| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹34.7 L+₹8.1 L (30.6%)Rejected-Finance FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹36.0 L+₹9.4 L (35.5%)Rejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹36.8 L+₹10.2 L (38.4%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹37.6 L+₹11.0 L (41.6%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/MAINT OF LT OVER HEAD LINE, SERVICE CONNECTION AND LT UNDER GROUND CABLE UNDER GE CLEMENT TOWN
2021_MES_487310_1
GE/CLT/ Of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Clement Town
Class D Cat b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹80,000
Yes
11 Feb 2022
10 Nov 2021
8 Dec 2021
10 Nov 2021
6 Dec 2021
23 Nov 2021
90 days
Amount
Taking down or dismantling unserviceable ACSR conductor of any size from LT over head line by necessary disconnecting of conductor and removing etc complete all as specified and directed.
Dismantling of old unserviceable MS iron bracket and other frame work complete all as specified and directed. .
Taking down of unserviceable insulators any type and size from over head line complete all as specified and directed.
Dismanteling of GI earth strip / guard cradle wire from LT over head line by necessary disconnecting of wire and removing complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed.
Supply and laying , un-reinforced precast concrete cable cover ISI marked ,class LV,Type I,flat,size 250mmX150mmX40mm with breaking load capacity 200 KG complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection , one twin core cable flat or circular with solid conductor of size 10 Sqmm complete all as specified and directed.
Supply & laying cable XLPE insulated PVC sheathed, galvanised steel strip or wired armored. Electric power cable (heavy duty) 1100 V grade with stranderd aluminium conducter of size 10 Sqmm 2 core including lugs of suitable size on wall/ in trenches complete all as specified and directed.
Supply & laying cable XLPE insulated PVC sheathed, galvanised steel strip or wired armored. Electric power cable (heavy duty) 1100 V grade with stranderd aluminium conducter of size 10 Sqmm 4 core including lugs of suitable size on wall/ in trenches complete all as specified and directed.
All as per item No.11 above but 16 Sqmm 4.0 core and -ditto-.
All as per item No.11 above but 25 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 35 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 50 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 70 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 95 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 120 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 150 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 185 Sqmm 3.5 core and -ditto-.
All as per item No.11 above but 240 Sqmm 3.5 core and -ditto-.
Dismanteling of old unserviceable steel pole any type by breaking PCC and taken away from site complete all as specified and directed.
Supply, transportation, errecting & fixing in truely vertical position , steel tubular swaged pole over all height 9.0 Mtrs , type 410-SP-31 complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts washers and screws including painting two coats of aluminum paint over one coat of red-oxide primer and 3 Nos bands/straps 30cm wide with yellow paint from plinth block and numbering of pole with black paint 2.5 cm in height including one coat of tarring of pole on steel surface embedded in concrete complete all as specified and directed. (Note : Excavation/earth work, PCC in foundation/ plinth block and cable protection pipe shall be measured and paid for seperately under appropriate item of schedule 'A')
All as srl item No 5 here-in-before but exc 1.5mtr in depth beyond first 1.5m and -ditto-.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded broken stone aggrigate) as in coping of poles above grounding including necessary form work, complete all as specified and directed.
Material and labour for cement concrete (1:3:6) (40mm graded aggregate ) type C-2 for foundation of poles including necessary form work complete all as specified and directed.
S& F in replacement Automatic street light switch using Nature switch based on LUX level of nature light, three phase 8kw, contactor rating 25 Amps, MCB rating 32 Amp complete all as specified and directed.
S&F in replacement of junction box made from SMC/FRP sheet ready made of size 300 x 200 x 100 mm having 100A capacity for RYB and neutral with aluminium buster with 4 way connector fixed to pole/wall with MS clamp 25 x 5mm and nut bolts including following :- (a) MCB SP 6 Amp 10 KA 240 Volt with aluminium lugs -01 No complete all as specified and as directed.
Supply and fixing MCCB 125 Amps 4 Pole 25 KA adjustable type complete all as specified and directed.
Supply and fixing Bus bar chamber factory made, outdoor type made out of 3.15mm CRCA sheet of size 700x450x300 pedestal type with 200Amps rated aluminium bus bar TPN system & space for One No MCCB 125 Amps 4 Pole complete all as specified and directed.
M&L for earthing complate with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtr depth below groundlevel at any type of strata) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected by GI strip 25x4 mm as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 (using 20mm graded Crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm, 15mm thick plaster in (1:4) funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) reiforced with XPM and charcoal, dust and common salt all as shown in electrical plate No.3 of MES SSR Part -1 (2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15mm dia light grade GI pipe protection and watering pipe of GI 20mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and as directed. Note :- (i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid separately under relevant items.
Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of following size including all required fittings complete all as specified & directed.
for 50 mm dia
for 40 mm dia
for 80mm Dia
for 100mm Dia
Cutting the existing bituminuos road for passing of UG Cable in road crossing and making good the disturbed surface of road with PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) complete all as specified and directed.
Cutting, trimming and prunning of trees/tree branches of any girth upto 2.5 m all around existing LT over head lines / sourrounding street light and flood fitting including cleaning the area beneath the LT overhead lines and removing the debris from the site and depositing where complete all as specified and directed.
Supply and fixing ACSR aluminium conductor, steel reinforced of any size and type maintained standard sag including providing aluminium binding wire, aluminium jointing, jumper etc complete all as specified & directed.
S&F in replacement cable jointing kit 1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed.
S&F in replacement cable jointing kit 1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.
S&F in replacement cable jointing kit 1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 Sqmm, complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing Pin type procelain, Vitreous, White, brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut 100 mm height , 65 mm dia for 1100 volt grade complete all as specified and directed.
Supply and fixing Galvanised steel earth strip size 25x4 mm complete all as specified and directed.
Supply and fixing cable route indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick welding with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) block of size 300 x 300 x 400mm including one coat of synthetic enamel black paint over a coat of zinc chrome red oxide primer and writing letter with white paint showing size of cable, LT/HT complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Ansh Enterprises
BK CONSTRUCTION
Ravi Electrical
SEEMA ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .