Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹80.5 L+₹76,425.88 (0.96%)Rejected-Finance SHOP NO 102 A ONE COMPLEX K V ROAD VILLAGE TOWN JAMNAGAR CITY JAMNAGAR JAMNAGAR GUJARAT 361001 INDIA | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not the lowest bid | |
| 3 | L3₹80.9 L+₹1.2 L (1.44%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bid | |
| 4 | L4₹82.9 L+₹3.2 L (3.95%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance Not the lowest bid | |
| 5 | L5₹83.6 L+₹3.8 L (4.78%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bid |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
30 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jamnagar
CWE (AF) Jamnagar Air Force station Jamnagar-361003
STRENGTHENING OF THE RAMP AND ASSOCIATED WORK OF CERTAIN UNITS AT AF STN JAMNAGAR
2021_MES_479257_1
81102/E8
Open Tender
Civil Works
Item Rate
270 days
Jamnagar
Class C and above and category a (i)
7 documents required · 7 mandatory
₹1,000
Yes
GE (AF) No 1 Jamnagar
₹1.6 L
Yes
23 Nov 2021
4 Oct 2021
1 Nov 2021
4 Oct 2021
30 Oct 2021
18 Oct 2021
6 Oct 2021 - 12 Oct 2021
60 days
Amount
Demolition of cement concrete of any description and in any position exc 15 cm thickness below or above ground level, including removal of debris to a distance exc 1.5 Km but exc 5 Km complete all as specified and as directed.
Excavating over areas not exc.1.5 m deep in any type of soil and getting out (excavation to be carried out on sunken portion of existing distrubed road and where soil accumulated) complete all as specified and as directed
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or or for shafts, walls, manholes, laying cables, pipes etc not exc 10 Sqm on plan and getting out in soft loose soil complete all as specified and as directed.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in Hard dense soil complete all as specified and as directed.
Excavating in trenches not exc 1.5m wide and exc 1.5m but not exc 3.0m in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan & getting out in any type soil complete all as specified and as directed.
Returning filling in soft/ loose soil incl spreading, levelling, watering, and well ramming in layers complete all as specified and as directed.
Removing excavated material of soils not exc 50 mtr and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface in any type of soil complete all as specified and as directed
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for sand cushioning 25mm thick over PCC surfaces, spread rolled and consolidated to gradient and camber required complete all as specified and as directed.
M&L for sand cushioning 10 mm thick over DLC surfaces, spread complete all as specified and as directed.
M&L for Moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering approved earth filling by spreading leveling to make the required level etc complete all as specified and as directed. Note:- (i) Soil required for filling shall be brought out from out side MoD Land under his own arrangement of contractor. (ii) Soil shall be free from, bushes, shrubs and other vegetation, black cotton soil.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to outside MOD land complete all as specified and as directed.
M&L for Providing cement concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.
M&L for Providing cement concrete type C-2, 1:3:6 (Using 40 mm graded crusheed stone aggregate ) as in surface channels and drains complete all as specified and as directed.
M & L for PCC (1:3:6) Type C1 (using 20 mm graded stone aggregate ) in coping of including necessary form work finished fair and even surface without using extra cement including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L RCC M-30 design mix (Using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc complete all as specified and as directed.
M&L RCC M-30 design mix (Using 20 mm graded stone aggregate) as in columns, pillars piers, posts and struts etc complete all as specified and directed.
M&L RCC M-30 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and as directed.
Formwork (fair finished) to sides of pillars , posts, struts, piers, columns and stachions etc, complete all as specified and as directed.
S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less then 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
M&L Mild steel screw bolts (macine made ) with hexagonal or square headsat one end and screwed the other or screwed the other or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut, not exc 5 cm long and dia of neck 5 to 10 mm complete all as specified and as directed.
Supply only Chain link MS galvanised fencing conforming to IS 2721: 2003 including line wires of 4mm dia straining bolts, etc including provision of binding wire .
Fixing only chain link fencing including line wires, any mess, size and type to any type of standards, rails, straining bolt all as specified.
M&L for mild steel work as in posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary welding, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured) complete all as specified and as directed.
S&F Mild steel round bars 10mm dia and over as in strengthening bars for chain link fencing conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F Rolled mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc, including cleats, brackets, etc. complete GDE Fe 410-0 or Fe 310-O complete all as specified and as directed.
M&L Mild steel Framed work of ornamental and intricate design such as in door and gates, Framed & hung as gates, including pintle hinges, stops, hand made sliding bolts, etc with ends of bars shouldered and riveted, or forged into spikes ,framed guard bars complete all as specified and directed.
S&F Rolled mild steel Roof trusses (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe410-0 or Fe 310-O complete all as specified and as directed.
S& F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes for vertical post, purlins and rafter complete all as specified and as directed.
S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium frame work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed. including necessary removal of existing electrical fittings and re-fixing in position without disturbing existing connected fittings complete all as specified and as directed. Make : Everest or equivalent as approved by GE
Supply & Fixing 6 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with screws and standard fittings, fixtures and accessories complete all as specified and as per manufacturer's instructions.
M&L for polythene film black colour 150 micron laid in road over sand cushioning complete all as specified and as directed.
M & L for 25 mm thick cement concrete type B0 1:2:4 (using 12.5 mm graded aggregate) as in flooring complete all as specified and as directed.
M&L for light shed ultra charged vitrified coloured tiles 600mm x 600mm x 8 to 10 mm thick (square / rectangular) polished, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exc 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:6 over PCC block masonry wall surface, finished the surfaces even and smooth without using extra cement all as specified and as directed.
M & L for rendering 15 mm thick on concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement cement all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:4 (as second coat), over and including 10 mm thick rendering in cement mortar 1:6 (as first coat) on stone / PCC block masonry wall surface, including mixing liquid water proofing compound in second layer only as per manufacturer’s instructions, finished the surface even & smooth without using extra cement cement all as specified and as directed. Note:- WPC will be measured & paid separately
Supply only integral water proofing chemical @ 200 ml/bag of cement complete all as specified and as directed. Make : Fosroc, Dr. Fixit or equivalent approved by GE.
M&L for 100 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base complete all as specified and as directed.
M&L for Cutting channels, grooves or rebates n exc 15 cm girth and trimming surfaces with or without reinfiorcement of concrete surfaces and block / stone masonry etc,including filling of PCC as a fillet on sheet complete all as specified and as directed.
Cutting holes in to existing walls built in CM or cement lime mortar & stone/concrete walls built in cement mortar for inserting holdfasts & making good dismantled portion in CM(1:3) or PCC(1:2:4) Type B-1 as required complete all as specified and as directed.
M&L for machine cut Granite stone ( in black colour ) of any size as approved by Engineer-in-charge of 18- 20 mm thick, in vertical / horizontal surfaces laid over cement screed base and jointed with black cement slurry with pigment to match the shade of granite incl grinding and polishing complete all as specified and directed.
M&L for rounding to edges stone slab/ kota stone/ granite etc such as in cooking platform, slab and any other similar situation all as directed by engineer in charge.
M&L Chequered cement concrete tiles with grey cement and pigment 30cm x 30cm thickness 20 to 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed be in CM 1:6 complete all as specified and as directed.
S&F 20 to 25 mm thick Machine cut, both side polished kota stone slab fixed as in shelves or partition under kitchen platform, fixed with cement mortar 1:4 complete all as specified and as directed.
M&L for Cement concrete work in pavements/hard standing of fluxtural strength 35 Kg/Sqcm in field using 400 Kg of cement/Cum thickness of concrete 25 cm thick or less or more including steel shuttering to concrete and finishing surface of concrete roads pavement by plate vibrator, floater when concrete is green etc complete all as specified and as directed. Note:- (i) All joints shall be measured & paid seperately under respective item of this schedule. (ii) Deduction for expansion joint shall be made in computing concrete qunatity.
Finishing surface of concrete roads pavement by floater, plate vibrator, brooming when the concrete is green complete all as specified and as directed.
Forming construction joints 30mm deep x 10mm wide fileld with sealing compound Grade 'A' complete all as specified and as directed.
Forming contraction joints(Dummy) 30mm deep x 10mm wide fileld with sealing compound Grade 'A' complete all as specified and as directed..
Forming 20mm thick expansion joint for 200mm thickness of concrete slab filled with preformed Compressive filler board HD-100 and top 30mm primed and sealed with sealing compound grade 'A' and provided with 20mm dia, MS dowel bars 50cm long (25cm in each slab) with ferrules, spaced at 300mm centres including boring formwork and performed filler for dowels complete all as specified and as directed.
M & L for forming fair finished drain or channel 50 CM in girth in CM concrete using extra cement incl form moulds complete all as specified and as directed.
S&F Anodised aluminium window & ventilator shutters powder coating of any colour (Thickness of powder coating not less than 50 micron), fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc,complete all as specified and as directed.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing in aluminium ventilator square n exc 0.5 sq.m in each pane, complete all as specified and as directed.
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron approve colour) three track window (two shutters glazed & one shutter wire gauge) with frame, glazed with 4mm thick tinted glass and. wire gauge with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including rubber bead, joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below and as directed :- (a) Frame (top & side) section shall of size 92.00x31.75x1.50mm (section No 20831). (b) Frame (bottom) section shall of size 92.00x31.75x1.50mm (section No 20832). (c) Top & side Member of shutter section shall be size 18.00x40.00x1.55mm (section No. 20738). (d) Shutter interlock section shall be of size 18.00x40.00x1.45mm (section No. 20737) (e) Bottom Member of shutter section shall be of size 18.00x40.00x1.55mm(section No. 20736). Note :- Section No give above are of make Jindal, Contractor may use similar section of other make as mentioned in Appx 'B' to PS.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5mm thick tinted glass and partly panelled with 9mm thick prelaminated particle board with both side decorative laminated including rubber bead, joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200mm size etc all as specified below and as directed. (a) Frame (top & side) section shall of size 101.60x44.75x2.4mm (section No 14021). (b) Vertical Memeber of shutter section shall be of size 85.00x44.45x2.00mm (section No 19560). (c) Top Memners of shutter section shall be of size 83.50x44.45x.2.0 mm (section No. 19581). (d) Lock rail (Middle member) of shutter section shall be of size 150.00x44.45x3.00 mm (section No. 19596). (e) Bottom Member of shutter section shall be of size 150.00x44.45x3.10mm (section No. 19584). (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (section No. 19370). Note :- Section No give above are of make Jindal, Contractor may use similar section of other make as mentioned in Appx 'B' to PS.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed.
S&F aluminium alloy door closer hydraulically regulated, universal type, suitable for door shutters of 1000 to 1200mm in width and weight 50kg and above and fixed in position to door frame complete all as specified and directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&l for SS steel wire rope of dia 10-12 mm gauge 97/19 as in stay assembly of pole having Height 12 mtr fixed in position on top of rcc ramp roof fixed with necessary suitable fastner / stays (casement) including drilling welding if necessary at site complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coats of Distemper oil emulsion over one coat of primer, after application of cement base wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying 2 coat of weather proof exterior emulsion paint in camouflage pattern (Apex Ultima) by diluting of water (as per manufacturer direction). A gap of 24 hours should be given between two coats, over a coat of primer on plastered/unplastered surface should be allowed to cure completely such as surfaces applying one coat of exterior wall primer (X2) by thinning a litre of primer with one Ltr of water allow the primer coat for four hours including cleaning and ensure that the surface to be painted is free from any loose paint, complete all as specified and directed.
M&L for Applying two coats of Distemper oil emulsion, white or tinted on old wall surface including preparation of surface complete all as specified and as directed.
M/L for open crack in V Groove with sutable grinder and pouring CONBEXTRA EP 10M ( Low Viscous Epoxy) with injection or gravity until saturation to top level and surface preparation for application of Nitoband AR Standard with brush or roller and application of polymer modified mortar M45 grade Rendersoc SP 40 upto 15 mm thickness complete all as specified and as directed. Make : FOSROC
M&L painting to steel surfaces of any description over 10 cm width or girth incldprepration of or untreated surface, with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and fixing 100 mm dia heavy class GI pipe for lightening Arrestor fixing complete all as specified and directed.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC concealed Conduit 20 mm dia , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size for modular switch complete all as specified and as directed. Note:- Cutting chaise wherever required for concealed wiring will be measured & paid separately.
All as per item No 73.00 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch complete all as specified and as directed.
All as per item No 73.00 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch complete all as specified and as directed.
All as per item No 73.00 above but point wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified and as directed.
M&L modular Switch, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M & L for modular socket white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete.
M & L for modular Switch, white polycarbonate body, 16A- 230 V, including connecting complete.
M & L for modular Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, indicator based including connecting complete.
M & L for Ceiling rose 3 pin flush type 6 Amps, 240 volts AC ISI marked.
Supply and fixing white cover plate with frame 6 to 8 module complete. Make : Legrand/C&S Electric/Havells
Supply and fixing white cover plate with frame 2 to 4 module complete Make : Legrand/C&S Electric/Havells
Supply and fixing Modular metal Flush box 1/2 to 4 module complete. Make : Legrand/C&S Electric/Havells
Supply and fixing Modular metal Flush box 6 to 8 module complete Make : Legrand/C&S Electric/Havells
M&L Sub main wiring using 3 phase four wire PVC insulated FRLS cable 4 sqmm copper conductor multi stranded drawn through in and including Non metallic PVC casing caping of med gde in wall / ceiling with all accessories and 4 sqmm copper conductor insulated cable using as earth wire and drawing into concealed PVC conduit all as specified and directed by Engg-in-Charge. (Note: Four runs of 4 sqmm copper cable & two run of 4 sqmm copper cable in and including not less than 25 mm PVC conduit will be measured as one unit.)
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 2.5 Sqmm drawn through in and including Non metallic PVC casing caping of med gde in wall / ceiling with all accessories with 1.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly Note: Two runs of 2.5 sqmm copper cable and one run of 2.5 sqmm cable incl 25mm PVC conduit will be measured as one RM.
S&F Distribution board made out of sheet metal powder coated, factory made, enclousure double door type TPN 4 way vertical type with 200 (Amps rated copper bus bar, neutral bar, earth bar, TP 43 protection including provision of 1 nos incomer MCCB 63 Amps, triple pole and neutral, 415V, 16 KA breaking capacity fixing of DB flush to wall surface complete all as specified and directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
S & F MCCB 63 Amps, 16 KA TPN fixed in DB/Panel box complete all as specified and as directed. Make :- Havells/C&S/L&T
S & F MCCB 32 Amps, 16 KA TPN fixed in DB/Panel box complete all as specified and as directed. Make :- Havells/C&S/L&T
Supply and Fix MCB’s single pole of 6 to 32 Amps capacity, fixed in sheet metal board complete including connection complete all as specified and directed.
Supply and Fixing MCB’s single pole & neutral, 6 to 32 Amps capacity, fixed in sheet metal board complete including connecting complete all as specified and directed.
Supply and fixing wall mounted fan 400 mm sweep, 230 V 50 Hz, with all connected accessories, fixed as per manufacturer's instruction and connecting complete all as specified as directed. Make: Havells/Crompton/Bajaj or equivalent of Make mention in Appx B
S&F energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed . Make Havells Cat no LHEWEBP7IN1W018 or equivalent of make mentioned in Appx 'B'
S&F Energy efficient recessed mounted 36 watt LED luminaire suitable for 600 x 600mm grid ceiling alongwith flat diffuser alongwith constant current electronic driver all as specified and directed. Make :- Havells Cat No LCTLRN-36-FD-CDL or equivalent of make mentioned in Appx 'B'
S & F LED Building security light fitting 30 watt, High efficiency IP-65 protection, consisting of electronic driver circuits, high quality transmittance lens, powder coated die cast Aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed alongwith suitable size of GI brackets and connecting complete all as specified and directed.
S & F LED Flood light fitting 95-100 watt, system efficiency not less than 115 lumens/watt, IP 65 protection consisting of high/low voltage cut off maintenance free isolated electronic driver circuits, low THD PMMA grade high quality. Transmittance lens, epoxy powder coated Die cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on bracket & connecting, complete all as specified and directed.
S & F LED Flood light fitting 60 watt, system efficiency not less than 115 lumens/watt, IP 65 protection consisting of high/low voltage cut off maintenance free isolated electronic driver circuits, low THD PMMA grade high quality. Transmittance lens, epoxy powder coated Die cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws connecting all as specified and directed. Note : Quoted rate include the fallowing:- (i) GI pipe( Medium Grade) 40 mm bore of length 3 Mtr (ii) Grouting of GI pipe with suitable size of clamps along with PCC (1:3:6) type C2 of size 300x300x300 mm hight at the bottom of the GI Pipe. (iii) Suitable size of clamps for mountings flood light fitting on the top of GI Pipe.
Supply and fixing Exhaust fan 450 mm sweep, metallic type, single phase, 230 V 50 Hz, with all connected accessories, fixed as per manufacture's instruction and connecting including cutting of hole and plastering complete all as directed. Make: Havells Model Turbo Force or equivalent of Make mention in Appx 'B'.
S & F pole mounted junction box ( Street light boxes) sliding type ( Door fits to base by means of sliding) for 3 phase 4 wire lighting system, moulded in FRP including provision of 1 Nos MCB 10 Amps and busbar insulator- 4 Nos with nut & bolts with fixing arrangement, outdoor type of dimesions 200 X 140X 95mm (H X W X D) Product codeGS - JB- 3016S Make: Sintex or equivalent approved by GE.
Supply and lay cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armored, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor of size 25 Sqmm 4 core.complete all as specified and directed by Engg –in-charge.
Supply and lay cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armored, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor of size 16 Sqmm 2 core.complete all as specified and directed by Engg –in-charge.
Supply and lay cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armored, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor of size 10 Sqmm 2 core.complete all as specified and directed by Engg –in-charge.
Supply and lay High density polyethylene pipes (HDPE) of size 15 mm bore pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.complete all as specified and directed by Engg –in-charge.
M & L for sand filling in trenches for cable cushioning with clean dry fine sand, including gently punning around cable complete all a specified and directed. (NOTE : Only punned thickness of sand will be measured and paid.)
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat size 250mm X 150 mm X 40 mm in trenches as protection to UG cable all as specified and directed. Make : Mehtab Tiles Indore, Hind Upleta/Sukhi Enterprise
M&L for galvanised steel water tubing light grade 50mm dia with all fittings laid under the roads, drains culverts and fixed on poles etc complete all as specified and directed by Engr-in-charge
S & F GI hot dip perforated cable tray of size 300 mm wide x 75 mm height with GI coupler plate at every 2500 mm with SS hardware fitted 1 feet above above the ground level with the help of angel of size 40mmx40mmx5mm and bracket complete all as specified and directed .
S & F GI hot dip perforated cable tray of size 300 x 75 mm wide with GI coupler plate at every 2500 mm with SS hardware fitted at wall upto height of 10 mtr with anchor fastner of size 6 mm dia complete all as specified and directed. Note:-Quoted rates shall be deemed to include vertical cable tray fitted to wall.
S&F in repair Sheet moulding compound (SMC) junction box of size 200 mm x 140 mm x 95 mm, comprising three phase aluminium bus bar and one No MCB SP, 10 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified and directed. Make: Sintex or equivalent approved by GE.
M&L for Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate n.less than 1.5mtr below normal. GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4 mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe medium grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 3 of SSR of part-I including testing on completion all complete as specified and directed . Note:-Quoted rates shall be deemed to include for GI wire with protection pipe up to 7.5 M length.
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerent - R 410a (ii) EER - min 3.5 w/w (5 star rating) (iii) Tonnage - 1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Daikin/ Hitachi/ O General
Note:- Following will be inclusive in rate:- (a) Piping length upto 15 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) Contractor will provide warranty of 5 years for compressor from the date of installation (f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner (g) Contractor provide complete free service in warrenty period by the company
Supply and installed voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stablized at 230V with accuracy of (+,-) 2.5 % and capacity 4 KVA complete all as specified and directed.
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 4 Sqmm drawn through in and including Non metallic PVC casing caping into wall / ceiling with all accessories with 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed . Note: Three runs of 4.0 sqmm copper cable including PVC casing capping will be measured as one RM.
S & F in repair metal clad plug & socket board Single pole and neutral enclosure with two pin and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and as directed. Make- Anchor/Legrand/L&T
S&F Air termination, Star pointed copper rod 14 mm dia and 500 mm long with copper Air Rod fixed in position on pole complete with clamp and nut bolts all as specified and directed.
Supply & fix aluminium strip 25 mm x 3.15 mm complete with saddles and fixing screws for fitting the strip.
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size of 75 mm x 75 mm x 25 mm drilled and screwed fixing in FRP box complete all as specified and as directed.
Supply and fixing GI tubing of size 40 mm bore light grade ISI marked laid in trenches / on floor ceiling etc including with all fitting such as elbow, union reducer tees bends etc and short length for cable protection including taking down old GI tubing complete all as specified and directed.
Material and labour for renewal of earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI strip 32x6mm mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed. Note:-Quoted rates shall be deemed to include for GI strip with protection pipe up to 7.5 M length.
EVEREST BUILDERS
Honest builders
Vijay Construction Co
nasreenenterprise
Shree Khodal Infra Project
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .