Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC KIZHAKKE PARAVILA VEEDU RANDALUMMUKKU EZHUKONE P O | PATHANAMTHITTA | KERALA | 689694 | L1 | Accepted-AOC below PAC L1 | |
| 2 | L2₹14.4 L+₹19,680 (1.39%)Rejected-AOC | L2 | Rejected-AOC above PAC L2 |
| Sl No | Description | Qty | Unit | RAJAN N (MAHALEKSHMI CONSTRUCTIONS) L1 | AJIN R L2 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS | |||||
| 1.00 | 15.28.1
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the
material within 50 metres lead of :G.S. Sheet | 288.32 | sqm | 165 ₹47,572.8 Lowest | 165 ₹47,572.8 Lowest |
| 1.00 | 15.17.2
Dismantling steel work in single sections including dismembering and stacking
within 50 metes lead in:Channels, angles, tees and flats | 1,531.2 | kg | 2.37 ₹3,628.94 Lowest | 2.37 ₹3,628.94 Lowest |
| 1.00 | 50.2.25.1
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction
of site Engineer-in-charge | 49.68 | cum | 729 ₹36,216.72 Lowest | 729 ₹36,216.72 Lowest |
| 1.00 | 4.1.5
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3
coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm
nominal size derived from natural sources) | 15.68 | cum | 8,569 ₹1,34,370.49 Lowest | 8,569 ₹1,34,370.49 Lowest |
| 1.00 | 7.1.1
Random rubble masonry with hard stone in foundation and plinth including levelling
up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate
20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse
sand) | 3.58 | cum | 8,343 ₹29,892.97 Lowest | 8,343 ₹29,892.97 Lowest |
| 1.01 | 13.33.1
Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled
pointing | 30.06 | sqm | 400 ₹12,024 Lowest | 400 ₹12,024 Lowest |
| 1.01 | 5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers | 12 | sqm | 762 ₹9,144 Lowest | 762 ₹9,144 Lowest |
| 1.01 | 5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases up to floor five level excluding the cost of centering,
shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone
III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size
derived from natural sources). | 2.1 | cum | 13,442 ₹28,228.2 Lowest | 13,442 ₹28,228.2 Lowest |
| 1.01 | 5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more | 210.38 | kilogram | 112 ₹23,562.22 Lowest | 112 ₹23,562.22 Lowest |
Tender Value
₹14.2 L
EMD Value
₹35,572
Closing Date
24 Jan 2026, 3:00 pmClosed
Regional engineer
the office of the Kerala State Nirmithi Kendra,Kottarakkara,Kollam
This work consists of Construction of Dismantling of GS sheet,steel work in single section,Filling earth in treches,PCC,Random Rubble Masonry,Pointing,Centering and shuttering, Reinforced Concrete works ,Steel reinforcement ,Steel Work
2026_KSNK_828237_1
KSNK/TECH/KTR/CBCKP-160/2026
Open Tender
Civil Works - Buildings
Item Rate
30 days
Kochu Pampa Pathanamthitta
Refer NIT
6 documents required · 6 mandatory
₹2,500
₹35,572
Yes
3 Feb 2026
16 Jan 2026
27 Jan 2026
16 Jan 2026
24 Jan 2026
16 Jan 2026
16 Jan 2026 - 24 Jan 2026
CIVIL WORKS
15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
15.17.2 Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:Channels, angles, tees and flats
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.33.1 Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.10.1 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.2.1 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
OD288818/2025-2026 Providing and fixing 3mm thick or nearest size Aluminium Composite Panel (ACP) complete as per architectural drawings and including necessary screws ,riverts, etc as per the direction of Engineers -in-charge and also including charges of all materials ,conveyance ,fixing and all labour charges etc. complete OD288818/2025-2026 Providing and fixing 3mm thick or nearest size Aluminium Composite Panel (ACP) complete as per architectural drawings and including necessary screws ,riverts, etc as per the direction of Engineers -in-charge and also including charges of all materials ,conveyance ,fixing and all labour charges etc. complete OD288818/2025-2026 Providing and fixing 3mm thick or nearest size Aluminium Composite Panel (ACP) complete as per architectural drawings and including necessary screws ,riverts, etc as per the direction of Engineers -in-charge and also including charges of all materials ,conveyance ,fixing and all labour charges etc. complete
21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
11.46.2 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
13.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
ELECTRICAL WORKS
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
5.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.4.2 Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD290086/2025-2026 Supply, installation, testing and commissioning of wall mounted Three Phase 4 wire Energy meter with poly carbonate body having range of 10-63A, with enclosure made out of powder coated 16 SWG CRCA sheet suitable for fixing in surface/recess with 3 nos. of 63A HRC fuses,63A TPN isolator, neutral link, its inter connections etc. The enclosure shall have lockable door with glass window and all mounting accessories etc. complete as required (supply of energy meter is under KSEB scope)
OD290267/2025-2026 Supply Conveyance, installation, testing and commissioning of 30 W LED Top light output greaterthan 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8KV,and Aluminium pressure die-castPowder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,<br>RoHS compliant, duly wired up for use on 230 V AC supply.
OD292254/2025-2026 Supplying and fixing 30W LED High Bay Light ,Branded items - fixing, connecting, commissioning etc including all labour and material charges etc. complete in all respects as per the directions of Engineer-in charge.
OD292271/2025-2026 Exhaust fans in toilet and rest room. Including cabling/ conduits/ control switches/ sockets, including all Labour and Material charges etc. complete in all respects as per the directions of Engineer-In-Charge
OD292520/2025-2026 Supplying and fixing 20W LED Tube set (Approved Brands) and other accessories
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.72 MB
tendercondition.pdf
Tender Documents • 0.58 MB
epaymentform.pdf
Other Document • 0.01 MB
agreement.pdf
Additional Documents • 0.29 MB
BOQ_1390360.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .