Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Work Awarded to L1 Bidder |
| Sl No | Description | Qty | Unit | Tomco Engineering (P) Ltd. L1 |
|---|---|---|---|---|
| 1.00ANIMAL HOSPICE AND PALLIYATIVE CARE UNIT | ||||
| 1.00 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 252.23 | cum | 300 ₹75,669.90 |
| 1.00 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 1,867 | cum | 215 ₹4.0 L |
| 1.00 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 800 | cum | 109 ₹87,200 |
| 1.00 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 2,500 | sqm | 15 ₹37,500 |
| 1.00 | 2.28.1:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil | 1,600 | sqm | 29 ₹46,400 |
| 1.01 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 61.87 | cum | 7,978 ₹4.9 L |
| 1.01 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | 82.87 | cum | 8,391 ₹7.0 L |
| 1.01 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 36.6 | cum | 9,289 ₹3.4 L |
| 1.01 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 54.58 | cum | 8,037 ₹4.4 L |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
3 Oct 2025, 2:00 pmClosed
APCCF ETW
Office of the APCCF ETW Wing Forest HQ Thiruvananthapuram
KIIFB Projects - Construction of Animal Hospice Centre and Palliative Care Unit for Tigers
2025_FD_786367_2
KFD/SFDA/ETW3-136/25
Open Tender
Civil Works - Others
270 days
Forest HQ Thiruvananthapuram
As per Bid Document
11 documents required · 11 mandatory
₹5,900
Yes
₹50,000
Yes
14 Jan 2026
17 Sept 2025
4 Oct 2025
17 Sept 2025
3 Oct 2025
17 Sept 2025
Amount
ANIMAL HOSPICE AND PALLIYATIVE CARE UNIT
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.28.1:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
11.4:52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
16.70.1:Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
19.30.1.1:Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
24.2:Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
2.10.1.1:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soilPipes, cables etc, not exceeding 80 mm dia
50.18.7.3.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge 25 mm dia 12 Kgf/cm2 - Internal work - Exposed on wall
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
50.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.9.4.2:Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 6 Kgf/cm2
50.18.9.5.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
50.18.9.6.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
OD39635/2024-2025:Providing and fixing steel welded mesh of size 35x35 mm including iron frames etc complete as per the direction of Engineer-in- charge.<br
OD39636/2024-2025:Supplying and laying 40 mm HDPE pipe PE 100 (IS 4964/1995) including trenching and<br>refilling
PROVISION FOR PLANTING TREES, CREEPERS, PLANTS, LOG BENCHES FOR BIG CATS
OD39909/2024-2025:Suppling and planting terminalia or similar garden trees including digging, clearing surrounding of plants etc complete as per the direction of engineer- in -charge
OD39918/2024-2025:Supplying and planting creeper plants to grow on existing fencing including forming plant form for planting etc complete
30.2.15.1:Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete:With common burnt clay F.P.S. (non modular) bricks of class designation 5
30.2.57.3:Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Hedge plants (for 300 nos.=427.45/300)
OD1742/2025-2026:Tiger log bench
PROVISION FOR NEW OPEN WELL AND WATER SUPPLY
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
100.3.3.1:Earthwork in open well excavation (above water) for wells of diameter above 2.5m and up to 3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.2.1:15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)
100.3.3.3:Earthwork in open well excavation (above water) for wells of diameter above 2.5m and up to 3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.5m including neat banking.
100.3.3.4:Earthwork in open well excavation (above water) for wells of diameter above 2.5m and up to 3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.5m to 6.0m including neat banking.
50.18.7.3.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge 25 mm dia 12 Kgf/cm2 - Internal work - Exposed on wall
50.18.7.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall
OD1660/2025-2026:Supplying and fixing good quality PVC bibcock water tap including labor, carriage, fixing etc complete as directed by the engineer in charge
ELECTRICAL WORK
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD7/2025-2026:Supply and installation of 20W LED Flood light/focus light IP66 of reputed brand
OD9/2025-2026:Supplying and fixing Dust and vermin proof, 3 Phase Syntex Meter Board GS-MB-6535(size 760x450x260x) and to fix KSEB meters, fuse units, CT etc. as required including fixing it on wall, making good the damages colour washing etc. as required.
OD8/2025-2026:Supply and fixing 63A HRC fuse base with fuse link
OD10/2025-2026: Earthing with G.I. earth pipe 2.7 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD2/2025-2026:Supply, Conveyance, installation, testing and commissioning of 48/50W LED Flood light, output greater than 105 lumen/W, 4000-6000K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 kV and Aluminum pressure die-cast, Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duty wired up for use on 230V AC supply. Driver compartment should be separately accessible for maintenance.
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD11/2025-2026:Supply, installation, testing and commissioning of 20W LED Tube Light fittings, giving connection with 3 core PVC insulated and sheathed round copper flexible wire to wall/ceiling, conforming to relevant ISS etc. complete as required.
OD6/2025-2026:Supply and Installation of Rust Resistant and Weather-Proof Bulk head light fixture with 9W LED lamp, IP 65 protection complete with all other accessories as required.
OD1430/2025-2026:SITC of LIGHTNING ARRESTER/ LIGHTNING DIVERTER with adequate earthing with adjustable diverter assembly for spark gaps
OD1429/2025-2026:SITC of EARTHING SYSTEM - WITH 8MM SS ROD OF 304 GRADES, WITH RETAINING MOISTURE MIXTURE FITTED TO 50*50*50 CM Pit
OD1428/2025-2026:SITC of STRAIN INSULATOR - POLYPROPYLENE / POLY CARBON capable of withstanding 16KV
OD1427/2025-2026:Fixing 50X50 mm ISI make GA or GP square pipe make of vertical raiser length of 4.60 M and horizontal post guard of length 1.2 m including galvanizing and fastener assembly
OD1426/2025-2026:SITC of Stainless-steel wire 1.5 mm 304 grade non resting quality for main line (Approx 17500Mtrs)
OD1425/2025-2026:SITC of Stainless steel 1.2 mm 304 grade non rusting quality for Earthing line and Middle Line (For Horizontal Line at Feet above the ground) (Approx 4500 Mtrs)
OD1424/2025-2026:Supply &amp; Laying of Stainless wire rope 1.5 mm dia 304 Grade non rusting for hanging line (13500 Mtrs)
OD1431/2025-2026:SITC of Bullets (connecters) - copper material or aluminum material or stainless-steel material having an inner core size of 2.5 mm Dia 2 cm length
OD1423/2025-2026:SITC of Bottom fixture with bush (adopter for 75 mm pipe into 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
OD1422/2025-2026:SITC of DIGITAL VOLTMETER (Minimum 10KV Capacity) for measuring fence line volt
OD1421/2025-2026:TOOL KIT Should contain: Wire tightener handle, Twisting tool, Pliers, Double ended spanner for clamp tightening
OD1420/2025-2026:Warning signs poly-ethylene plastic with statutory colors and signs
OD1419/2025-2026:Supply &amp; laying of LEAD OUT CABLE Must be double insulated withstanding 15 KV Voltage. Inner core wire must be hot dip galvanized. For under gate and base unit connection.
OD1418/2025-2026:Erection charges
EXTERNAL LIGHTING AND UG CABLE
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
PROVISION FOR CCTV SURVEILLANCE SYSTEM INCLUDING ALL ACCESSORIES
OD1360/2025-2026:Supply of 24-Port x Gigabit Ethernet RJ-45 Copper ports (10M/100M/1G) -1000BASE-T with 2 Gigabit SFP (fiber) ports (100M/1G) - 1000BASE-X with 193W POE power budget and 5 year Warranty. Make:- Netgear/Dlink/Equivalent
OD1361/2025-2026:Supply & Installation of 4 MP 15X zoom IR Network Speed Dome(IP66), Pan and tilt ability with 100m IR range, Support H.265+/H.265 video compression 120 dB WDR technology, 4.8 mm to 120 mm, 15× optical zoom, TVS 6000V Lightning Protection, Surge Protection and Voltage Transient Protection and Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, Object Removal Detection, Unattended Baggage Detection, Audio Exception Detection with metal housing with mounting accessory. Make:- HIKVISION/ Dahua / Equivalent
OD1362/2025-2026:Supply of 32CH 4HDD NETWORK VIDEO RECORDER, Supports Smart H.265+, H.265, Smart H.264+, H.264 and MJPEG decoding formats,Max. decoding capability: 32 × 1080p@30 fps or 32 × 2MP@30 fps., Max. 384 Mbps incoming/recording/outgoing bandwidth, Supports IP cameras with a resolution up to 32 MP, Supports AcuPick with up to 32 channels, Supports N+M cluster,iSCSI, AI by Recorder supports 2-channel face detection and recognition, up to 20 face databases and 20,000 face images; 4-channel perimeter protection; 8-channel SMD Plus, AI by Camera supports face detection and recognition, perimeter protection, SMD Plus, metadata, ANPR, stereo analysis, heat map, and people counting., Supports EPTZ, and one- click arming and disarming. With 5 year.Warranty. Make:-HIKVISION/ Dahua / Equivalent
OD1363/2025-2026:Supply and installation of Weatherproof IP65 3x3 PVC co box for fixing CCTV
OD1365/2025-2026:Supply and Installation of Un loaded patch panel – Cat 6 - 24 port with Mounting plate s display stickers etc. Make:- Dlink/Molex/Equivalent
OD1367/2025-2026:Supply of Cat 6 one Mtrs patch cord for rack side. Make:- Dlink/Molex/Equivalent
OD1369/2025-2026:Supply & Installation of HDMI Cable - 5 Mtrs HDMI MALE TO MALE 1.4V, 24AWG-26AWG Make: LTK/Honeywell/ Equivalent
OD1370/2025-2026:Supply and installation of Large Format Display with Diagonal Size 32, Type - Edge LED BLU, Resolution - 1920*1080 (Full HD), Pixel Pitch(mm) 0.360 x 0.360, Active Display Area(mm) 698.4(H) x 92.85(V), Brightness(Typ.) 400 nit, Contrast Ratio 5000:1, Viewing Angle(H/V) 178/178, Response Time(G- to-G) - 8ms (Typ.), Display Colors 16.7M(True Display) 1.07B (Ditherd 10bit), Color Gamut - 72%, Operation Hour - 24/7, Haze - 2%. With 3 year warranty. Make: Samsung/LG/Equivalent
OD1371/2025-2026:Supply and Commissioning of Aluminium cover for the bullet camera installed including all cost
OD1372/2025-2026:Supply, Installation, Testing and Commissioning of 4 TB Surveillance hard Disk compatible with the NVR. Make:- Seagate/WD or Eq
OD1373/2025-2026:Supply and installation of 1.25Gd SFP Module Single mode 1310 nm1000 Base LX/LC connector
OD1374/2025-2026:Supply and laying of Outdoor Cat 6 UTP Cable through existing conduits. Make: Molex/Equivalent
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD1386/2025-2026:Splicing Charges
OD1387/2025-2026:Supply and installation Base-Lx to 1000 Base-T PoE Media Converter
OD1388/2025-2026:Supply & laying of 6 core outdoor Unitube Single Sheathed Armored Type os2 Fiber Cable polyethylene (HDPE) outer sheathed; and embedded with two steel wires on the periphery. The cables are constructed with a UV stabilized PE jacket. The cable is anti-termite and anti-rodent with Tensile Strength Min: 1500N ,Crush Resistance Min: 3000N/10CM and Operating Temperature range : -40°C to +70°
OD1524/2025-2026:Supply & Installation of 4 MP IR IP Bullet Camera with 1/2.9" Progressive Scan CMOS, 120 dB WDR, 3D DNR, Built-in microphone for real-time audio security, Fixed focal lens 4 mm, IR upto 30m, Support Human and Vehicle Detection,H.265+/H.265/H.264+/H.264 video compression, PoE: IEEE 802.3af, IP67 protection
OD1525/2025-2026:Supply and Installation of CAT 6 Information outlet modules in Patch Panel. Make:- Dlink/Molex/Equivalent
OD1526/2025-2026:Supply & Installation of Wireless Key Board and Mouse Bundle with non- rechargable batteries.Make:- HP/Logitech/Equivalent
OD1527/2025-2026:Supply and installation of Bend Insensitive Fiber Optic Patch Cord LC-LC, Duplex, Single Mode, 3 meter with Durability: 500 insertions and Operating Temperature: -40°C to +85°C with LSZH Sheath
OD1529/2025-2026:Supply and installation of 9U- 600D Rack with NVR Tray with front lockable glass door, cooling fan, 4Way 5A PDU indian pin-1 no, 1U horizontal cable manager with cover 1 nos 1U shelf other mounting accessories with Hardware kit. Make:- Dlink/legrand/Equivalent
OD1540/2025-2026:Supply & Installation of Dome Camera with 2-MP 1/2.8" CMOS image sensor, low luminance,and high definition image. Outputs max. 2 MP (1920 × 1080)@25/30 fps. Support Triple Stream, H.265 codec, high compression rate, ultra-low bit rate, Built-in IR LED, and the max.illumination distance is 30 m, ROI, SMART H.264+/H.265+, flexible coding, applicable to various bandwidth and storage environments, Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking, applicable to various monitoring scenes, Intelligent monitoring: Intrusion, tripwire (the two functions support the classification and accurate detection of vehicle and human). Supports max. 256 G Micro SD card; built in MIC, 12 VDC/PoE power supply, easy for installation, IP67 and IK10 protection, SMD Plus. Make:- HIKVISION/ Dahua / Equivalent
PROVISION FOR HANGING SOLAR FENCE
OD1376/2025-2026:SITC of Supply and Installation of 12 volt 100AH Solar VRLA , SMF battery (EXIDE/AMARON or EQUIVALENT) with 3 years replacement warranty
OD1377/2025-2026:SITC of MODULAR STAND AND BOX FOR SOLAR PANEL, BATTERY & Fabrication, Supply and Installation of Module Stand and water proof Battery and equipment safety box with following specifications 50mm dia 2.75mtr long GI base pipe and connect L angle through pipe for fixing 1nos solar panel and providing dust, water and vermin proof pole/floor mounting cubicle type rack fabricated from 1.6mm/16swg CRCA sheet, and powder coated, hinged door,r rubber beedings and provision for energizer, charge controller and 1 nos of battery etc as required.
OD1378/2025-2026:SITC of SOLAR MODULE FOR HANGING FENCE - Providing Solar module Mono-PERC IEC 61215 With following specifications (1) 200watts 12 volt rating with minimum 10 years warranty against manufacturing defects of approved brand and (2) Solar Charge Controller with display 12v/24v to regulate the charging of the battery of approved brand
OD1379/2025-2026:SITC of ENERGIZER FOR HANGING FENCE - 12V ENERGIZER, 9.9KV output AC input 12V DC, Minimum 4 Jule (CPRI CERTIFIED, complying with all National & International safety standards) Switch to High, Medium and Low Power settings. Peek Output Voltage not more than 9.90KV O/P Energy to 4.5 Maximum Pulse duration 1.01~3.0m.sec, Pulse Interval 1.1~1.4 Sec
OD1382/2025-2026:SITC of GSM ALERT SYSTEM - With Fence Voltage Alarm and SMS Alert to Minimum 3 Mobile Number, Additional Relay contacts for remotely switch on Flood Light/ Siren/ CCTV/ Speakers etc through GSM Missed call
Bidder Name
Tomco Engineering (P) Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid