Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹67.1 L+₹5.2 L (8.37%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹80.9 L+₹19.0 L (30.7%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | Rejected-Technical INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | - | Rejected-Technical Two class below required class | |
| 5 | Rejected-Technical PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | - | Rejected-Technical Two class below required class |
Tender Value
₹61.5 L
EMD Value
₹1.2 L
Closing Date
14 Mar 2022, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS VALSURA JAMNAGAR 361150
SPECIAL REPAIR OF ELECTRIC WIRE ITEMS OF VIDYALAYA BUILDING AT INS VALSURA JAMNAGAR
2022_MES_509995_1
8574
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹1,000
GE I NAVY JAMNAGAR
₹1.2 L
Yes
4 Aug 2022
23 Feb 2022
16 Mar 2022
23 Feb 2022
14 Mar 2022
8 Mar 2022
23 Feb 2022 - 7 Mar 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for PCC 1:3:6, type C2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified.
M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping including necessary formwork complete all as specified.
Material and labour for dry river sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover, class LV type flat size 250mm x 150mm x 40mm for protection of underground cable in trenches complete all as specified. Make: Mehtab tiles / Ultra tiles / Sirex / Scorpio/ Sukhi tiles or any ISI marked tiles as approved by GE.
S&F framed bracket of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary, gusset plates, rivering etc. as per sample complete all as dircted..
Taking, down carefully copper/ aluminium point wiring (Light, Fan, socket or power) complete (fittings such as switches, celling roses, pendants, regulators, sockets, DB's) etc all as specified and directed.
Taking down carefully unserviceable Main switch and DB's including wooden board and removing from site including making good disturbed surfaces of wall all as complete as specified and as directed.
Dismantling and taking down fluorescent tube light single /double of any wattage & size, security light fittings for repair or replacement of burnt / wornout accessories etc complete all as directed.
M&L for concealed type point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting / chasing in any type of wall & making good the disturbed surface with plastering in cement mortar 1:4 thickness as ordered ,applying 2 mm thick Birla putty & finally painting the finished surface with two coats of painting as per exixiting one to match with the existing surface complete all as directed.
All as per item No. 12 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No.12 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 12 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F in repair Modular switch 1 way 6 Amps,1 module all as specified and direced.
S&F in repair Modular switch 1 way 16 Amps,1 module all as specified and direced.
S&F in repair Modular Socket 6A -2/3 pin combinaed 2 Module all as specified and directed.
S&F in repair Modular Socket 16A -2/3 pin combinaed 2 Module all as specified and directed.
S&F in repair Ceiling rose surface bakelite White/ Ivory/ Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F in repair Bell Ding Dong AC 230 Volts, single pole/ Multi Music type.
S&F in repair Modular Bell push 6 Amps, 1 module complete all as specified and directed.
S&F 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaguar Cat No. LGLZ01X020XC CCT : 6500 or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F 10 Watt wall mounted 2 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaguar Cat No. LGLZ01X010XC CCT : 6500 or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F 36 W LED indoor surface mounted LED light fitting, made from extruded aluminium housing, 2 ft X 2 ft lighting fixture flat light dissipater. The CCT(K) should be between 3000 to 6000 fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaguar Cat No. LSVR01S036XC CCT : 6000K or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F LED security/ street light 45 Watt in aluminium pressure die cast housing with touch glass cover (IP 66 protection) and impact resistance fitting and fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaguar Cat No. LSRT01S045XC CCT : 5700K or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F 120W LED street light fitting, new generation energy saving and environmental friendly long life source with toughened glass having IP 66 protection and impact resistance fitting and fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaguar Cat No. LSRT01S120XC CCT : 5700K or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F 32 mm bore GI pipe and suitable bend GI bracket for street light fitting holded by saddles etc. include all accessories to fix on corner of the building.
S&F 200 W LED flood light fittings with high pressure die cast housing with indivisual lens and toughened glass cover having IP 66 protection, powder coated CCT(k) 5700, fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as directed. Make: Jaguar Model No - Ledstar Floodlight(>110Lm/W) Cat No. LFLDSLM200XC CCT : 5700K or equivalent of Bajaj / Crompton Greaves / Philips / Wipro/ Havells.
S&F45W LED Post Top light fitting made with die cast housing with decorative clear opal acrylic diffuser and IP 65 protection and fixe as per manufacturer's instruction complete all as directed. Make: Bajaj Cat No. BGCT W4 LED WW or equivalent in Havells / Phillips/ Crompton / Schreder/ Wipro.
S&F 1400 mm sweep, ceiling fan with all accessories 230 V, SP with provision of 3 core cable from ceiling rose to fan complete in fan hook including taking down old fan complete all as specified. Make: Bajaj Model No. Kessle 50 ISI 1400 mm White CF or equivalent in Havells/Khaitan/ Usha/ Orient) Note: Old ceiling fan shall be deposited to KV School Valsura Store Incharge , necessary RV obtained from Store Incharge shall be submitted to Engineer-in-charge before submission of RAR .
S&F in repair step type electronic fan regulator modular type 100W, 1 Module, fixing on existing phenolic laminated sheet as required complete. Make: Legrand Cat No. 6730 27 or equivalent in ABB/ Indo Asian/ Havells/ Crabtree
S&F in repair 600mm long, 20mm bore GI pipe down rod suitable for hanging ceiling fan and white colour with all necessary fitting complete all as specified.
M&L for making arrangements for Fan hook of standard type as per SSR specification including cutting RCC slabs to the required depth upto existing MS bars tie up with new one and making good disturbed surfaces complete all as specified and as directed.
S&F 300mm sweep metal Body Exhaust Fans AC single phase 230/ 240 V of size including making provision of hole of requisite size in round shape in existing wall of any type and grounting the foundation bolts of required size and making good the disturbed surfaced with PCC 1:2:4 and CM 1:6 as required duly painted with new paint matching with existing shape complete all as directed. Make: Bajaj Model No. Supreme Plus 300 mm 900 rpm Ind EX Fan or equivalent in Khetan/ Havells/ Orient.
S&F Single pole sheet metal enclosure with a two pin and earth plug and socket complete 240V with one single pole MCB 20 amp all as specified and directed by Engr-in-Charge
S&F 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of diamensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate diamensions 200x200x12 mm, foundation bolt size 4 nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with MCB SP 6 A-1 No., MCB TP 32 A 10 kA-01 No., Neutral connector - 63 A Cap-01 No. complete all as specified and as directed. Make: Bajaj BOP-6030 or equivalent in Philips / Havells / Wipro. Note: Earth work and PCC foundation shall be measured separately
S&F in repairs three phase AC Static Electronic energy meter of accuracy class 1.0, 3X240V, 50Hz with backlit LCD display of rating 10-60A (Measures & Displays kWh, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication port & Display in absence power including (CT) complete all as directed. Make: HPL Electric & Power Ltd Cat No. TPPB1521130000ME01 or equivalent of MECO, SECURE, L&T (Note: Old meter shall be deposited at AGE E/M Store yard.)
Supply, installation, commissioning and testing of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 2000 Event Storage with Real Time Clock, Upto 192 grouping facility, Pre Alarm Action, Programmable detector sensitivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test. 40 X 4 Characters LCD display 2 numbers of loop card and 200 devices in any combination per loop. Day / Night Mode facility. USB 2.0 Interface for PC connectivity. Rs. 485.00 Communication facility for Network / Repeater / MODBUS / BACnet. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220VAC + 10% -15%, 60 / 50 Hz. Standby Power 24V D.C (2 No’s of 12V, 40 Ah (Max), Built in for 12Ah) Sealed Lead acid battery Operating Condition Operating Temperature 0 - 49° C / 32-120° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C / 90 ±3° F including taking down old unserviceable Panel complete all as specified and as directed.
Supply commissioning and testing of Smoke detector Operating Voltage Range: 9 to 32 VDC Volts Non-polarized Standby Current: ≤100µA @ 24 VDC, Maximum Alarm Current (LED on): ≤55mA @ 24 VDC, Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing, Operating Temperature Range: 14°F to 120°F (-10°C to 49°C), Adjustable Sensitivity: 1-2.5%/FT, Height: 2.2 (55 mm) installed in Base including taking down old unserviceable smoke detector complete all as specified and as directed.
Supply, commissioning and testing of explosive proof manual call point.
Supply, commissioning and testing of file alarm sounders/ sirens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 50 db to 120 db measured at 1.5 m with sound output variation of +5 db 500 mtrs range complete all as specified and directed.
M&L for copper cable FRLS 1100 volts grade PVC sheathed of size 3 core 1.5 Sqmm including suitable size PVC conduit and acessories suitable of Fire/ Smoke detecting system sensor to panel.
S&F MCCB DB's VTPN (Vertical DB) type double door in wall/ nitch when MCCB's to be used four pole and neutral, 8 way, 415 Volt with rated busbar, suitable for flush mounting and surface mounting with 250 Amps copper busbar for each pahse and 2 neutral bar, 2 Earth bar and cable ties for cable management, fully insulated busbar and shrouded Neutral bar, improved pan assembly for ease of intallation, Prefitted masking sheet, Reversible door for IP 43 and 54 DB's with provision for DPX3 250 Amp MCCB as incomer and TPN/ SPN/ DP/ SP outgoing IP 54 protection complete all as specified and as directed by Engineer-in-Charge. Make: Legrand Cat Part No 5077 59 Modules No. DPX3 250+24 or equivalent in ABB / Siemens/ Indo Asian/ Standard.
S&F MCCB DB's VTPN (Vertical DB) type double door in wall/ nitch when MCCB's to be used four pole and neutral, 8 way, 415 Volt with rated busbar, suitable for flush mounting and surface mounting with 160 Amps copper busbar for each pahse and 2 neutral bar, 2 Earth bar and cable ties for cable management, fully insulated busbar and shrouded Neutral bar, improved pan assembly for ease of intallation, Prefitted masking sheet, Reversible door for IP 43 and 54 DB's with provision for DPX3 160 Amp MCCB as incomer and TPN/ SPN/ DP/ SP outgoing IP 54 protection complete all as specified and as directed by Engineer-in-Charge. Make: Legrand Cat Part No 5077 47 Modules No. DPX 3 160+24 or equivalent in ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T. Note for Item Nos.44 & 45: MCCB shall be measured and paid separately under relevent item.
S&F in repair MCCB 250 Amp, 415 V with adjustable thermal and magnetic setting of breaing capacity 24 kA complete all as specified and directed. Make:Legrand Cat Part No. 4202 09 or equivalent in ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T.
S&F in repair MCCB 160 Amp, 415 V with adjustable thermal and magnetic setting of breaing capacity 24 kA complete all as specified and directed. Make:Legrand Cat Part No. 4200 47 or equivalent in ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T.
S&F sheet metal enclosures for DB's double door in wall / nitch when MCB's to be used Triple pole and neutral, 4 way, 415 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 8 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 4 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 2 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repair RCBO four pole 415 V, 50 Hz, 100 Ma, 63 Amp complete all as specified and directed. Make: Legrand Cat No. 4118 83 or equivalent of ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T.
S&F in repair RCBO double pole 240 V, 50 Hz, 100 Ma, 40 Amp complete all as specified and directed. Make: Legrand Cat No. 4118 57 or equivalent of ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T.
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 92 to 4085 95 of ABB / Siemens/ Indo Asian/ Standard/ Havells/ L&T.
S&F in repairs 20mm PVC conduit duly concealed only for LAN/ telephone cable.
M&L for 2 sqmm 2 core flat/ Co-axial copper, flexible cable including concealed with suitable size PVC conduit with accessories of PA system.
Taking down existing submain wiring and M&L for concealed type submain wiring with two runs of single core 6 Sqmm PVC insulated unsheathed multi-stranded copper conductor cable drawing in and including PVC rigid medium grade conduit concealed of suitable size complete including provision of 6 Sq mm copper unsheathed cable PVC insulated as earthwire connected to earth doll inclusive of al tees, bends, elbows,reducers including cutting / chasing in any type of wall & making good the disturbed surface with plastering in cement mortar 1:4 thickness as ordered ,applying 2 mm thick Birla putty & finally painting the finished surface with two coats of painting as per exixiting one to match with the existing surface complete all as directed. etc all as specified and directed. Note: 3 runs of 6 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length.
Taking down existing submain wiring and M&L for concealed type submain wiring with two runs of single core 4 Sqmm PVC insulated unsheathed multi-stranded copper conductor cable drawing in and including PVC rigid medium grade conduit concealed of suitable size complete including provision of 4 Sq mm copper unsheathed cable PVC insulated as earthwire connected to earth doll inclusive of al tees, bends, elbows,reducers including cutting / chasing in any type of wall & making good the disturbed surface with plastering in cement mortar 1:4 thickness as ordered ,applying 2 mm thick Birla putty & finally painting the finished surface with two coats of painting as per exixiting one to match with the existing surface complete all as directed.etc all as specified and directed. Note: 3 runs of 4 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length.
Taking up or down exingting cable and Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 185 Sqmm 3.5 core making necessary connection & testing on completion all as directed.
All as per item No. 59 here in above, but for cross-sectional area 70 Sqmm, 3.5 Core.
All as per item No. 59 here in above, but for cross-sectional area 35 Sqmm, 3.5 Core.
All as per item No. 59 here in above, but for cross-sectional area 16 Sqmm, 4 Core.
All as per item No. 59 here in above, but for cross-sectional area 10 Sqmm, 4 Core.
All as per item No. 59 here in above, but for cross-sectional area 6 Sqmm, 4 Core.
S&F in repairs junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole/wall with MS clamp 25x5 mm and necessary painting to MS clamp complete all as directed.
M&L for VTPN box fabricated from 2mm thick CRCA sheet double door type of size suitable for fixing VTPN box 8 way, 3 Nos. control and MCCB 3 Nos. complete with cable alley for incomming & outgoing cable with locking arrangement including LT danger notice plate complete. Note: MCCB and VTPN box shall be measured and paid separatly.
Supply and lay 20 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2, laid in trenches as cable protection with all fittings complete all as specified.
S&F 50 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete laid in trenches/ fixed on walls complete all as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
M&L earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 8 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing all as specified and as directed including testing on completion.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed by the Engineer-in-Charge.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation earthing etc. as required 25x4 mm dia galvanised iron strip complete all as specified and as directed by the Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .