Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC Accepted as L1 Lowest Bidder |
| Sl No | Description | Qty | Unit | M/s Raj Construction L1 |
|---|---|---|---|---|
| 1.00Note: The Bidder must quote the values inlcuding Taxes. | ||||
| 2.00CIVIL WORK | ||||
| 3.00Earthwork | ||||
| 4.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soils | 1,086 | cum | 237 ₹2.6 L |
| 5.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited) | 179 | cum | 1,917 ₹3.4 L |
| 6.00 | Extra for every additiobnal lift of 1.5m or part thereof in excavation/banking excavated or stacked materials.
All Kinds of Soils | 563 | cum | 169 ₹95,147 |
| 7.00 | Extra for every additiobnal lift of 1.5m or part thereof in excavation/banking excavated or stacked materials.
Ordinary or Hard Rock | 63 | cum | 304 ₹19,152 |
| 8.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 897 | cum | 262 ₹2.4 L |
| 9.00 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. | 160 | sqm | 1,182 ₹1.9 L |
| 10.00CONCRETE WORK | ||||
Tender Value
₹3.5 Cr
EMD Value
₹7 L
Closing Date
19 Dec 2025, 3:00 pmClosed
Superintending Engineer, 7th Circle PWD Gopeshwar
Office of SE, 7th Circle PWD Gopeshwar
Construction of Bala Sundari Temple under Mana Sustainable Tourism Development Plan in District Chamoli
2025_pwd_89492_1
4557/544 yata-07/2025 Dated 01.12.2025
Open Tender
Civil Works - Buildings
540 days
Mana
Please Refer Tender Documents.
2 documents required · 2 mandatory
₹5,900
EE PIU PWD Badrinath
₹7 L
Office of SE, 7th Circle PWD Gopeshwar
11 Apr 2026
4 Dec 2025
19 Dec 2025
4 Dec 2025
19 Dec 2025
5 Dec 2025
11 Dec 2025
Amount
Note: The Bidder must quote the values inlcuding Taxes.
CIVIL WORK
Earthwork
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soils
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited)
Extra for every additiobnal lift of 1.5m or part thereof in excavation/banking excavated or stacked materials. All Kinds of Soils
Extra for every additiobnal lift of 1.5m or part thereof in excavation/banking excavated or stacked materials. Ordinary or Hard Rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works upto plinth level
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
CENTERING AND SHUTTERING
Centering and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts
MASONRY & PLASTER WORK
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 In cement mortar (1:5)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
CLADDING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 SqM
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete
Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately).
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion, Fastener with threaded dia 10 mm
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Himalayn Stone Cladding 50mm thick (450x200x50)mm
DOOR & WINDOW WORK
Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. Sal wood
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood, 35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick, second class teak wood.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH GS Size 200 mm
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH AB Size 100 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. Model no- VX Size (200x12) mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. Model no- VX Size (150x12)mm,
Providing and fixing bright finished brass 250 mmmortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Model No-Lever Handle Tango CY with Lock body and cylinder 60mm OSK
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete: Size (100x75x3) mm
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete: Size (125x75x4) mm
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Size 150 mm
WOOD WORKS
Providing and fixing Second Class Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank.
Providing and fixing 2nd class deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25 mm thick
Providing, laying and fixing of Second class deodar wood as in built runner having size of 100mmX70 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface without additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc.. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer/ sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification.
25 mm wooden planking, tongued & Grooved in Ceiling , including fixing with iron screws complete with 150 mm wide second Class deodar wood plank.
Providing and fixing 2nd class deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25 mm thick
M.S. & STEEL WORK
Steel work in built up tubular (round, s quare or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing M.S. grills / Railings of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws, etc.
FLOORING
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mi xed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing & Laying 100 mm thick cobble stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Rajasthan Black Granite Cobble Stone Machine Cut, Four sides machine cut and two sides Rough Surface. (100x100x100) mm (+-5% of size)
70 mm thick fine dressed Local Himaliyan stone flooring for external works over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.
FINISHING & PAINTING WORK
12 mm Cement Plaster of mix : 1: 6 (1 cement: 6 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
French spirit polishing : Two or more coats on new works including a coat of wood filler
Hydro Oil For Exterior Coating Two or more coats on new works including a coat of wood filler
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : (PU COATING) Two coats using aquulac Repellin WR-003/Durabuild D088
Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Eq. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a complete job. Note: (i) Overlapping has to be provided between two laminated Asphalt Shingles sheets as per the norms. The overlap quantity will not be considered for the measurement/ payment
SUB-BASES, BASES (NON- BITUMINOUS) AND SHOULDERS
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Granular Sub-base with Close Graded Material (Table:- 400-10) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For grading- I Material
EARTH WORK, EROSION CONTROL AND DRAINAGE
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 110 mm dia U-PVC pipes extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
RCC MANHOLE
Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality. pre-cast R.C.C. manhole cover and frame of required shape and approved quality. ELECTRICAL MANHOLES
EM-C-450x450x500mm ELECTRICAL & ELV MANHOLE
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kgs/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Form Work : Centering and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centering and Shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Elecrical Part
LT PANELS
Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle Panel board. Detail specification shall be followed. Shifting of panels from site store to the suitable location. Assembling and wiring of component supplied separately. Earthing all components, frame etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories, supporting structure, hardware etc. to complete the job. Supply, installation, testing and commissioning of necessary tools, hardware, testing hardware, testing equipment etc. The rates for the distribution boards apart from the Breakers and instruments shall also include the following : This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosed. Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. If any TPN ACB’s / MCCB, it shall be with adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity. The breaking capacity of MCCB’s are mentioned panel wise.
All MCCB’s shall be with thermal magnetic releases upto 250 amps and microprocessor based above 250 amps capacity, unless specified otherwise. All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 4X for all Indoor panel. IP 54 and double door. All MCCB’s shall be provided with operating mechanism for door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. SPD as shown in SLD Approved Makes-L&T/ABB/schnider/Legrand/SIEMENS
Supply, Installation, testing and commissioning of IP 43 rated FACADE/EXTERNAL LIGHTING DB Having, Incomer: 25A,DP RCBO (30mA-10KA) (01 No). AUTO MANUAL SWITCH WITH SINGLE CHANNEL DIGITAL TIMER WITH 48HR BATTERY BACK-UP AUTO-MANUAL BY-PASS SWITCH 25A, DP CONTACTOR (1NO.) Out Going: 6 Amp SP 10KA MCB (08Nos) ALSO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. NOTES FOR SLD: 1. CONTRACTOR TO CONSIDER SINGLE CHANNEL ASTRONOMICAL TIMER SWITCH. 2. OUTGOING CIRCUITS SHALL BE DIVIDED IN ONE CHANNEL. 3. ALL REQUIRED CONTROL WIRING OF TERMINAL BLOCK SHALL BE PART OF SCOPE.
DISTRIBUTION BOARDS
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing of weatherproof enclosure for double pole, 240 volts, MCB (6A-32A) complete with connections, testing and commissioning etc. as required. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door (IP43, IK09)
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 32A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A
Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
MV CABLES
Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.
Upto 35 sq. mm
Laying and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS
3.5C x 25 Sq.mm. Aluminum XLPE armored cable
4C x 16 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
4C x 4 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
CABLE TERMINATION
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI
3.5C x 25 Sq.mm. Aluminum XLPE armored cable
4C x 16 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
4C x 4 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
INTERNAL WORKS
Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring.
Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E) Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E) Cost of MCB shall not be considered in point rate. Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles, etc. For Exhaust fan
Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required- Group C
Light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
CONDUIT & OTHER
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
EARTHING
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. Approved Makes-OBO/ JEFF/ JMV
LIGHT FIXTURES
20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures: 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make BN021C LED20S PSU CW GR S2 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies
Weather Proof Downlighter : Supply of CEILING LED Fixture -LED 12W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current, IP 66 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Philips/Lighting Technologies
Supply of Weather Proof Downlighter (On Roof Chajja) Recessed Celiing Light - 10W,800lm,IP65,3000K, Dimension 100X80mm, Height 80mm Diameter is 100mm, Weight is 0.5kg, Fixing Suitable for ceiling-mounted recessed installation. Fixture is made of Die Cast Aluminium, Powder Coated, LED is COB, Inbuilt driver, Input AC 240V, 50/60Hz * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Philips/Lighting Technologies/NCRL-10S Neri Model NCRL-10S
Landscape Bollard Supply, laying, connection and testing of Landscape Bollards 15Watts Bollard LED, IP66, 800/100mm. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - NERI/Philips/Lighting Technologies
JUNCTION BOXES
Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE
DWC PIPES
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Providing & Laying of HDPE Pipe 32mm PE-80,PN6 direct in ground; to be laid 75-100cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering,or G.I. conduit 32 mm dia( Heavy Duty) with concrete block 15cm X 15cm 1:2:4 with complete curing with splicing complete in all respect complete in all respect. Make: Jain/Dutron/Supreme/reliance
CABLE TRAY
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
stage.html
html • 0.04 MB
technical_106107.pdf
techsummary_106107.pdf
finance_106107.pdf
BOQ Comparative Chart
xlsx
finsummary_106107.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.78 MB
SBDBalasundariTemple2ndtime.pdf
Tender Documents • 10.84 MB
BOQ_106107.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid