Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | ₹35.9 L | L1 | Accepted-AOC ACCEPTED - AOC |
| 2 | L2₹36.8 L+₹86,308 (2.40%)Rejected-AOC | ₹36.8 L+₹86,308 (2.40%) | L2 | Rejected-AOC REJECTED - AOC |
| 3 | L3₹37.5 L+₹1.5 L (4.28%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹37.5 L+₹1.5 L (4.28%) | L3 | Rejected-AOC REJECTED - AOC |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
30 Oct 2019, 6:00 pmClosed
GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT
Special Repair of pipe Lines of FAFA Accn/ Md Accn At Mall Road / Young Road, Spl Repair of LT Distribution Cable, Meter Box etc in Robert Line, Sulva Line in Ghanghora and Spl Repair of SCADA system at Bijapur Filtration Plant and other Insulators
2019_MES_286390_1
8141/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEHRADUN
Class D Cat a(i)
7 documents required · 7 mandatory
₹500
GE DEHRADUN
₹89,000
Yes
29 Jan 2020
1 Oct 2019
1 Nov 2019
1 Oct 2019
30 Oct 2019
15 Oct 2019
Amount
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminiium conductor, 1100 volts cross sectional area 16 Sq. mm 4 Core laid in trenches/along poles/along walls all as directed incl lugs thimbles and gun metal cable glands and heat shrinkable PVC sleeves on exposed surfaces and tuflon tape duly insulated complete including taking out existing unserviceable cable. Make: KEI/Havells/Grandlay Note: Earth work, sand,protection cover, protection pipe shall be measured and paid separately under respective items.
M&L for excavation in trenches not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in hard/dense soil including cutting in slopes etc for laying of pipe line/ cable etc including getting out, complete all as specified and directed.
Supplying and layfilling dry river sand for cable protection with a layer of 8cm thick before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
Supply and laying Reinforced precast concrete cable cover class LV Type-I flat size 250mmx150mmx40mm complete all as specified and directed.
M&L for excavation in trenches not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in soft/loose soil including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed.
M&L for excavation in trenches in hard rock/road cutting not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed.
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers in any type of soil not exceeding 25 cm in each layer complete all as specified and directed by Engineer-in-Charge.
M&L for removal of excavated material (Soil) to a distance up to 50 Meter from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed by Engineer-in-Charge.
Supply, Installation in replacement, testing and commissioning of metering distribution board indoor/ wall mounting thermoplastic polycarbonate IP-65 in accordence with IEC-60-529 suitable for 415 Volt 3 phase 4 wire 50 Hz AC for housing 4 Nos electric meter of dimension 600x900x180mm and supply system having busbar chamber with copper bus bars duly insuslated by RYB colour 100 amps rating mounted on porcelain insulators and made out of modular polycarbonate thermoplastic enclosuresand enlcosure shall be environmentl freidnly recyclable UV resistant halogen and silicon free anti acid and antio corosive comprising of MCCB 415V 63 Amps 4Pole 16 KA as Incomming type tested as per IEC-61-439-1, load should IK08 (5 Jule) an accordence with IEC-62262 with CPRI approved and 16 Amp DP 10 A MCB 04 Nos of each outgoing and 25sqmm triminal block 08 Nos and incl complete elecric connectin with main incoming LT cable Make: HENSEL/ SIEMEMS/L&T. Note ;(a) Cost of MCCB/ MCBs are included in the item rate. (b) Old electric meters shall be taken down and deposited in E/M store. (c) New Electric meters shall be measured and paid seperaterly.
S&F in repair sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
S&F in repair of tamper proof electronic single phase whole currrent energy meter (self powered LCD display) 10 Amp to 60 Amp, 240 volt class 1.0 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with at least 2 anti tamper LED indications of line load reversal and earth loading indication including electrical connection with existing system and sealing properly in meter box on and incl 3 mm thick bakelite sheet. The meter shall work satisfactory with guaranted accuracy as per limit of IS: 13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Make:- Secure/L&T/BHEL (Note:- Old unserviceable meter will be deposited to E/M store yard)
S&F in repair 25 mm bore steel for tubing light grade ISI marked laid in trenches etc for protection of cable including necessary joint complete all as specified and as directed.
Dismantling and taking out the existing corroded/ scaled GI pipe with fittings connection from trenches, walls, ceiling or floor and removal from site or disposed off for the following sizes complete all as specified and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule 'A'.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, Laying, fixing & testing galvanised iron water tubing 'medium grade; ISI marked with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule "A" only in case of pipe line is re-routed other wise excavation and earth work already executed for taking out pipes shall be considered. Make: Tata/ Prakash
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Laying, fixing & testing galvanised iron water tubing 'medium grade with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc fixed to walls laid in floors for the following sizes complete all as specifed and directed. Note: (a) Excavation and earth work shall be measuered and paid seperately under respective item of schedule "A" only in case of pipe line is re-routed other wise excavation and earth work already executed for taking out pipes shall be considered (b) Old tubing retrieved from dismantling shall be reused after cleaning, cutting, threading as required.
20 mm bore
25 mm bore
Dismantling and taking out the existing CI distribution mains/ sub mains/ rising mans with fittings spigot and scoket ends and lead joints from trenches including burning out joints recovering lead and removal from site for the following sizes complete all as specified and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule 'A'.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Supply& fixing CI Pipe line with and inclduing all CI fittings such as flanges, reducers sockets, socket reducing bends , elbows, tee, etc in laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A" Make: Electrosteel/ KDPUL/Upadhyay
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
M&L for boring/drilling by mechanically/mannual horizontally under the road in any type of soil with out cutting/distubing the existing road and inserting the GI pipes of any size complete all as specified and directed Note: GI pipe shall be measured and paid seperately under respective item of schedule'A'
Dismantling/taking out defective Gun metal gate valve and S&F for Gun metal gate valve with iron wheel head by screwing/cutting of existing pipe lines for the following size complete all as specifed and directed. Make: Leader/ Zoloto/ Vardhman
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F in repairs 20 mm dia ball brass valve high pressure with polythene float and fly nut complete all as specifed and directed.
S&F in repair CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle and nuts stuffing box etc type PN - 1.6, ISI marked of following sizes:- Make: Sant/ BIR/Zoloto
80 mm bore
100 mm bore
150 mm bore
Material & labour for inserting the connection in the existing distribution pipe line with the help of welding, clamp joint or as per site requirment for 50 to 150 mm dia bore complete.
Dismantling existing unserviceable Alum dozing station level transmitter and S&F Alum dozing station level transmitter with probe type level transmitter 3 mtrs, 4-20mADC, SMPS, LCD display TYPE CLtx complete. Make: complete Make : Nivo/ Toshbro/ Cirrus
Dismantling existing unserviceable caustic dosing station level transmitter and S&F caustic dosing station level transmitter with probe type level transmitter 2 - 3 mtr long, 4-20mADC, SMPS, LCD display type MFTx complete Make : Nivo/ Toshbro/ Cirrus
Dismantlilng existing unserviceable Electromagnetic flow meter for feed line and S&F Electromagnetic flow meter for feed line with magnetic flow transmitter 300 NB with flange, IP67, 4-20mADC, type MFTx complete Make : Nivo/ Toshbro/ Cirrus
Dismantlilng existing unserviceable Level transmitter for overhead backwash reservoir and S&F Level transmitter for overhead backwash reservoir with probe type level transmitter 2-3 mtr, 4-20mADC, SMPS, LCD display complete Make : Nivo/ Toshbro/ Cirrus
Dismantlilng existing unserviceable Level transmitter for Filters and S&F Level transmitter for Filters with probe type level transmitter 2-3 mtr, 4-20mADC, SMPS, LCD display complete Make : Nivo/ Toshbro/ Cirrus
Dismantlilng existing unserviceable Level transmitter for Filter water tank and S&F Level transmitter for Filter water tank with probe type level transmitter 2-3 mtr, 4-20mADC, SMPS, LCD display complete Make : Nivo/ Toshbro/ Cirrus
Dismantlilng existing unserviceable Level transmitter for Raw water sump and S&F Level transmitter for Raw water sump with level transmitter probe, online configration through IR remote, Max 6M distance, 24 VDC, 4-20 m ADC complete Make :Emerson/ Nivo/ Siemens
Dismantlilng existing unserviceable waste water pond level transmitter and S&F waste water pond level transmitter with level transmitter probe, online configration through IR remote, Max 6M distance, 24 VDC, 4-20 m ADC complete. Make :Emerson/ Nivo/ Siemens
Dismantlilng existing unserviceable online pH meter and S&F online pH meter 0-14, suitable to operate 4.2mA DC complete. Make :Emerson/ ABB/ E&H
Dismantlilng existing unserviceable online ORP meter and S&F online ORP transmitter complete Make :Emerson/ ABB/ E&H
Dismantlilng existing unserviceable KWh meter and S&F KWh meter with Energy pulse transmitter and compatible to exiting Skada system installed at New Bijapur water treatment plant. complete Make : ABB / L&T/Schneider
Dismantlilng existing unserviceable on-off valve and S&F on-off valve with 3 inch valve with actuator and SOV for final pumping station complete Make : Rotex/Tecnik/ Samson
Dismantlilng existing unserviceable on-off valve and S&F on-off valve with 6 inch valve with actuator and SOV for raw water section complete Make : Rotex/Tecnik/ Samson
Dismantlilng existing unserviceable flow switch for pump and S&F flow switch for pump complete. Make : Indfos/ Danfoss/ Cirrus
Dismantlilng existing unserviceable pressure switch for pump and S&F pressure switch for pump complete. Make : Indfos/ Danfoss/ Cirrus
Dismantling existing unserviceable parts of outlet filter No 1 Line size 250 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) repairing and refixing actuator unit
(b) S& F new solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of rince filter No 1 Line size 250 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of filter No 1 Inlet Line size 250 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of filter No 1 Backwash outlet Line size 350 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of filter No 1 Backwash Inlet Line size 350 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of Air blower Line size 100 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of Raw water unit Line size 150 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
(d) Repairing and refixing Hand wheel unit
Dismantling existing unserviceable parts of Pump section Line size 50 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
Dismantling existing unserviceable parts of Chlorination unit Line size 50 mm dia and refixing same/ new part in repair including necessary nut/ bolts screw and connecting up complete as follows:
(a) Repairing and refixing Actuator unit
(b) S& F new Solenoid switch
(c) S&F new Feedback unit consiting of limit switch unit and mounting
Note: Item Nos 23 to 46 shall be fixed in the exiting Skada system installed at New Bijapur water treatment plant and same should be compatible to fit in the existing system. Any modification required to fit in the existing system shall be made by the contractor as per without any extra cost to the Govt. The contractor shall visit the site to ascertain all details and accordingly quote the rates.
M/S Electrotech Sales
Friends fire Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .