Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 2 | Admitted-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) Tezpur
GE (N) Tezpur Co 99 APO
CERTAIN REPAIRS AND MAINT OF EXTERNAL LT DISTRIBUTION CABLES AND CONNECTED ITEMS IN CERTAIN UNITS LOCS OF NAA UNDER GE (N) TEZPUR
2021_MES_424398_1
GE(N)/TEZ/2020-21/8462
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Tezpur
As per tender docus
8 documents required · 8 mandatory
₹500
GE (N) Tezpur
₹40,000
Yes
25 Mar 2021
22 Feb 2021
24 Mar 2021
22 Feb 2021
22 Mar 2021
8 Mar 2021
23 Feb 2021 - 2 Mar 2021
60 days
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down old broken PCC/ Steel pole of any size and Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 using 40mm graded sone aggregate for foundation and coping with PCC 1:2:4 using 20mm stone aggregate and smooth finish complete all as specified and as directed.
M&L in replacement of shackle type Insulator porcelain vitreous white/ brown or green, 75 mm high and 90mm dia suitable for working pressure of 1100 Volt including Galvanized mild steel straps of size 31x3 mm , nut, bolt of dia 12 mm and washers of suitable size, complete all as specified and directed.
M&L in replacement of pin Insulators Porcelain vitreous white or green including Galvanized mild steel spindle, two GI washers and one GI nut of size suitable for 1100 Volt electric pressure complete all as specified and directed.
Restringing of LT overhead lines comprising ACSR conductors of any size after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
M/L in replacement for cross arms, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified.
Taking down the old U/S / broken ACSR conductors from pole and, Material and labour for aluminium conductor, steel reinforced (ACSR) of any size, stringing properly on insulators on pole and binding with aluminium tape / binding with conductors, junpers etc complete all as specified and directed.
M & L for stay assembly in replacement comprising of 7/2.24mm galvanised MS stranded wire of required length fixed to pole with and including flat iron clamps fabricated out of 50 x 6mm flat iron and iron nuts, bolts and washers of suitable size, 40 cm long 14 mm dia galvanised MS stay bow, 215 cms long 20 mm dia stay rod threaded end with nuts and washers, MS stay plate galvanised 230 x 230 x 6mm, two thimble, loop insulators of size 65 x 90mm, clearance dia of hole 16 mm, including necessary excavation and earth work and PCC 1:3;6 using 40mm stone aggregate as in for foundation complete all as specified and as directed.
Supply and fixing of GI strip 32 x 6 mm fixed in ducts / on wall etcfor connection to equipment / test point / earth electrode etc complete all as specified and directed
Taking down old broken GI wire & Supply, laying, and stringing GI earth wire on poles for continuous earth wire and cradles hexagonal / rectangular fabricated out of 4 mm dia galvanised steel wire including and binding complete all as specified and directed
Taking out unserviceable UG Cables of any Cross Sectional Area from trenches/ wall/ poles etc, after its disconnections, complete all as specified and as directed. NOTE : Earthwork will be measured and paid under appropriate Items.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes;-
ditto but of size 70 sq mm, 3.5 core.
ditto but of size 95 sq mm, 3.5 core.
ditto but of size 25 sq mm, 4 core.
S&F Galvanised Iron Pipe 80mm bore (dia), Light grade for protection of UG Cable, complete all as specified and as directed.
S&F Galvanised Iron Pipe 40mm bore (dia), Light grade for protection of UG Cable, complete all as specified and as directed.
Excavation in trenches in soft and lose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers in soft / loose soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable in trenches for protection of cables and punned down to a thickness of 180mm complete all as specified and directed.
Supply and laying in trenches brick common burnt clay, sub class 'B' designated- 75 laid width wise equal to length of cable for protection complete
Taking down of U/S MCCB of any Size from panel after disconnection of its cables complete all as specified.
Supply and fixing MCCB 415 volt, AC 50Hz, 4 pole, 36 KA with micro processor release, conforming to IS/IEC 60947-2 with adjuustable over load and short circuit conditions (160-400A) of capacity 400 Amps, Cat No; CM93003OOOOX1 of L&T or equivalant in Legrand/Schneider/ABB
Supply and fixing MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions (200-250) of capacity 250 Amps.Cat No; CM90642OOPO of L&T or equivalant in Legrand/Schneider/ABB
Supply and fixing MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions (160-200) of capacity 200 Amps.Cat No; CM90642OONO of L&T or equivalant in Legrand/Schneider/ABB
Supply & Fixing in replacement MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with fixed thermal magnetic tripping system against over load and short circuit conditions (125-160) of capacity 125 Amps Cat No; CM90642OOLO of L&T or equivalant in Legrand/Schneider
Supply & Fixing in replacement MCCB 415 volt, AC 50 Hz, 4 pole, 25 KA with fixed thermal magnetic tripping system against over load and short circuit conditions (80-100)of capacity 100 Amps Cat No; CM1712OOKOOG of L&T or equivalant in Legrand/Schneider
Material & labour for carrying out repairs to the APFC Panels including servicing / replacing wornout nuts, bolts, cable lugs, connecting wires, markers, insulating sleeves, repairs to PCC foundation etc and repacement of power capacitors with equal or higher capacities, capacitor switching duty contactor, suitable APFC Relay, HRC Fuse links etc all as directed including reinstallation at original or at a new location all as directed. (Repacement of power capacitor, capacitor switching duty contactor and APFC Relay, HRC Fuse links will be measured separately but cost for the the rest items required to make the APFC controller functional to achieve best result should deem to be included in the rate).
Supply and fixing Power factor correction Capacitor heavy duty of following capacities of Make:- L&T or equivalent in shneider/ABB
10 KVAR, Type LTCCR.
20 KVAR, Type LTCCR.
Supply and fixing APFC Relay suitable for Banks upto 8 steps of Cat No: ETACONM008R of Make: L&Tor equivalent of ABB/ Schneider.
Supply and fixing 3 Ø 415 V 50 HZ Capacitor switching duty contactor suitable upto 25KVAR rating of type MO C 20, Cat N: CS90021 of L&T or equivalent in ABB/ Shneider.
Digital Panel mounted LED Multy Function Meter 96 X 96 mm suitable for measuring Parameters,V,A,F,KW,PF on hours & KWH, etc.Cat Part No:WL404010OOOO of L&T or Equivalent in Shneider/ABB.
CT for measuring AC on LT 3 phase system, 1.1 kv grade, single burden, general purpose, of CT ratio as per site requirement.
LED Indicator Lamps for phases including holders and of colours red / yellow / green / blue etc.
Bakelite kit kat fuse base with fuse holder complete and all as directed and as specified upto 32A rating.
Material and labour for painting to steel tubular pole 9.00/11.0 metre long with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with alluminium paint and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified.
Material and labour for numbering of pole no. Using stensils of letter height 50mm with two coats of Black round and fonts with white in colour complete all as specified.
Supply and fixing PVC line seperator suitable for 2 conductor complete all as directed.
Supply and fixing PVC line seperator suitable for 4 conductor complete all as directed.
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/LT overhead lines /feeders(including reparing and jointing of ACSR conductor if damaged during cutting of trees) and removal of trimmed branches of tree and depositing the same in waste bin inside the campus all as specifed and directed. ( Span length not more than 50 mtr)
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion , complete all as specified and directed.
Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.0mm thick CRCA steel sheet of suitable size and and angle iron 40x40x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprice of following items and all specified in SSR part -I clause No 19.21. Busbar: 160 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance. Incoming: (a) MCCB, 4 pole, 415 volts,50 Hz,100Amps18KA breaking capacity -1No with thermal magnetic release, adjustable Over load and short circuit settings,Cat Part No:CM90518OOKO of L&T or Equivalent in Shneider/ABB. (b) Multi function Meter 4410, class 1-1 No, Cat Part No:WL441010OOOO of L&T or Equivalent in Shneider/ABB, with CTs of Suitable capacity-1Set. (c) Indicator lamp LED type R-Y-B-1 set. Outgoing: (a) MCCB, 4 pole, 415 volts,50 Hz,63 Amps18KA breaking capacity -3 Nos with thermal magnetic release, adjustable Over load and short circuit settings,Cat Part No:CM90518OOHO of L&T or Equivalent in Shneider/ABB..
S&F ACB, 4 pole manual fixed , 415 volts,50 Hz,630Amps, 50KA breaking capacity -1No with Micro processor release, adjustable Over load, short circuit and earth fault settings, Cat Part No:SL95581 of L&T or Equivalent in Shneider/ABB.. in existing LT Panel including taking out old U/S ACB from main panel duly disconnecting LT cables and reconnecting with new ACB, including testing & commissioning complete all as directed by Engineer-in-charge.
Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.0mm thick CRCA steel sheet of suitable size and and angle iron 50x50x6mm, grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprice of following items and all specified in SSR part -I clause No 19.21,and connecting up all the LT UG cables. Busbar: 600 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance. Incoming: (a) MCCB, 4 pole, 415 volts,50 Hz, 400Amps, 36KA breaking capacity -1No with thermal magnetic release, adjustable Over load and short circuit settings,Cat Part No:CM98403OOQROOG of L&T or Equivalent in Shneider/ABB. (b) Multi function Meter 4410, class 1, Cat Part No:WL441010OOOO of L&T or Equivalent in Shneider/ABB, with CTs of Suitable capacity-1Set. (c) Indicator lamp LED type R-Y-B-1 set. Outgoing: (a) MCCB, 4 pole, 415 volts,50 Hz,160 Amps18KA breaking capacity -4 Nos with thermal magnetic release, adjustable Over load and short circuit settings, (b) MCB TPN, 415 Volts, 50Hz, 25Amps - 2No, (c) 4 pole power contactor type MCX 02-1No, Cat Part No:CS97010 of L&T or Equivalent in Shneider/ABB (d) Austro time switch-01 No, cat No: AUSTS02AST00,of L&T or Equivalent in Shneider/ABB
Shree Krishna Traders
Anil Kumar Sarmah
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .