| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.5 LAccepted-AOC | ₹49.5 L Quoted ₹50.8 L | 1 | Accepted-AOC L1 BIDDER |
| 2 | 2₹51.6 L+₹83,069 (1.64%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | ₹51.6 L+₹83,069 (1.64%) | 2 | Rejected-Finance NOT L1 BIDDER |
| 3 | 3₹52.3 L+₹1.5 L (3.02%)Rejected-Finance | ₹52.3 L+₹1.5 L (3.02%) | 3 | Rejected-Finance NOT L1 BIDDER |
| 4 | 4₹52.4 L+₹1.6 L (3.11%)Rejected-Finance | ₹52.4 L+₹1.6 L (3.11%) | 4 | Rejected-Finance NOT L1 BIDDER |
| 5 | 5₹52.4 L+₹1.6 L (3.13%)Rejected-Finance | ₹52.4 L+₹1.6 L (3.13%) | 5 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Aug 2023, 5:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
COMPREHENSIVE MAINT OF MISC STRUCTURAL REPAIR DAMPNESS LEAKAGE SEEPAGE ROOF TREATMENT FLOORING REPAIRS TO COLUMNS FINS FACIA RAINWATER PIPES FLOORING PLASTERING PLINTH PROTECTION INTERNAL WS LINE WCS, WHB PVC DOORS WATER TANKS AND INTERNAL ELECTRIFI
2023_MES_610312_1
8282/23-24/GE(N)/KOL/E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
2 CBPO
AS PER TENDERDOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹98,000
Yes
11 Sept 2023
22 Jul 2023
12 Aug 2023
23 Jul 2023
11 Aug 2023
4 Aug 2023
Amount
Taking up or down 15mm dia steel tubing and connections, segregating serviceable pipe for reuse complete all as specified and as directed.
All as per item No. 1 above but 20mm dia complete all as specified and as directed.
All as per item No. 1 above but 25mm dia complete all as specified and as directed.
Supply and fix 15mm bore medium grade galvanized steel tubes with all fittings and fixed to wall or in floors etc complete all as specified and as directed.
All as per item No. 4 above but 20mm dia complete all as specified and as directed.
All as per item No. 4 above but 25mm dia complete all as specified and as directed.
Refixing of serviceable GI pipes 15mm bore obtained from Item No. 1 here-in-before after cleaning in new or old positions complete all as specified and directed.
Refixing of serviceable GI pipes 20mm bore obtained from Item No. 2 here-in-before after cleaning in new or old positions complete all as specified and directed.
Refixing of serviceable GI pipes 25mm bore obtained from Item No. 3 here-in-before after cleaning in new or old positions complete all as specified and directed.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
Refixing of shutters obtained from Item No. 12 above in same opening of any description exceeding 1 sqm each and not exceeding 2 sqm each with old serviceable / with new builders hard ware articles if any complete all as specified and directed.
Taking down old unservicebale steel window/ventilators frame with shutter of any description complete all as specified and directed.
Supply and fix factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles)with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on back face ,with particle board core ,supplying and fixing in frame at site as per specification and drawing complete all as specified and directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube with EPDM gasket as per specification and drawing complete all as specified and directed.
Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification and drawing complete all as specified and directed.
Supply and fix in repairs prelaminated particle board 18/19 mm thick, interior grade one side decorative choice lamination and other side balancing white lamination fixed in cup boards shutters with 6mm thick teak wood lipping/edging all round complete all as specified and directed.
Supply and fix in repairs prelaminated particle board 18/19 mm thick, interior grade one side decorative choice lamination & other side balancing white lamination fixed in cup boards shelves with front side 6mm thick teak wood lipping/edging complete all as specified and directed.
Supply and fix 100 mm size butt hinges, medium weight, stainless steel and fixed complete all as specified and as directed.
Supply and fix 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 150mm size extruded aluminum alloy handle fabricated type anodized (ISI Marked) complete all as specified and as directed.
Supply and fix in repair 100mm long hasp and staple, safety type, brass with mild steel hinges pin including bolt to hinge plate and fixed with brass screw complete all as specified and directed.
Supply and fix in repair 3mm thick frosted glass ordinary quality, glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed to steel frame complete all as specified and as directed.
Supply and fix rolled mild steel Fe-410-w (grade E-250) quality A framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work complete all as specified and as directed.
Supply and fix 3mm thick sheet glass, ordinary quality and glazing each pane fixed to steel frame(fixed with oil putty and clips)/wooden frame(fixed with Iind cl hard wood beads) including hacking out old broken glass from metal frmae/wooden frame complete all as specified and as directed.
Supply and fix 3mm thick frosted glass, ordinary quality and glazing in each pane fixed to steel frame(fixed with oil putty and clips)/wooden frame(fixed with Iind cl hard wood beads) including hacking out old broken glass from metal frmae/wooden frame complete all as specified and as directed.
Supply and fix stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to new steel surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and directed.
Supply and fix aluminium powder coated glazed or gauged shutter for sliding window (2 or 3 track) with aluminium channel section weighing not less than 0.55 kg per sqm including aluminium channel,including all necessary fittings such as roller, joining cleats, glazing clips, rubber packing aluminium screw as required etc. complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators (including 2/3 track) with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply and fix aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified.
Supply and fix 4mm thick sheet glass ordinary quality, glazing with aluminium beads in square/rectangular exceeding 0.5 Sqm in each pane fixed to aluminium frame complete all as specified and as directed.
Supply and fix 5.50mm thick sheet glass ordinary quality, glazing with aluminium beads in square/ rectangular exceeding 0.5 Sqm in each pane fixed to aluminium frame including, rubber packing aluminium screw as required complete all as specified and directed.
Supply and fix in repair 25mm dia powder coated aluminium curtain rod fancy type( length from 0.90m to 1.5m)with fancy type end side brackets and fancy type hanging brackets complete all as specified and directed.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass, other parts made of mild steelheavy duty and fixed complete all as specified and directed.
M&L for cast brass pivot suitable for aluminium door, complete all as specified and directed.
S&F Brass 2 lever Mortice lock, vertical type, size 100 mm complete all as specified and directed.
Supply and fix in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
Supply and fix in repair angular stop cock of 15mm bore fancy type, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed.
Supply and fix in repair chromium plated two ways bib cock with wall flange for fixing in 15 mm dia pipe complete all as specified and as directed.
Supply and fix in repair health faucet (ABS body) with 8mm dia 1 meter long flexible tube and wall hook for fixing in 15 mm dia pipe complete all as specified and as directed.
Suply and fix in repairs stainless steel sink with drainage board made out of 1.00 mm thick sheet for kitchen with plug washers, waste pipe including bedding in cement mortar on dwarf wall or including cast iron cantiliver brackets connecting union overall size 915 X 460 mm with bowl size 405x355x178mm or 410x357x178mm complete all as specified and as directed (Model No.BSSBSD-52 of Blue Star/SBSD 05 of Joyna/ Equivalent brand of Prayag).
Supply and fix in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including 'P'or 'S' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and directed.
Supply and fix in repair Vitreous china EWC 'P' or 'S' Trap of size 400x365x540mm, white including Plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for EWC (excl flushing cistern and flush pipe) complete all as specified and directed.
Supply and fix in repair 15mm bore Bib tap (Minimum weight 90gms) standard of PTMT any colour high pressure screwed for iron pipe complete all as specified and as directed.
Supply and fix in repair 15mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90gms) complete all as specified and as directed.
Supply and fix in repairs PVC connection 15mm size with PTMT nuts of length 600 complete all as specified and directed.
Supply and fix in repair 10 litre capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern including PVC connections 15mm size with PTMT nuts and washer both side of length 450mm complete all as specified and as directed.
Supply and fix in repair vitreous China wash basin white flat back, size 630 x 400 mm including PTMT waste coupling 32mm dia (min wt 45 gm), 15mm bore PTMT pillar tap, chain, plug and porcelain stopper etc. complete all as specified and as directed.
Supply and fix 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
Supply and fix in repair Brass chromium plated Tubular Towel Rail , 20mm dia, D type, 600mm long between flange fixed with chromium plated brass screws complete all as specified and as directed.
Supply and fix in repair 100mm cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed.
Supply and fix 20mm bore gun metal, gate or globe valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs PVC (SWR) pipe 110mm bore, type A, single socketed, in any length with rubber ring joints fixed to walls with and including PVC clip complete all as specified and directed.
Supply and fix PVC (SWR) bend/ shoe 110mm dia complete all as specified and directed.
Dismantling of old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
Material and labour for Light shade Vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles exc. 0.18 sqm but n.exc. 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for Light shade Vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles exc. 0.18 sqm but n.exc. 0.36 sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for glazed ceramic colour tiles 300x200x7mm thick in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 20mm thick plaster in CM (1:4) in two layers, i.e 10mm thick in each layer, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified and as directed. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing liquid compound for concrete and mortar complete all as specified and as directed.
Material and labour for rendering 05mm thick in cement mortar (1:3) on concrete surfaces in ceiling and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for applying wall care putty 1.50 mm thick and applying two coats of oil bound distemper over a coat of alkali resistant primer on new plaster surface of wall etc complete all as specified and as directed.
Material and labour for preparation of old treated plastered surfaces of wall by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper complete all as specified and as directed.
Material and labour for preparation of old treated plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
Taking down/dismantling loose/damage concrete including plaster of any description and in any position from RCC structures like chajja, fins, roof ceiling,louvers, parapet, column, beam, and of lintel by hammering with wooden mallets carefully chipping off the old concrete surface with necessary scaffolding including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises, including cleaning the existing surface of concrete and reinforcements as obtained after dismantling by wire brush including scrapping & cleaning with emery paper or by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc and washing down with water as required complete all as specified and as directed.
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm complete all as specified and directed. ( Make : SIKA/FOSROC or any other equivalent as approved by GE )
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. ( Make : SIKA/FOSROC or any other equivalent as approved by GE )
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed. ( Make : SIKA/FOSROC or any other equivalent as approved by GE )
Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible . The mortar can be applyied in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 upto 25 mm average thickness complete all as specified and directed. ( Make : SIKA/FOSROC or any other equivalent as approved by GE )
Material and labour for 5 mm thick plastering in CM (1:3) on concrete surfaces as in sides of column, lintel, beam, chajja, facia, railing, RCC wardrobe etc including finishing the surface even and fair without using extra cement complete all as specified and as directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished concrete surfaces complete all as specified and as directed.
Use and waste of formwork to sides of sides and soffits of beams, lintels, floors etc. for rough finished concrete surfaces complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Material and labour for 40mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in floors finished even and smooth without using extra cement complete all as specified and as directed.
Materials and labour for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in pavement/ plinth protection , laid in bays and joints shall be filled up with bituminous gola with 80/25 bitumen ( 1 part of bitumen to be mixed with 3 part of sand and finished the surface fair and even complete all as specified and directed.
Dismantling wrought iron for mild steel work for any description not otherwise provided for complete all as specified and directed.
Supply and fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and as directed.
Dismantling Asbestos cement / Transluscent ( Corrugated , semicorrugated etc.) sheets as in Roof covering , wall , ridge , hips valleys and flashings etc for the building structures not exceeding 10 m height from the average ground level complete all as specified and as directed.
Supply and fix of pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
Supply and fix of pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws as specified complete all as specified and as directed.
Material and labour for providing cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in foundations filling complete all as specified and as directed.
Demolition of reinforced cement concrete of roofs, floors , staircases, landing, chajjas and similar suspended works in ground floors beams (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type A1 (1:1.5:3) (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed. Note: Reinforcement and formwork shall be measured and paid separately.
M&L for reinforced cement concrete (nominal mix) type A1 (1:1.5:3) (using 20mm graded stone aggregate)as in chajja complete all as specified and directed. Note: Reinforcement and formwork shall be measured and paid separately.
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed
Material and labour for TMT bars 6 to 8mm bar, cut to length, bent to shape required, including cranking, bending, lapping etc as required and welding with existing bar complete all as specified and as directed.
Material and labour for TMT deformed bar or twisted bars upto 10mm dia as in stirrups cut to lenth bent to shape required including cranking ,bending etc and lapping ,welding as directed to the existing one complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for flat rough finished concrete surfaces complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc. 15 cm thickness below or above ground level complete all as specified and as directed.
M&L for Hardcore of gauge exc.63mm but not exc. 100mm ,deposited,spread and levelled in layers n.exc. 15cm thick, watered/ rammed to a true surface complete all as specified and directed.
Material and labour for providing 75mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed
Material and labour for 300x300 x25 mm thick PCC designer Pre-polished tiles (Factory make and approved size) as in floors, set & jointed in neat cement slurry and pointed in coloured cement with pigment over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs,pillars,window -cills, cooking platforms and like in cement mortar(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
Demolition of cement concrete of any description including any treatment there to and in any position provided as in roof padding, roof kerb etc complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of old debris/retrieved material to outside the premises or as directed by the Engineer-in-Charge.
Material and labour for providing plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after.
Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment :- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (MAKE : Pibial Primer of TEXSA or equivalent product of BITUMAT/ BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced (4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 4 Kg mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (Note :- Cost of cutting groove to parapet wall for inserting APP membrance and filling groove with cement mortar (1:3) is deemed to be included within the quoted rate.)
Supply and fix in repair Rotational moulded polyethylene water storage tanks (multi layer) 1000 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Supply and fix in repair Rotational moulded polyethylene water storage tanks (multi layer) 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
INTERNAL ELECTRIFICATION Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside to store in safe custody or for taking credit including making good of the disturbed surfaces complete all as specified and directed.
Taking down old unserviceable items such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully including making good of the disturbed surfaces complete all as specified and directed.
Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC casing-N- caping (medium duty) double lock type,size of casing caping as required at site but not less than 20mm with fittings and accessories pressed steel sunken terminal box in concealed made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light point controlled by one 5 Amp one way switch complete all as specified and as directed.
All as per item No 112 here in above but for one fan point controlled by one 5 Amp switch complete all as specified and as directed.
All as per item No 112 here in above but for One 3/5 pin 5/6 Amp Socket outlet on the independent board complete all as specified and as directed.
All as per item No 112 here in above but for One 5 pin socket outlet 05 Amp on same board complete all as specified and as directed.
All as per item No 112 here in above but for One bell/buzzer point controlled by one push button same board with other switch or independent complete all as specified and as directed.
All as per item No 112 here in above but for One light point controlled by two 2 way switch complete all as specified and as directed.
All as per item No 112 here in above but for one 15/16 Amps socket outlet but using 2.5 sq mm,copper conductor with 2.5 sq mm PVC insulated single core cable for earth continuity conductor complete all as specified and as directed.
Material and labour for point wiring (Concealed type) with PVC insulated FRLS (Fire Retardant Low Smoke) cable 1100 volts grade unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories pressed steel sunken terminal box made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified and as directed. Note: Chases cutting and making good to disturbed surfaces shall be measured and paid separately)
All as per item No 119 here in above but for One 3/5pin 6 Amp Socket outlet on the same board with other switches complete all as specified and as directed.
All as per item No 119 here in above but for One 3/5pin 6 Amp Socket outlet on the independent board complete all as specified and as directed.
All as per item No 119 here in above but for One call bell point controlled by one bell push switch complete all as specified as directed.
All as per item No 119 here in above but for one light point controlled by two 2 way modular switch complete all as specified as directed.
Material and labour for point wiring (Concealed type) with PVC insulated FRLS(Fire Retardant Low Smoke) cable 1100 volts grade unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase, neutral and 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories pressed steel sunken terminal box made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for 3/5 pin 16 amps socket point on independent board complete all as specified and as directed. Note: Chases cutting and making good to disturbed surfaces shall be measured and paid separately)
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landing, steps, cills, sunshades sheleves, lintels, etc and cutting chases for concealed water tubing or concealed conduict wiring etc and making good cutting not exc 10 cm grith complete all as specified and directed.
Supply and fix switch piano flush button 5/6 Amp single pole, one way complete all as specified and as directed.
Supply and fix socket outlet 5 Pin, 5/6 Amps flush type complete all as specified and as directed.
Supply and fix Switch socket combination 5 Pin, 5/6 Amp flush type complete all as specified and as directed.
Supply and fix switch socket combination 5 Pin 15/16 Amp flush type with complete all as specified and as directed.
Supply and fixing switch flush type, 6 Amps, single pole, two way complete all as specified as directed
Supply and fix lamp holder insulated body with back plate for angle/batten fittings complete all as specified and directed.
Supply and fix ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and directed.
Supply and fix bell push, flush type 6 Amps complete all as specified and directed.
Supply and fix electronic fan regulator stepped type flush type AC 240 volt complete all as specified and as directed.
Supply and fix in replacement call bell Ding Dong, AC, 230V single pole complete all as specified as directed.
Supply and fix lamp holder PVC polycarbonate type with cord grip cap sutiable for pendant fittings complete all as specified and as directed.
Supply & fix Modular switch, one way, 6 Amp, 1 module complete all as specified and directed.
Supply & fix Modular switch, one way, 16 Amp, 1 module complete all as specified and directed.
Supply & fix Modular switch 2 way, 6A, 1 Module complete all as specified and directed.
Supply & fix Modular Bell push 6A,1 Module complete all as specified and directed.
Supply & fix Modular socket, 6A-2/3 pin combined 2 Module complete all as specified and directed.
Supply & fix Modular socket, 6A/16A-2/3 pin combined 2 Module complete all as specified and directed.
Supply & fix Modular fan steep regulator, 120 watt, 2 module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 1 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 2 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 3 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 4 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 6 Module complete all as specified and directed.
Supply and fix Modular white cover plate with frame- 8 Module complete all as specified and directed.
Material and labour for sub-main wiring (surface type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductor of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC casing caping including taking down old sub main wiring with casing caping complete all as specified and directed. (Note:Two run of 4.0 sqmm copper conductor cable, one run of 4.0 sqmm earth continuity cable and one run of PVC casing capping shall measured as one unit).
Material and labour for sub-main wiring (surface type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductors of size 6.0 Sq mm and one run of 6.0 Sqmm copper conductor as continuity earth wire,drawn through and including PVC casing caping including taking down old sub main wiring with casing caping all as specified and as directed. (Note:Two run of 6.0 sqmm copper conductor cable, one run of 6.0 sqmm earth continuity cable and one run of PVC casing capping shall measured as one unit).
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated,unsheathed,FRLS single core,multistranded copper conductors of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (Note:Two run of 4.0 sqmm copper conductor cable, one run of 4.0 sqmm earth continuity cable and one run of PVC conduit shall measured as one unit). (ii)Cost of cutting of wall, if any, for housing of GI box and also making good the disturbed surfaces are deemed to be included in unit rate.
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated,unsheathed,FRLS single core,multistranded copper conductors of size 6.0 Sq mm and one run of 6.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i):Two run of 6.0 sqmm and one run of 6.0 sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC conduit shall measured as one unit). (ii)Cost of cutting of wall, if any, for housing of GI box and also making good the disturbed surfaces are deemed to be included in unit rate.
Material and labour for sub-main wiring (Surface type) with two run of PVC insulated,unsheathed,FRLS single core,multistranded copper conductors of size 10.0 Sqmm and one run of 10.0 Sqmm copper conductor as continuity earth wire,drawn through and including PVC Casing Caping (medium grade) of adequate size with fittings and accessories as required at site all and taking down old sub main wiring with conduit as specified and as directed. (Note:Two run of 10.0 sqmm copper conductor cable, one run of 10.0 sqmm earth continuity cable and one run of PVC conduit shall measured as one unit). (ii)Cost of cutting of wall, if any, for housing of GI box and also making good the disturbed surfaces are deemed to be included in unit rate.
Supply and fix in repair powder coated sheet metal enclosure (in concealed) single pole & neutral for DBs (Double door) 4 way, 240 V with 200 amps rated busbar DIN channel, neutral link & earth link superline complete all as specified as directed.
All as per item No 155 here in above but for 8 way SPN DB complete all as specified as directed.
All as per item No 155 here in above but for 12 way SPN DB complete all as specified as directed.
Supply and fix in repair vertical TPN DB with MCCB incomer of 4 way in double door suitable for four pole MCCB (63A/100 A)as incomer including MCCB+12 modules incoming and outgoing make good of damaged surface/wall including re-connection with existing earth wire to DB all as specified and as directed. Note:- MCCB shall be measured and paid separately.
Supply and fix MCCB triple pole & neutral 40-100 amps,,16 KA, with all incoming / outgoing connections suitable for fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified as directed.
Supply and fix MCB single pole & neutral / Double Pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed.
Supply and fix in repair MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified as directed
Supply and fix in repair GI wire 4.0 mm as earth continuity conductor complete all as specified and as directed.
Supply and fix in repair GI pipe 15 mm bore (dia), light grade for protection of earth electrode complete all as specified and directed.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified as directed.
All as per item no 165 above but using copper plate 60x60cmx3.15mm thick electrode and 20x3mm copper strip as earthing lead complete all as specified as directed.
Supply and fix in replacement Copper Strip size 20mm X 3mm (Taking out GI Wire) as earth continuity conductor with saddles and fixing screws etc complete all as specified and as directed.
Supplying & fixing LED tube light fitting, 1 x 18 watt bipin holders, connector block etc. complete with and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted twin core cable ,and fixing the light fitting to walls / roof complete all as specified & directed.
Supply and fix LED light fitting mirror type high output diffuser 2 ft ,10 watt, 220 volt AC decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and as directed.
Supply and fix round shape 6 watt, 220 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, LED lamp sutiable for roof ceiling including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and as directed.
Supply and fix round shape 12 watt, 220 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, LED lamp sutiable for roof ceiling including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm 40 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fix in repair LED light fitting, 1x10/1x9 W bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix in repair LED lamp (B22 Base type) of 1x7 W after taking down the old unserviceable CFL/GLS lamp complete all as specified and as directed.
Supply and fixing in repair flame proof 2x16 W/ 20W LED tube light fixture with tube recommended for Gas / Vapor of IIA & IIB and Zone 1 and IP65 Protection complete all as specified and as directed.
Supply and fix in repair contactor with digital type timer switch for street light for 24 hrs operation including connection with existing serviceable DB and programming complete all as specified and as directed.
Supply and fixing in repair LED light fitting 25/35 watt energy saving versatile pressure die-cast aluminium building security luminaire with suitable GI bracket complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and as directed.
Supply and fixing in repair LED light fitting 45 watt energy saving versatile pressure die-cast aluminium building security luminaire with suitable GI bracket complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and as directed.
All as per item no 178 here above but for 60 Watt complete all as specified and as directed.
Supply and fix LED post top lantern with post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including 20 Watt LED lamp with all accessories and fixing in existing post complete all as specified and as directed.
Supply & Fix in repair modular type power unit 25 amps complete with 4 module plate, starter plug and socket . Make-Crabtree (Sapphire) /Havells / C&S /Bajaj / Havells
Repair to E/M appliance(Geyser) Taking down Geysers of any make/ model / type / capacity after disconnecting all electrical and water supply line for repair/ replacement of parts and components, making the geyser in fully working condition, refixing in old position after repair/replacement complete all as specified and as directed. Note :- (i) Spares used in replacements will be measured and paid seperately as supply only). (ii) The labour element involved in replacing the spare is deemed to be included in the unit rate quoted. (ii) The unit rate shall also be deemed to include for minor spares required for the functional utility of the appliance.
Supply only Apparatus assembly plate ( 8/9 hole) for Geyser of 25 Ltrs / 50 Ltrs capacity (as per existing sample) complete all as specified and directed.
Supply only Thermostat straight stem type complete all as specified and directed.
Supply only Heating Element 1500 watt suitable for Geyser of 25/50 Ltrs capacity Triangular/Round type complete all as specified and directed.
Supply only Indicating (Red/Green) lamp LED type (square/Round) button type for Geyser of 25/50 Ltrs capacity complete all as specified and directed.
Supplyonly PVC flexible cold water inlet pipe 15 mm dia 600 mm long complete all as specified and directed.
All as per item No.187 above but Hot water pipe ( Inlet wiremess type) complete all as specified and as directed.
Supply only cast copper alloy, CP, stop cock, ISI marked, 15mm bore complete all as specified and as directed. .
Supply only round type 3 core incoming copper cable of size 2.5 sqmm for 25/50 Ltrs capacity Geyser complete all as specified and as directed.
Repair to fan: Taking down carefully Ceiling Fans of any make, model and capacity from their existing places for replacement of bush, bearing, Capacitor, servicing i. e. lubricating / Greasing and for rewinding/ painting by dismantling the same and keep the blades, canopy, splitpin and other parts and components in safe custody and hanging / fitting on it's previous position after repair/rewinding/painting/replacement of spares etc complete all as specified and directed. Note:- i) The unit rate quoted is deemed to include for the labour element involved in replacing the spares as mentioned herein below. (ii) The spares replaced shall be measured and paid as supply only items herein below. (iii) The spares shall suit the exisiting makes of fans or as per existing make of spares, as approved by the GE. (iv) Rewinding and painting shall be measured and paid separately. Existing makes :- Bajaj, Khaitan, Usha, Himadri
All as per item No. 191 above but Exhaust Fans complete all as specified and as directed.
All as per item No. 191 above but Air Circulators wall mounted Fan complete all as specified and as directed.
All as per item No. 191 above but floor mounted pedestal fan complete all as specified and as directed.
Supply only GM Bush for ceiling fan 1200/ 1400 mm sweep/ Exhaust Fan 230/ 300/ 350/ 450 mm sweep/or any type fancomplete all as specified and as directed.
Supply only Ball bearing (cat No. 6201) for ceiling Fan/Exhaust Fan / or any type fan complete all as specified and as directed.
All as per item No. 196 here-in-before but cat No. 6202 complete all as specified and as directed.
All as per item No. 196 here-in-before but cat No. 6203 complete all as specified and as directed.
Supply only capacitor 2.5 mfd, 220 volts complete all as specified and as directed. Make:Tipcon / Universal / Sarda / Usha. / C&S).
All as per item No. 199 here-in-before but 3.0/4.0 mfd complete all as specified and as directed.
Supply and fix in replacement of louver shutter for 300 mm sweep exhaust fan, of existing make, made of MS sheet folded type complete all as specified and as directed.
All as per item No 201 here-in-before but for 450 mm sweep exhaust fan complete all as specified and as directed.
Material and labour for painting by spraying with synthetic enamel paint to Ceiling Fans / Exhaust Fans/ Air Circulators wall mounted Fans/Floor mounted pedestal Fans including Blades/Down rods/ Canopy/Stand, Casing/ Cage and all accessories after preparation of surfce including thoroughly rubbing /cleaning old rusted spot complete all as specified and as directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for Rewinding of ceiling fans armature of 1200 mm /1400 mm sweep of any make & Model with replacing the burnt out winding by new super enameled high grade copper wire of existing gauge and number of turns and all insulating materials including heat vernishing and testing complete all as specified and as directed.
All as per item No. 204 here-in-before but for exhaust fan 230mm/ 300mm sweep, single phase, 230 volts complete all as specified and as directed.
All as per item No. 204 here-in-before but for exhaust fan 450 mm sweep, three phase, 230 volts complete all as specified and as directed.
Supply and fix in repair fan blades for exhaust fan of 300 mm sweep as per existing make and type complete all as specified and as directed.
All as per item No. 207 here-in-before but for exhaust fan of 450 mm sweep complete all as specified and as directed.
Material and labour for lathe work for worn out spindle of ceilling fan /Exhaust Fan/Air Circulators/Wall mounting Fan of any sweep , make & Model with replacing the worn out spindle by new one of existing size and materials including testing for free motion of fans complete all as specified and as directed.
S&F in repair of incoming twin core copper flexible wire ( not more than 45cm) of size 14/0.0076 from ceiling rose to ceiling fan / exhaust fans complete all as specified and as directed.
Supply and fix in repair 3 pin plug top 6 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and as directed.
Supply and fix in repair 5 pin plug top 16 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and as directed.
Supply and fix in repair 2.5 mfd fan capacitor, 220V complete all as specified and as directed.
Supply and fix 50mm bore galvanised pipe 'medium grade’ for fixing ceiling fan including housing/ fixing of GI pipe in wall and also making good the disturbed surfaces complete including taking down old unserviceable pipe complete all as specified and directed. Note :(i)Cost of cutting of wall, if any, for housing/ fixing of GI pipe and also making good the disturbed surfaces are deemed to be included in unit rate.
Supply and fix Wall mounting fan 400 mm sweep, 230V, AC 50 Hz, 1360 RPM with blade set, 3 speed with oscillation and tilt mechanism and mounting accessories complete all as specified and as directed.
Supply and fix Pedestral fan 400 mm sweep, metal body, 3 speed operation, 100W, 2200 RPM , 230V, AC 50 Hz, 1 with oscillation and tilt mechanism and mounting accessories complete all as specified and as directed.
Supply and fix exhaust fan 300 mm sweep, metal body, 230V, AC 50 Hz, copper winding and mounting accessories complete all as specified and as directed.
Supply and fix exhaust fan 250 mm sweep, metal body, 230V, AC 50 Hz, copper winding and mounting accessories all as specified and directed.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutters 250 mm sweep, 230V, AC 50 Hz, copper winding and mounting accessories all as specified and directed.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutters 300 mm sweep, 230V, AC 50 Hz, copper winding and mounting accessories all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix mild steel rod including fabrication of hook ,size as required at site for hanging the ceiling fan including taking down old unserviceable old rod complete all as specified and as directed.
RADHA ENTERPRISE
MAZUMDER & CO
KAY BEE ASSOCIATES
M/S SHEKHAR TRADING CORPORATION
CHOWDHURY SMALL INDUSTRIES
RBS Builders
RUNJEN CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .