plates. Complete Job.
Providing and Fitting of C.I guide spider as per requisite sample, grade composition/specifications fitted with nitrile compressed rubber bush 1 No., thrust pad 3 Nos. ,M.S cover plate for bush along with 20 mm dia. X 50 mm long high tensile steel bolt with washer to column assembly of 20 cusecs discharge Jyoti make V.T. pump. Complete Job.
Reconditioning of A.I.S.I-410-S.S. muff coupling along with its top and bottom nut by way of rebuilding at worn out portions with re-metalling with S.S. welding electrodes, turning, finishing to true size and rethreading the nuts and reqd. portions of cylinder with facing, turning all surfaces of nut and cylinder for proper fitment along with rebuilding of key ways. Complete Job.
Fabrication , providing and fitting of A.I.S.I-410-S.S muff coupling of size of length 300 mm and bore size to suit line shaft of dia. 70 mm along with its top & bottom split nuts and keyways. The machining should be done accurately for proper fitment and removal as and when desired during dismantling of column assembly.( as per sample.) Complete Job.
Fabrication and providing at site heavy duty E.R.W flanged shaft enclosing tube of 200 mm. dia. x 2180 mm long , 6/8 mm. thickness having flanges on either side ( welded on inside of pipe ) with drilled and threaded 6 nos holes to suit M 20 x 50 mm bolts ( as per sample.). Complete Job.
Reconditioning of C.I. stuffing box by way of rebuilding reconditioning of deformed holes of flanged ends to std. size. P/f of new std. size nitride compressed rubber bush. Extraction of old broken studs, rethreading, tapping the oversize holes and fitting of 2 Nos. studs with nut washers. Also rebuilding the worn out portion of leaded bronze gland bracket and turning grinding finishing to true size. Complete Job.
Reconditioning of M.S. deflector tube 200 mm dia. 2.315 m long by way of cutting removing of damaged flanged ends. Fitting welding on each end of the new fabricated flanges as per sample specifications. Also repair to the under size fins of the deflector tube by way of welding, patching at worn out places to attain reqd. shape and size specifications. Straightening, aligning the tube and facing the ends as per proper alignment. Complete job includes cutting of approximately one and a half feet damaged piece of pipe from the worn out/ damaged thread side and fabricating and welding with proper alignment the new piece of pipe with thread as per sample. Complete Job.
Rebuilding/Reconditioning of 200 mm dia. E.R.W shaft enclosing tube by way of cutting removing of damaged flanges. Fitting welding of new fabricated of flanges as per sample specification at each end of the tube and facing the end as per proper alignment. Also straightening alignment of the tube on hydraulic press. Complete Job.
Reconditioning of M.S. 500 mm diameter X 2.18 mtrs. long column pipe by way of rebuilding the worn out and under size portions at each and where guide spiders came in contact with surface of the column pipe by re-metalling with superior quality of welding electrodes and then turning, grinding facing and alignment of the repaired portion of the pipe to attain true size along with rebuilding reconditioning of elongated holes of flanges to std. size, checking and removing ovality etc. Job including handling charges. Complete Job.
Reconditioning of S.S. A.I.S.I-410 or IS – 1570 carbon steel material 2.18 m long X 70 mm dia. line shaft by way of reconditioning of worn out under size portions with special S.S. welding electrodes in layers and then turning grinding, polishing, finishing of key ways. Also removing, checking, on eccentricity of line shaft bolts dial gauge at various off sets. Removing deflection/eccentricity by heat treatment or on hydraulic press. Removing of deflection on heads/ends and then again checking the alignment of shaft on Lathe machine. P/F of new fabricated A.I.S.I-410-S.S. line shaft cotter pins. Complete Job.
Providing and fitting of high tensile steel nut bolts to column assembly of 20 cusecs discharge V.T. pumping unit No 04 24mm x 100 mm bolts with washer and nut washers ( as per sample) 30 Nos., 22mm x 50 mm bolts with washer and nut washers ( as per sample ) 30 Nos., 20mm x 50 mm bolts with washer and nut washers ( as per sample ) 30 Nos. Complete Job.
Assembling of each column assembly one by one external and internal 500 mm dia. X 200 mm dia. X 70 mm dia. line shafts in sequence and lowering into the pit along with assembled bowl assembly. This incl. fitting/lowering of five Nos. line shafts, guide spiders, muff couplings, top shaft tension/deflector tube & column pipes. Jointing of discharge surging head with delivery pipe 500 mm dia. along with P/F of relevant jointing material F.F. sheet, graphite grease packing 16 mm2. Placing of base frame on box plate. Fitting, tightening. Complete Job.
(a)Testing, commissioning of pumping unit No. 04 including installation of 300 K.W / 400 H.P 6.6 K.V H.T B.H.E.L make solid shaft motor skirt by fitting motor half coupling with pump half coupling. Fitting of cable connections of the motor (stator and rotor) L.R.S. commutator assembly, space heater sealing box, cleaning of carbon brushes, proper alignment/adjustment of column assembly. Checking panel wire connections and running motor for complete, re commissioning of pumping unit . (b) Providing and fitting of 16mm x 180mm high tensile steel coupling bolts with nut washer 06 Nos. (c) Providing and fitting of 16mm x 65mm high tensile steel coupling L-key bolts with washer 06 Nos. Job includes Shifting, Transportation (to & fro) of the column assembly of Jyoti make 2 stage VT Pump no. 04 installed at L.I.S Rajal from LIS Raja to Workshop for repairs/Reconditioning and then back from workshop to LIS Rajal after repairs including loading, un loading, handling charges at both ends and hire charges of Mechanical transportation. Complete Job
HITECH MECHNICALS
KHALSA ENGG. WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .