Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹48.8 L+₹11.0 L (29.1%)Accepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Accepted-AOC Lowest Bonafide Tender | |
| 2 | L1₹37.8 LRejected-Finance | L1 | Rejected-Finance NON-BONAFIDE TENDER | |
| 3 | L3₹49.5 L+₹11.7 L (31.0%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹49.7 L+₹11.9 L (31.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
19 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
MANNING AND OPERATION OF VARIOUS AC PLANTS AT AFS AMLA
2020_MES_341472_1
8368/E8 of 2020-21
Open Tender
Air-Conditioner
Item Rate
3000 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹99,000
Yes
2 Jun 2020
28 Apr 2020
21 May 2020
28 Apr 2020
19 May 2020
5 May 2020
60 days
Amount
AC plant No - 4 Outsourcing services round the clock for manning and operation of AC Plant No-4 (central direct expansion type) of capacity 4 x 8.5 TR (4 x 8.5 TR plants to be run at a time and 2 x 8.5 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No 4 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 4 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 8.5 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 5 Outsourcing services round the clock for manning and operation of AC Plant No-5 (central direct expansion type) of capacity 4 x 8.5 TR (4 x 8.5 TR plants to be run at a time and 2 x 8.5 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-5 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 5 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 8.5 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 6 Outsourcing services round the clock for manning and operation of AC Plant No-6 (central direct expansion type) of capacity 4 x 8.5 TR (4 x 8.5 TR plants to be run at a time and 2 x 8.5 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-6 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 6 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 8.5 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 13 Outsourcing services round the clock for manning and operation of AC Plant No-13 (central direct expansion type) of capacity 2 x 15 TR (2 x 15 TR plants to be run at a time and 1 x 15 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-13 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 13 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 15 TR -3 Nos (c ) Compressor Motor 20 HP -3 No. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 7.5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-2 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Strip Heater 3 KW - 12 Nos and (l) water softner plant pump 0.5 HP - 2 Nos
AC plant No - 21 Outsourcing services round the clock for manning and operation of AC Plant No-21 (central direct expansion type) of capacity 4 x 8.5 TR (4 x 8.5 TR plants to be run at a time and 2 x 8.5 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-21 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 21 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 8.5 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 53 Outsourcing services round the clock for manning and operation of AC Plant No-53 (central direct expansion type) of capacity 2 x 10 TR (2 x 10 TR plants to be run at a time and 1 X 10 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-53 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 53 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 10 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 54 Outsourcing services round the clock for manning and operation of AC Plant No-54 (central direct expansion type) of capacity 2 x 12 TR (2 x 12 TR plants to be run at a time and 1 X 12 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-54 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 54 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 12 TR -3 Nos (c ) GI pipe line - 80 RM (Appox) (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP -1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox)
AC plant No - 57 Outsourcing services round the clock for manning and operation of AC Plant No-57 (central direct expansion type) of capacity 2 x 10 TR (2 x 10 TR plants to be run at a time and 1 X 10 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-57 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 57 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 10 TR -3 Nos (c ) Compressor Motor 15 HP -3 Nos. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
AC plant No - 84 Outsourcing services round the clock for manning and operation of AC Plant No-84 (central direct expansion type) of capacity 2 x 10 TR (2 x 10 TR plants to be run at a time and 1 X 10 TR will be kept as stand by) alongwith all connected equipments and accessories at Shed No-84 including keeping the installation clean, rectifying minor repairs and day to day routine maintenance of cooling tower, compressor etc., by engaging 3 (three) Nos of Refringent Mechanic (skilled) i.e. (01 No for each shift of 08 Hrs) on all the days of calendar month including Sundays and holidays with reliever on duty complete all as directed. (A) Details of equipment at AC plant No. 84 are as under: - (a) LT Panel - 1 No (b) Compressor capacity 10 TR -3 Nos (c ) Compressor Motor 15 HP -3 No. (d) Condenser - 3 Nos (e) Blower (AHU) - 1 Nos. (f) Blower Motor 5 HP - 1 Nos (g) Cooling Tower - 1 Nos. (h) Cooling Tower Motor - 1 Nos. (i) Condenser water Pump 5HP-1 Nos (j) CI pipe 80 mm dia - 140 RM (Appox) (k) Hot water Generator with heating element 3 KW - 8 Nos (l) Hot water circulating pump 0.5 HP - 2 Nos
Important notes for item no. 1 to 9: - (i) The rate quoted shall not be less than minimum wages as notified by Government of India/State Government/Local body whichever is higher including all statutory provisions such as EPF, ESIC, Bonus, taxes etc as applicable. In case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher including all statutory provisions such as EPF, ESIC, Bonus, taxes etc as applicable, his tender will be treated as non bonafide and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid/bonafide bids only. (ii) Refringent Mechanic - 03 No (01 No for each shift of 08 Hrs) (iii) Work to be carried out in 03 (three) shifts 06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs (iv) Contractor should maintain User/Engineer-in-charge recommended temperature and Humidity inside the AC plant. (v) Contractor should make necessary arrangements in case of any emergency to ensure smooth functioning of system without failure throughout all the three shifts the rate quoted deemed to be inclusive of this provision. (vi) Contractor shall provide necessary Log books/ Stationary required for recording the running of the AC plant and connected equipment’s as per the sample provided by the Department. (vii) Contractor shall provide Consumables like cotton waste, grease, etc for day to day maintenance of AC pant and connected equipment’s. (viii) Contractor shall provide necessary uniform & protective clothing for the people employed with the name and firm name to be printed on the uniform as approved by GE. (ix) Contractor shall provide necessary Tools for routine maintenance & operation of installation. (x) Daily routine/ scheduled maintenance of equipment’s installed at AC plant shall be carried out as per PS. (xi) The qualification and experience of tradesmen employed shall be as mentioned in PS. (xii) All the people deployed shall be police verified. (xiii) All the people deployed shall be issued with photo identity card. (xiv) All the Labour laws shall be followed and minimum fair wages to be paid to the people deployed as per the labour law through Aadhar liked Bank A/C. (xv) The rate quoted by contractor deemed to be inclusive of all the above provision and no extra claim is entertained on this account
Shri Sai Enterprises
M/S SHARADA ASOCIATE
MODI CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .