| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,697Accepted-AOC MU COMPLEX GROUND FLOOR NEAR PVS HOSPITAL KOZHIKODE 673002 | KOZHIKODE | KOZHIKODE | KERALA | 673002 | ₹84,697 Quoted ₹84,697.41 | L1 | Accepted-AOC Lowest valid tender |
| 2 | L2₹89,440.47Rejected-AOC | ₹89,440.47 | L2 | Rejected-AOC Second lowest valid tender |
Tender Value
Refer Docs
EMD Value
₹2,117
Closing Date
18 Mar 2026, 6:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer, PWD Electrical Sub Division, Kozhikode
GENERAL-Urgent Maintenance Work 2025- 26 for Sub Collectors Office, Civil Station, Kozhikode.-Sub Collectors Office Maintenance Work-Electrical maintenance-General Electrical Work
2026_PWD_846332_1
PWD/BLDG/TR/3624/2026
Open Tender
Electrical Works
90 days
Kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
₹2,117
4 Jun 2026
11 Mar 2026
21 Mar 2026
11 Mar 2026
18 Mar 2026
11 Mar 2026
Providing Additional EI
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD343852/2025-2026:Supply, Conveyance, installation, testing and commissioning of 1000 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD346567/2025-2026:Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
OD341744/2025-2026:Supply and Installation of ISO certified pure sine wave Inverter suitable for 2-3 hrs back up with the following specifications, a. Capacity & DC Voltage : 3750/48V b. Input Voltage range : 160-285 Volt AC Single phase c. Output voltage : single phase 230V AC with voltage regulation 1% d. Waveform : True Sine wave e. Display: Digital Display for the status of Power back-up/battery charging time in hours and minutes f. Warranty : 3 year on-site warranty for Inverter. Make: hykon SPPLUS 3750/48V (2100W) or equivalent.
OD341743/2025-2026:Supply and installation of 150AH Tubular batteries 4 nos with inter connecting cables. Warranty 3 year replacement. Make Hykon or equvalent approved by engineer in charge. The total rate includes the buy back rate of existing 6 numbers of old 180AH tubular batteries.
OD346259/2025-2026:Cutting the tiled/concrete floor for laying PVC pipes including making good the surface etc. as required
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1429769.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tendernotice_2.pdf
PDF • 0.37 MB
Tendernotice_3.pdf
PDF • 0.19 MB
Tendernotice_4.pdf
PDF • 0.47 MB
nit.pdf
Tender Documents • 0.02 MB
sbd.pdf
Tender Documents • 1.81 MB
materiallist.pdf
Tender Documents • 0.18 MB
BOQ_1429769.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid