| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC 49 53 7 13 1ST FLOOR SAMPADA GALAXY BS LAYOUT NEAR 4TH TOWN POLICE STATION VISAKHAPATNAM ANDHRA PRADESH 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹47.9 L+₹3.7 L (8.46%)Rejected-Finance DOOR NO 25 32 NAGARAPALEM ROAD MADHURAWADA VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹48.7 L+₹4.6 L (10.5%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST | |
| 4 | L4₹58.3 L+₹14.2 L (32.2%)Rejected-AOC FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST | |
| 5 | Rejected-Technical 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | - | Rejected-Technical not meeting the eligibility criteria |
Tender Value
₹55.0 L
EMD Value
₹1.1 L
Closing Date
9 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE No 2 Visakhapatnam
CWE No 2 Visakhapatnam Military Engineer Services Chief Engineer Complex Station Road Visakhapatnam 530004
REPAIR MAINTENANCE OF SPARES OF VCBs, RMUs, HT CABLES AND ALLIED WORKS AT TP AREA, NON TP AREA IN INS KALINGA AND NAD BHEEMUNIPATNAM, VISAKHAPATNAM
2022_MES_518551_3
82562
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE P Navy Kalinga
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE P Navy Kalinga
₹1.1 L
Yes
22 Sept 2022
18 Jul 2022
11 Aug 2022
18 Jul 2022
9 Aug 2022
26 Jul 2022
18 Jul 2022 - 25 Jul 2022
Amount
Supply and replace closing coil assembly 110 V DC to Schneider make 11 KV VCB and including necessary connection, testing complete all as specified and directed.
Supply and replace tripping coil 110 V DC to Schneider make 11KV VCB and including necessary connection, testing complete all as specified and directed.
Supply and replace spring charging universal motor with gear box 220 V AC for 630 A Schneider make 11 KV VCB and including necessary connection, testing complete all as specified and directed.
Supply and replace buffer (for opening spring) for 630 A Schneider make 11 KV VCB and including necessary connection, testing complete all as specified and directed.
Supply and replace buffer (for closing spring) for 630 A Schneider make 11 KV VCB and including necessary connection, testing complete all as specified and directed.
Supply and replace thermostat and space heater, 230 V AC for 11 KV HT VCB, cable chamber and including necessary connection, testing complete all as specified and directed.
Supply and replace single (Red-Blue) phase bus bar spout suitable for 630 A Schneider make 11 KV panel complete all as specified and directed.
Supply and replace single (Y) phase bus bar spout suitable for 630 A Schneider make 11 KV panel complete all as specified and directed.
Supply and replace drive beam suitable for 630A Schneider make 11 KV VCB complete all as specified and directed.
Supply and replace epoxy body suitable for 630A Schneider make 11 KV VCB complete all as specified and directed.
Supply and replace CT Spout suitable for 630A Schneider make 11 KV panel complete all as specified and directed.
Supply and replace CT's epoxy cast resin, with primary current 100A, 50A respectively as per feeder requirement, secondary current 1A or 5A, with dual core, dual ratio' protection core - Class 5P10, metering core - Class 1, 15 VA, suitable for Schneider make 11 KV panel complete all as specified and directed.
Supply and replace busbar support insulator suitable for Schneider make 11 KV panel with all necessary modifications at cable / busbar chambers complete all as specified and directed.
M&L setting of 3 phase IED of any type / Make from 11KV HT panel, cleaning the contacts, IED configuration, calibration & testing of all the measuring & protection devices viz., CTs, relays and meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set, checking of current transformer, rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & tripping coil. Adjustment / setting to lug and time multiplier settings of IED to achieve the discrimination in tripping, tune / synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc, proper programming of multifunctional meters and replacement of defective components & wiring with FRLSH multistrand PVC insulated copper conductor 1100 volts grade as per existing size of wire / type complete all as specified and directed.
Feeder wise Relay co-ordinations: M&L collecting necessary required data & peak load details from IED of any type / Make from 11KV HT panel and including transformer full load details during peak hours, relay setting calculations & co-ordination study, unit protection setting of transformers, feeder wise settings has to be furnished & report with firm recommendations to be submitted down stream power distribution (complete 11 KV system), overall co-ordination of time need to be achieved, adjustment / setting to plug and time multiplier settings of IED complete in all as specified and as directed.
Maintenance, servicing, buffing / cleaning, electroplating of copper busbar in busbar chamber of each VCB panel and including connecting bus bar from CT to main bus bar & spout, servicing of support insulator by clean cloth and hot air blower / vacuum cleaner, checking for any loose contact, refixing of all nuts & bolts by stainless steel , refixing all covers , replacement of defective bus spout complete all as specified and directed Note :- Required new components will be measured and paid separately under relevant items.
M&L applying Si-COAT 570 RTV Silicone high voltage Insulator coating solution using an sprayer on inside VCB panel along with busbars and re-connection of all existing cables, extended bus bars, testing complete all as specified and directed. Make:- CSL Silicones Inc. Canada or any E-in-Cs approved make
M&L attending rectification of faults in 11 KV VCB electrical circuit and including with all necessary accessories, tools & tackles for restoring the power supply with minimum shutdown time, complete all as specified and directed Note :- Supply only components will be measured and paid separately under relevant items.
M&L servicing of SF6 insulated outdoor type compact ring main unit HT 630 Amps, 11KV, 50 Hz consisting of any no of Incomers and outgoing to transformers with PT chamber and line CT and inluding by removing both the sources of power supply feeding through connected HT cable, switching on interlocking mechanism with earth switch carefully, checking its cable ends; removing the body cover of RMU, opening its covers, moving and fixed contacts, repair of moving / fixed parts, repair of its drive mechanism, moving & fixed contact, refixing its body covers, refixing the RMU with both ends of cables, necessary testing and charging the RMU complete all as specified and directed. Note: Each RMU of any no of incomers & outgoings will be measured as one unit
Supply and replace transformer HT terminal connector bushing boots suitable for existing distribution transformers of any make / size / type / capacity and including refixing of HT cable complete all as specified and directed.
Supply and replace monoplast putty for sealing HT cable entry side gaps in HT / LT panels, transformers cable entry box of suitable length / size and including refixing of HT cable side panel doors complete all as specified and directed.
Supply and replace expandable PU Foam Insulation sealant spray for sealing HT cable entry bottom side gaps to arrest rat / insects / reptiles entry to HT / LT panels and including refixing of HT cable side panel doors complete all as specified and directed.
Supply and replace 11KV grade heat shrinkable bus bar insulation sleeve 75 / 30 for HT panels complete all as specified and directed.
All as per Sl. Item No. 23 above but size 50 / 20 .
M&L cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint and including with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
All as per Sl. Item No. 25 above but 240 to 300 sqmm
M&L cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint and including with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
All as per Sl. Item No. 27 above but 240 to 300 sqmm
M&L cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint and including with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
All as per Sl. Item No. 29 above but 240 to 300 sqmm
Supply and replace 3 core 150 Sqmm, 11000 volts grade, XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor complete all as specified and directed. Note:- Earth work excavation, sand cushioning, cable protection etc, will be measured and paid separately under relevant items.
All as per Sl. Item No. 29 above but 3 core 185 Sqmm
All as per Sl. Item No. 29 above but 3.5 core 240 Sqmm
Excavation in trenches, not exc 1.5 m wide and not exc. 1.5 m in depth for laying of under ground cables etc, and getting out in hard / dense soil complete all as specified and directed.
All as per Sl. Item No. 34 above but in soft / loose soil.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Supply and replace reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 x l80 x 40 mm complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable etc, and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
M&L servicing of 11 KV / 0.433 KV transformer up to 500 KVA and including opening the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of LT / HT bush from the shell and replacement of burnt out LT / HT bush and gasket to avoid leakage of oil refilling back to existing oil into the transformer testing & commissioning complete all as specified and directed.
All as per Sl. Item No. 40 above but 750 KVA to 1000 KVA
Note for Sl. item Nos. 40 & 41 :- Supply only HT / LT bush will be measured and paid separately under relevant item.
Supply only of HT bushing and including metal parts and washer for any make / any model of plinth / pole mounted transformer 100 to 300 KVA capacity complete all as specified and directed.
All as per Sl. Item No. 42 above but 320 to 500 KVA capacity.
Supply only of LT bushing and including metal parts and washer for any make / any model of plinth / pole mounted transformer 100 to 300 KVA capacity complete all as specified and directed.
All as per Sl. Item No. 44 above but 320 to 500 KVA capacity.
Supply only LT rod / studs made of brass with nut and washers fittings etc, suitable for existing transformers for the following sizes complete all as specified and directed :-
100 to 500 KVA
750 to 1000 KVA
Supply only HT rod / studs made of brass with nut and washers fittings etc, suitable for existing transformers for the following sizes complete all as specified and directed :-
250 to 500 KVA
750 to 1000 KVA
Note for Sl. item Nos. 46 to 47 :- (i) The items wil be replaced during break down period period immediately as intimated by Engr-in-Charge (ii) Penaly for late response at Rs. 100 per item per day will be levied.
Supply only neoprene gasket of size 2 x 2 feet for pole mounted / plinth mounted transformer of any capacity complete all as specified and directed.
Supply only transformer oil to fill in plinth / pole mounted transformer of any capacity complete all as specified and directed.
M&L dehydration and filtration, cleaning of transformer oil in indoor/ outdoor type transformer at different locations of INS kalinga area by centrifusion / machine having minimum capacity 1000 to 30000 ltrs / hour to achieve dielectric strength not less than 50 KV and including testing oil before and after dehydration and topping up transformer oil complete all as specified and directed. Note:- Transformer oil for topping up will be measured and paid separately under relevent item.
Supply and replacement of existing size of ACSR jumper in HT/ LT over head line and including necesary binding wire, nuts & bolts, washers etc, complete all as specified and directed.
M&L spray painting of transformer, pole mounted / plinth mounted and including preparation of surfaces and applying synthetic enamel grey colour paint (conforming to IS 2032) for the foloowing capacities complete all as specified and directed :-
775 to 1000 KVA
550 to 750 KVA
360 to 500 KVA
315 to 350 KVA
200 to 250 KVA
150 to 160 KVA
63 to 100 KVA
LT / HT panels / OCBs / ACBs / RMUs of any size
Removal of metal from 2 pole structure yard and depositing a side for to filling of sand in yard and refilling the same duly cleaning from the foreign materials etc, after laying sand in layers complete all as specified and directed.
All as per Sl. Item No. 53 above but 4 pole structure.
Supply and spread 40 mm graded crushed stone aggregate in 2 / 4 pole structure yard complete all as specified and directed.
All as per Sl. Item No. 53 above but 20 mm
Supply and replace of lightning arresters expulsion type complete with all fittings tramission class, discharge capacity 65 Kilo amps suitable for 11000 volts complete all as specified and directed.
M&L detecting HT / LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre locator system HV surge generator fault pin point surge wave receiver cable identification instrument cable tracer for exact locations of under groung cable route complete al as specified and directed. Note : The rate quoted is deemed to be inclusive of rengal charges for T&P like entire cable fault locating Instrument, charges for operator and transport etc.
Supply and replace underground cable route indicator HT / LT made out of cast iron piece not less than 6 mm thick and including supported by 25 x 6 mm flat iron complete all as specified and directed.
Supply and replace danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colou and fixed with MS clamps, bols and nuts of approved size for HT 25 X 20 cm size complete all as specified and directed.
Supply and replace GOD air break switch for 2/4 pole structure (set of Three) horizontal / vertical type and including all fiting and fixture complete all as specified and directed.
Supply & replace silica jel for 100 KVA to 500 KVA transformer complete all as specified and directed.
Supply & replace breather assembly for 100 KVA to 500 KVA transformer
Jungle cleaning of sub station and including cutting the plants / bushes and trees not exc. 25 cm in girth up to authorised widths and thrown away the rubbish to a distance not exc. 50 m complete all as specified and directed.
P NARAYANA RAO
HARSHITHA INFRA
MURALI KRISHNA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .