Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.7 L+₹27,168.83 (6.17%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹4.4 L
EMD Value
₹11,010
Closing Date
21 Mar 2025, 5:00 pmClosed
AE
LSGD Sub Division, Veliyanad Block
Annual Plan-VBP S0129/24-25-Additional parking facilities for two wheelers in Pulincunnu Taluk Hospital in Veliyanad B P- General Civil Work
2025_LSGD_750477_1
22/VBP/AE/LSGD/2024
Open Tender
Civil Works - Others
Item Rate
180 days
Mapuzhakkary
Please refer Tender documents.
10 documents required · 10 mandatory
₹975
Yes
₹11,010
Yes
9 Apr 2025
14 Mar 2025
25 Mar 2025
14 Mar 2025
21 Mar 2025
14 Mar 2025
Amount
Parking area
OD359184/2024-2025:Construction of subgrade and earthen shoulders, Construction of subgrade and earthen Shoulders with approved material obtained from borrow pits with all lifts and leads ,transporting to site , spreading , grading to required slope and compacted to meet requirement of Table 300.2 with lead up to 1000 mas per Technical Specification Clause303.1
OD359188/2024-2025:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing local meterialwell l, spreading in uniform layers with motor grader on prepared surface, compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 408. Using gravel mix soil.<br> (i) For Grading I Material
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
OD359272/2024-2025:Laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6mm sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
OD362618/2024-2025:Supplying and fixing PVC Square pathi gutter for UPVC rain water gutter section including fitting with 20 x 6 mm flat supporters at 1 m interval etc. complete
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
OD359619/2024-2025:Supplying and fixing granite name board of size 75 X 60 cm including engraving letters etc. complete as per the direction of departmental officers at site
Road Concreting
75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
LOVELY CONSTRUCTION (BID ID -2165938)
Bidder Name
JOJY JOEPH
LOVELY CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1215111.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .