Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC VISHNU NIVAS IRUMBA ARUVIKKARA PO TRIVANDRUM 695564 | THIRUVANANTHAPURAM | KERALA | 695564 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.8 L+₹10,242.33 (0.55%)Rejected-AOC BIG NO 7 104 MANAKKATTU VAYANAKOM NJAKKAL POST KRISHNAPURAM VIA OACHIRA PANCHAYAT ALAPPUZHA KOLLAM DISTRICT KERALA STATE PIN 690 533 | ALAPPUZHA | KOLLAM | KERALA | 690533 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹23.2 L+₹4.6 L (24.5%)Rejected-AOC 3 358 PALLICKAL KRISHNALAYAM PAKALKURI PO VARKALA THIRUVANANTHAPURAM KERALA 695604 | VARKALA | THIRUVANANTHAPURAM | KERALA | 695604 | L3 | Rejected-AOC Not Being L1 |
Tender Value
₹25.3 L
EMD Value
₹50,600
Closing Date
30 Dec 2022, 6:00 pmClosed
GE(I)(CG)KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507 BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
DAY TO DAY MAINTANANCE TO EXTERNAL WATER SUPPLY, ELECTRIC SUPPLY, DG SET, LIGHTING PROTECTION SYSTEM, SECURITY STREET LIGHTS, AIRCONDITIONER, CHLORINATOR ETC AT COAST GUARD STATION VIZHINJAM, TRIVANDRUM
2022_MES_567089_1
8845/CG/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Trivandrum
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I)(CG)KOCHI
₹50,600
Yes
27 Jan 2023
3 Dec 2022
6 Jan 2023
3 Dec 2022
30 Dec 2022
18 Dec 2022
3 Dec 2022 - 10 Dec 2022
Amount
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable (FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-.
(a ) one light point controlled by one switch 5 Amps
(b ) one fan point point controlled by one switch 5 Amps
(c) One 3 pin socket outlet 5 Amps on Independent board
(d ) One 3 pin socket outlet 5 Amps on same board
( e) One bell point controlled by one bell push
All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FR) including 4 sq mm PVC copper conductor used as earth wire for power point on independent board for One 3 pin socket outlet, 15 Amps.
Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix Socket outlet 2 in 1, 3pin 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix electronic fan regulator, 450W 250V stepped type, flush type complete all as specified and as directed.
Supply and fix Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge. Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid(Complaint register and decket slip to be provided by contractor) . (b) The spares required for the rectification of fault shall be measured under items 12 to 35. (c) 05 s of complain shall be measured as one Job.
Supply only Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only Switch Socket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only Bell push 5 Amps one way complete all as specified and directed.
Supply only Electronic fan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed.
Supply only Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fitting complete all as specified and directed.
Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
Supply only Modular switch, one way, 16Amps complete all as specified and directed.
Supply only Modular switch, two way, 6 Amps complete all as specified and directed.
Supply only Modular socket outlet, 5 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular fan regulator 230 volts, step type, 120 watt complete all as specified and directed.
Supply only Modular Bell push, 6 Amps complete all as specified and directed.
Supply only Modular Switch Socket Combination 16 Amps 6 pin complete all as specified and directed.
Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.
Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.
Supply only LED tube light batten 20 watt, 240 volts complete all as specified and directed. Make: CELS Cat part No CLLC-TBLP-20 or equivalent in Havells/Philips/Crompton Greaves.
Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: CELS Cat part No CLLC-LP-10 or equivalent in Philips/Bajaj/Surya.
Supply only MCB single pole & neutral 240 volt C curve 10 KA 40 Amps capacity IP 20 transparent lebel holder fully insulated safety shutters complete including suitable size copper lugs complete all as specified and directed.
All as per ser item No 32 above but MCB TPN 415 volt C curve 10 KA 40 Amps capacity complete all as specified and directed.
All as per ser item No 32 here-in-before but MCB single pole, 6 to 32 Amp 240 volt B curve 10 KA complete all as specified and directed.
Supply only energy efficient LED building security light Fitting 25 Watts on existing backets including connection with twin coe flexible PVC 0.5 Sqmm cable complete all as secified and as directed. Make:Philips Model No.BRP022 LED 20CW MR S1 PSU GR or Havells Cat Part No LHETBXU7PA6S020 or Wipro Cat No.LR02-291-XXX-57-XX.
Material and labour for Sub main wiring using two runs of single core PVC insulated cable(FR) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 4 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed . NOTE: MCB shall be measured and paid separatelty.
All as per ser item No 38 above but SPN 4 way, double door 240 volts complete all as specified and directed .
All as per ser item No 38 above but SPN 8 way, double door 240 volts complete all as specified and directed .
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed.
Taking down fan of any type and size after disconnecting, depositing to store yard and Hanging/fixing only after repair/reconditioning fan of any type and size all as directed. NOTE: Repair and reconditioning of fan shall be measured and paid separately under Item Nos.43 to 46.
Collecting unserviceable ceiling fan 1200/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed. Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.42 above. (ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.49 to 56.
All as per item No 43 above but exhaust fan 250 mm sweep
All as per item No 43 above but exhaust fan 300 mm sweep
All as per item No 43 above but wall fan 450 mm sweep
Material and Labour for Scraping down old paint of ceiling fan of any size 1200/1400 mm sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying sand paper painting the ceiling fan by means spray gun/brush with synthetic enamel white paint complete all as specified and directed.
Material and Labour for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
Supply only Gun metal bush for ceiling fan complete all as specified and directed.
Supply only Shackle type rubber reel,'U' clamps, bolts,split pin & washer complete all as specified and directed.
Supply only Canopy top/bottom suitable for 20mm dia rod complete all as specified and directed.
Supply only Down rod 300mm long of size 20mm dia ISI marked complete all as specified and directed.
Supply only Fan blades suitable for 1200mm sweep fan make & type complete all as specified and as directed .
Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make complete all as specified and as directed .
Supply and fixing in repairs Exhaust fan blade (three leaves) of 450mm sweep complete as per sample of the following sizes complete all as specified and as directed .
All as per item No 57 above but for 300mm sweep
Supply and fixing in repairs Wall mounting fan blade 400 mm sweep (three leaves) and make suitable for fixing and as per sample of existing fan complete all as specified and directed.
Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and type all complete all as specified and as directed.
Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per sample complete all as specified and as directed.
All as per item No 61 above but for 250mm sweep.
Supply and fix in repairs LED recess suitable for false ceiling 2 ft X2 ft, 40 watts , 240 volts AC supply complete all as specified and directed. Make : Cat part No CLLC-RMLSS-40 of CELS or or Equivalent in Crompton Greaves / Havells.
Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed . Note: Spare parts shall be measured and paid separately under relevant item.
Shifting of split type AC existing location/from MES yard to the new location by taking it after pumping filling and making good the opening of old location with cement mortor, applying treatment of wall to matching with existing colour and finish and making opening holes on brick wall at new location and gap well finish with cement mortor, applying finish to wall to match with existing colour of the adjacent surface , installation and commissioning with replacement of insulation of suction and discharge line complete all as specified and directed.
Shifting of water cooler electric driven single phase any make and capacity from MES yard/existing location by taking it after disconnection of electric and water line and refixing the same in any other new location including water and electric reconnection complete all as specified and as directed
Supply and fix in repairs Printed Circuit Board suitable for 1.5/2TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB shall be of existing manufacturer as compatible with the AC.
Disconnecting, dismantling and taking out existing burnt out compressor from window type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from window type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40 to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs complete all as specified and directed. Make : LG/ Voltas/ Samsung
Supply and fix in repairs AC blower fan motor for AC suitable for 1.5 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
Supply and fix in repairs AC blower fan motor for AC suitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
Supply and fix in repairs Thermostat switch for water cooler/Window AC complete all as specified and directed.
Supply and fix in repairs Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and directed.
Supply and fix in repairs Capacitor 45 MFD complete all as specified and directed.
Supply and fix in repairs Capacitor 50 MFD complete all as specified and directed.
Supply and fix in repairs insulation Nytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs insulation Nytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs Copper tube 5/8 inch size as per site requirement of approved make all as spd and directed .
Supply and fix in repairs Copper tube 1/4 inch size of approved make all as specified and directed .
Supply and fix in repairs blower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 1.5 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 2 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 1.5TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
Supply and fix in repair Bracket stand suitable for 1.5/2 TR Capacity Split type AC including Fastners, etc. Complete all as specified and directed.
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applinces complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material / soil to a distance n.exc 50m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
Material and labour for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection and taking out broken bricks complete all as specified laid perpendicular to cable as per directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
All as per item No 93 above but of size 25 Sqmm 3.5 core.
All as per item No 93 above but of size 16 Sqmm 3.5 core.
All as per item No 93 above but of size 6 Sqmm 4 core.
Material and Labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 63 Amps, 10 KA breaking capacity fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Cat part No IHLASF0063 of Havells or Equivalent in L&T / Legrand.
All as per Item No 99 here-in-before but of capacity 100 Amps, 10 KA breaking capacity complete all as specified and directed Make: Cat part No IHLASDCF0100# of Havells or Equivalent in L&T / Legrand.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 160 Amps 25 KA breaking capacity fixed properly at directed location and connecting/testing complete all as directed. Make: Cat part No IHLANDCF0160# of Havells or Equivalent in L&T / Legrand.
All as per Item No 101 here-in-before but of capacity 200 Amps adjustable type, 25 KA breaking capacity. Make: Cat part No IHLANDCF0200# of Havells or Equivalent in L&T / Legrand.
All as per Item No 101 here-in-before but of capacity 250 Amps, adjustable type, 36 KA breaking capacity. Make: Cat part No IHLLSEBF0250# of Havells or Equivalent in L&T / Legrand.
All as per Item No 101 here-in-before but of capacity 400 Amps, adjustable type, 50 KA breaking capacity. Make: Cat part No IHLLSEBF0400# of Havells or Equivalent in L&T / Legrand.
Supply and fixing shock treatment chart duly framed using 1st class hard wood frame size 25mmx15mm treated french polish, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with 5mm thick plain glass, the area of board 1.20 Square Metre complete all as specified and directed.
Supply and Fix in repairs drop out explusion fuse assembly with fuse carrier, triple pole for 11KV,current rating 100A outdoor type having tow nos post insulator mounted on MS channel for each pole completed all as specified and directed.
Supply and fix in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
Supply and fix in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
Supply and fix in repairs GOD Triple pole mechanically operated,mounted on insulator and steel frame wiht operating mechnism worked from ground level for current rating up to 200 Ams 11KV complete all as specified and directed.
Supply and fix in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 Kilo Amps suitable for 11000V supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed.
Dehydration / filtration of transformer oils of transformer/switch gears to achive die-electric strength not less than 40kv for 1 miniute at 4mm gap as per relevent IS using portable filteration plant including testing of oil for die electric strength before and after filtration complete all as specified and directed. Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electricity for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
Supply and topping up new transformer oil into conservator tank/body tank of transformer using portable filtration plant and directed. Note:- (i) The transformer oil for topping up shall be with di electric strength more than 40kv for 1 miniute at 4mm gap. (ii) Oil shall be supplied at site in sealed barrel.
Supply and fix in repairs breather assembly including filling silica gel inside breather assembly of transformer suitable for out door type transformer complete all as specified.
Taking down existing street light fittings and S & F new high power energy saving LED street light fitting to ensure uniform distribution with die cast aluminium IP65 body and 48 W capacity including suitable fixing accessories complete all as specified and directed. Make: Cat No. ENDURACITYLITEPLAT+SL48WLED757PASYBOPC of Havells or equivalent in Wipro/Philips.
Taking down existing unservicdable terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 no 4 way connector 415V 63 A made out of polycorbanate or bakelite and 1 no MCB of 6 A with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed. Make: Sintex/Hensel
Supply, fixing, laying & testing galvanised iron water tubing of following capacities, medium grade, ISI marked with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches/floor including taking out unserviceable pipe of following size complete all as specified and directed:-
(a) 25 mm dia
(b) 40 mm dia
Supply and fix in repair Gun metal globe or gate valve of following sizes with iron wheel head screwed both ends conforming to IS 778 of 84 for iron pipe of following size complete all as specified and directed:- Make- Zoloto/Bir/Prakash.
(a) 25 mm dia
(b) 40 mm dia
(c) 50 mm dia
(d) 20 mm dia
Supply and fix in repairs CI Foot Valve, of following sizes flanged / Screwed with GM working parts as per IS - 4038 with nuts bolts and gaskets etc of following size complete all as specified and directed:-
(a) 50 mm dia
(b) 80 mm dia
Dismantling, Cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 5.0 HP complete all as specified and directed.
Material and labour for servicing of pump sets including replacement of Ball bearing, mechanical seal and greasing etc for the pump set capacity 5 HP complete all as specified and directed.
Supply and fix 3-layer PP-R polypropylene random copolymer pipes 50mm bore SDR 7.4 UV stabilished and anti microbial welded having thermal stability for hot & cold water including all PP R plain brass threaded fittings duly insulated with glass wool and aluminium cladding, jointed fixed complete in position (wall, ceiling & floor) including taking out unserviceable pipe complete all as specified and as directed.
All as per Ser item No 121 here-in-before but 40mm bore pipe.
Supply and fixing of PP-R Gate valves (brass insert) as per requirement of the site in PP-R pipe line of size 50 mm bore, ISI Marked, complete with necessary arrangements for fixing complete all as specified and directed.
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore complete all as specified and as directed.
All as per Ser item No 124 here-in-before but 25mm bore pipe.
Material and Labour for cleaning underground sump of 50000 Ltrs capacity by draining/ pumping out complete water from sump, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the sump, flushing out , washing of inner surface using lime and bleaching powder and clean water with the help of pump or drain out as required, applying a coat of white wash for all surfaces of the UG sump from inside, painting and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
Supply only Liquid sodium hypo chlorite solution grade-I as per IS - 11673 complete all as specified and directed.
Disconnecting existing overhead PVC water tank not exceeding 500 Litre capacity and Cleaning water tank with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etc through drain pipe or by manually all as specified and directed by Engineer-in-Charge (Tank shall be cleaned quarterly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and reconnecting and refixing in the same position after cleaning and testing for leakages of service tanks complete all as specified and directed.
All as per Ser item No 128 here-in-before but 750 Litre capacity.
All as per Ser item No 128 here-in-before but 1000 Litre capacity.
Material and Labour for cleaning of static water tank of 50000 Litre capacity by draining/pumping out complete water from the tank, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the tank, flushing out with bleaching powder, washing of inner surface using lime and clean water with the help of pump or drain out as required, applying a coat of white wash to all concrete surfaces of the tank from inside, painting of all metal parts and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
Dismantling, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 7.5 HP complete all as specified and directed.
Dismantling, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 1 HP complete all as specified and directed.
Material and Labour for general servicing of Electrical Driven main pump of 7.5 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland, packing, capacitors, terminal blocks etc complete all as specified and as directed.
Material and Labour for general servicing of Electrical Driven main pump of 1.0 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland, packing, capacitors, terminal blocks etc complete all as specified and as directed.
Periodical maintenance / servicing of diesel Gen set of 200 KVA capacityt DG set kirloskar at ICGS Jetty Vizhinjam for smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc for the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed. Engine Servicing /Gen overhauling :- (a) Checking the lubricant oil, topping up & changing filters if required (b) Checking the lubricant level and replacing if required (c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required (d) Checking/adjusting of sensers / controls of the Engine (e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc (f) Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters (g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required (h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers (i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal (j) Cleaning of air filter assembly (k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc (l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance (n) Removing unserviceable spares and fixing of new spares including testing etc
Alternator Servicing :- (a) Checking lubricant in the bearings (b) Checking electrical excitation system and repairing if required (c) Checking alternator insulation values and tightning the electrical connections etc (d) Checking circuits of various connections (e) Cleaning the slip rings/brushes etc (f ) Removing unserviceable spares and fixing of new spares including testing etc AMF Panel Servicing :- (a) AMF Panel shall be maintained for good operation with the existing components. Any components found defective will be renewed and paid under relevant item of schedule. (b) Removing US spares and fixing of new spares including testing etc Notes: (i) Spares, lubricant, coolant etc required for engine, main alternator & AMF panel will be measured and paid seperately. (ii) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted. Note: 1. DHPP (N) required at the time of mainteance/testing will be issued by MES. 2. Labour charges for dismantling/taking down and replacement/fixing new parts as and when required. 3. Spare required shall be measured and paid separately.
All as perItem No.136 above but 62.5 KVA DG set Kirloskar Location at ICGS Vizhinjam.
Supply and fix in repairs AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 125 -250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as specified and as directed. Make : Kirloskar / Cummins/Crompton Greaves.
Supply only lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed.
All as perItem No.139 above but 200 KVA DG set.
Supply only fuel filter element with 'O' ring as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
All as perItem No.141 above but 200 KVA DG set.
Supply only Air filter element inner and outer as required at site with 'O' ring as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
All as perItem No.143 above but 200 KVA DG set.
Supply only Governor control cable inner and outer for the 15 to 250 KVA cap/make gen set complete all as specified and as directed.
Supply only Solenoled shut off valve assembly complete suitable to operate with 12/24 volts DC complete all as specified and as directed.
Supply only Lube oil pressure sensor for Engine complete all as specified and as directed.
Supply only Ammeter 0-100 Amps complete all as specified and as directed.
Supply only Speedo meter cable including outer and inner cable complete all as specified and as directed.
Supply only Push button switch complete all as specified and as directed.
Supply only Ignition switch heavy duty with keys complete all as specified and as directed.
Supply only AMF relay and replacement of micropocessor 12V/24 complete all as specified and directed.
Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset of capacity 62.5 KVA to 250 KVA complete all as specified and as directed.
Supply only 'V' Belts/pump 'V' belts dynamo 'V' belts for following:- (a) 62.5 KVA DG set
(b) 200 KVA DG set
Supply only Flexible over flow pipe steel armoured/braided flexible with suitable end sockets of size 15 mm dia of suitable length complete all as specified and as directed.
Supply only lub oil SAE 15 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling complete all as specified and as directed. Make : Castrol/Power Supreme
Supply only distilled water to be filled in batteries complete all as specified and as directed.
Supply only coolant suitable for Diesel generating sets complete all as specified and as directed. Make: Castrol/HP/IOC
Supply and fix in repairs 400 A contactor 4 pole complete all as specified and as directed.
Taking down existing self motor of capacity 62.5 KVA to 200 KVA and servcing including replacment of unserviceable spare parts, Brush, holder, solonoid switch, armature bush, filed coil complete all as specified and directed.
Dismatling and removing fuel injection pump (FIP) of capacity 62.5 KVA to 200 KVA and taking out it to authorised workshop and replacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge.
Repairs to dynamo / alternator including removing from position remove the burnt out armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as directed.
Supply and fix in repairs radiator hose of any capacity complete all as specified and as directed.
Supply and fix in repairs fule hose set nylon type of any capacity complete all as specified and as directed.
Supply and fix in repairs radiator fan belt of any capacity complete all as specified and as directed.
Supply and fix in repairs valve door packing of any capacity complete all as specified and as directed.
Supply and fix in repairs turbo cooler rubber hose of any capacity complete all as specified and as directed.
Supply and fix in repairs radiator mounting set of any size complete all as specified and as directed.
Supply and fix in repairs oil drain hose set complete all as specified and as directed.
Supply and fix in repairs control unit for DG set of any capacity complete all as specified and as directed.
Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
Repairs to 24 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
All as per item No 172 above but of 12 V battery charging alternator.
Repairs to 12/24V self starter by removing, dismantling and taking it to authorised workshop and replacing unserviceable Armature including field coil tapping re-fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge.
Supply and fix in repair complete Dry cell tubular type 12 V / 110- 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixing as required at site to the concerned DG Set all as directed by engineer-in-charge. Make : EXIDE Model EL Plus or equivalent in LUMINOUS/AMRON
Painting of the following DG set after preparing the external surface apply one coat of spray painting by superior quality synthetic enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed:- (a) 200 KVA capacity installed at Jetty ICGS Vizhinjam
(b) 62.5 KVA capacity DG set at ICGS Vizhinjam
Note:- (a) Contractors representative / engineer shall report to concerned JE E/M in charge of AGE E/M office at fore noon and after noon to collect routine/urgent works related to internal electric supply till completion of work. The work shall be attended by the contractor immediately. The contractor shall ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screwes, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P items to his trades man. All routne / urgent job slip will be repaired and got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine / urgent work, the contractor shall be liable to pay the penalty as described in penalty caluse given here as under. (b) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than eight hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 8 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 8 hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the Engineer-in-charge. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 200/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding. (c) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Supply and fix Aluminium Air termination rod 12 mm dia single pointed 300mm long along with base plate welded at bottom of termination rod, of size 10 cm long fabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners (wooden block) complete all as specified and as directed.
Fixing only in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed.
Fixing only in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
Supply and fix in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed. complete all as specified and directed.
Supply and fix in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed. complete all as specified and directed.
Supply and fix in repairs Porcelain insulator of existing size for isolation of conductor from the building wall upto a height of G+2 floors by providing 15cm long fastners at every 16 cm distance in the wall complete all as specified and directed.
Schedule of Credit (Minus) Rs. 1,06,633.00.00 NOTE: Bidder shall insert credit amount of Rs. 1,06,633.00 as rate in Green field under Col-5.
STAR ENGINEERING ENTERPRISES
M/s VJ ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .