Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹37.7 L+₹2.8 L (7.94%)Rejected-Finance | L2 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 3 | L3₹38.3 L+₹3.3 L (9.57%)Rejected-Finance | L3 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 4 | L4₹38.8 L+₹3.9 L (11.1%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 5 | L5₹41.2 L+₹6.3 L (17.9%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Rejected for acceptance being not lowest. |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
10 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
OUTSOURCING OF RESOURCES FOR MANAGEMENT AND OPERATION OF E/M INSTALLATIONS AT AIR FORCE STATION DWARKA AND KHAMBHALIYA UNDER GE (AF) JAMNAGAR NO.2
2020_MES_382074_3
8262/E8
Open Tender
Miscellaneous Works
Works
330 days
Jamnagar
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jamnagar No.2
₹70,000
Yes
4 Mar 2021
27 Jan 2021
17 Feb 2021
27 Jan 2021
10 Feb 2021
3 Feb 2021
60 days
Amount
General Notes: - (i) Contractor’s special attention is invited that Estimated cost for Outsourcing of resources for management of & operation of E/M installation at AF station Dwarka and Khambhaliya Rs.29,95,980.00 based on prevailing rate of Schedule of Minimum fair wages. If the quoted amount is less than the amount the work, then the lowest bidder will have to deposit FDR/BGB in favour of Accepting Officer within 07 days of opening of Financial Bid for the difference in estimated cost & quoted amount. (ii) In case the said FDR/BGB is not submitted within stipulated period as mentioned above, the contractor shall be banned for 06 months & their bid will be rejected and finance bid will not be opened. FDR/BGB submitted shall be released only after satisfactory completion of work on submission of proof of payment that all the person deployed under this contract has been paid not less than Schedule of Minimum fair wages as mentioned under Note No.4.3 to 4.5 here in after.
Outsourcing for Management and Operation of Water Supply Installation and Operation of compact filtration plant, located at Air Force station khambhaliya domestic area for continous operation (as per schedule) of various assests such as operation of valves for filling of OHT(50000 Glns) and UG sump(50000 Glns),operation of valves for distribution of drinking water as per schedule and operation of various assests such as Pumps, motors, chemical dozing plant,filtration plant and back washing system on daily basis and water supply headers to provide water supply to various users inside technical/domestic area by providing one fitter general mechanic (FGM), with minimum 2 years of experience for opeartion of pumping and distribution system, for shift of 8 hours with 3 shifts per day (including sunday and National holiday).
The water supply installation comprising of following components (a) Submersible multi stage pump set directly coupled with 17.5HP 3 phase electric motors- 04 Nos(b) Centrifugal Pump set coupled with 20HP 3 phase electric motor-02 nos.and Centrifugal Pump set coupled with 30HP 3 phase electric motor-02 nos (c) NRV 100mm = 04Nos. (d) Sluice Valve/ Butterfly valve / Gate valve of size 50/80/100mm = 21 Nos. (e) Motor control starter panels = 03 Nos. (f ) Diesel generating set 20KVA -01 nos and 50KVA-01 nos.(g) LAMPACK Filtration plant (h) Water supply headers -02 nos The Contractor shall be responsible for routine/preventive maintenance of eqipments(DG set and Pumping set) and accessories , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair to leakage from pumps by providing gland packing, replacement of flange gasket in valves and maintenace of control panel for pumping set/LT panel , tightening of loose connections in panels and providing insulation on burnt /exposed cable/wire etc.
The contractor should carry out routine/periodic maintenance of all installed equipment/components as per schedule mentioned at particular specification. The contractor and his opeartor must adhered to all instructions contained in Notes and Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions contained in Notes and Particular specification may leads to recovery as deemed fit at the discretion of Accepting officer.
Outsourcing for Management and Operation of water supply installation and operation of RO Plant cap 1000 to 10000 ltrs/day located at Air Force station Dwarka domestic area for continous operation (as per schedule) of various assests such as , operation of valves for filling of UG sump(50000 Ltr -02 nos),operation of valves for distribution of drinking water as per schedule , operation Pumps and motors, chemical dozing plant , water supply headers to provide water supply to various users inside domestic and technical area by providing one fitter general mechanic (FGM), with minimum 2 years of experience for opeartion of pumping and distribution system, for shift of 8 hours with 3 shifts per day (including sunday and National holiday)
The water supply installation comprising of following components (a) Submersible multi stage pump set directly coupled with 7.5HP 3 phase electric motors- 1 Nos(b) Monobloc Pump set coupled with 7.5HP 3 phase electric motor-02 nos.(c) Solar module DC operated solar water pump cap 5.0HP -01 nos (d) NRV 80mm - 03Nos. (d) Sluice Valve/ Butterfly valve / Gate valve of size 50/80mm -07 Nos. (e) Motor control starter panels - 02 Nos. (f ) Diesel generating set 20KVA -01 nos. (g) servo controlled Voltage stabilizer 150 KVA -01 (h) Active Harmonic filter panel 60A 3 phase 01 nos. The RO Plant comprising of following components (a) Indion new generation multigrade filter -01nos (b) Chemical dosing system-02nos(c) Activated carbon filter-01nos (d) Reverse Osmosis system -01no with UV sterlizer , ozonator , sensors pump and interconnected piping complete
The Contractor shall be responsible for routine/preventive maintenance of eqipments(DG set and Pumping set) and accessories , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair to leakage from pumps by providing gland packing, replacement of flange gasket in valves and maintenace of control panel for pumping set/LT panel , tightening of loose connections in panels and providing insulation on burnt /exposed cable/wire etc.The contractor should carry out routine/periodic maintenance of all installed equipment/components as per schedule mentioned at particular specification. The contractor and his opeartor must adhered to all instructions contained in Notes and Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions contained in Notes and Particular specification may leads to recovery as deemed fit at the discretion of Accepting officer.
Outsourcing for Management and Operation of Electric supply installation(Main Receiving station) at Air Force station Khambhaliya including operation of HT/LT panels ,Operation of Compact sub station and APFC panel, servo voltage stabilizer and electrical control panel for street light in technical and domestic area for continous opeartion for 16 hrs by providing electrician highly skilled (proficiency in operation of HT 11KV electrical control system), with minimum 2 years of experience for in handling of HT 11 KV electrical installation, for shift of of 8 hours with 2 shifts per day (including sunday and National holiday)
The contractor shall be responsible for testing of earthing to HT/LT equipments on monthly basis and periodical testing of lightening conductors inside technical and domestic area.The electric suplly installation comprising of following components:- (a) Indoor Ring main unit HT 11KV, 630 amps, 3way(b)Compact sub stn consisting of indoor 11KV HT VCB , 160KVA Transformer, LT Panel and APFC Panel -01 nos (c )Compact sub stn consisting of indoor 11KV HT VCB , 315KVA Transformer, LT Panel and APFC Panel -01 nos (d)LT distribution panel-03 nos (e)Voltage Stabilizer 200KVA -01 nos .
The Contractor will also be responsible for routine/preventive maintenance of eqipments and accessories , cleaning of surrounding area of the installation and the building , earth pits , and area around the CSS. Maintenace of control panel /LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification. The contractor and his opeartor must adhered to all instructions contained in Particular specification. The contractor and his opeartor must adhered to all instructions contained in Notes and Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions contained in Notes and Particular specification may leads to recovery as deemed fit at the discretion of Accepting officer.
Outsourcing for Management and Operation of Electric supply installation(Main Receiving station) at Air Force station Dwarka Technical area including operation of HT/LT panels and other connected electric supply distribution system like operation of GOD switch, changes of HT fuse, HT/LT underground cables , servo voltage stabilizer and electrical control panel for street light in technical and domestic area for continous opeartion for 16 hrs by providing electrician highly skilled (proficiency in operation of HT 11KV electrical control system), with minimum 2 years of hands on experience for in handling of HT 11 KV electrical installation, for shift of of 8 hours with 2 shifts per day (including sunday and National holiday).
The contractor shall be responsible for testing of earthing to HT/LT equipments on monthly basis and periodical testing of lightening conductors inside technical and domestic area.The electric suplly installation comprising of following components:- (a) Vaccum circuit breaker unit HT 11KV, 630 amps, 3way-01 nos (b)Transformer outdoor type 250KVA -01nos (c) Servo controlled Voltage Stabilizer 250KVA -01 nos (d)LT distribution panel-04 nos (e)Active Harmonic filter panel 60A 3 phase-01 nos(f) APFC panel -01 nos .
The Contractor will also be responsible for routine/preventive maintenance of eqipments and accessories , cleaning of surrounding area of the installation and the building , earth pits , and area around the transformer. Maintenace of control panel /LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification.The contractor and his opeartor must adhered to all instructions contained inNotes &Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions may leads to recovery as deemed fit at the discretion of Accepting officer.
Notes for Item no.1 to 4: 1. Wage paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State/Central Government from time to time whichever is higher. The payment shall be made to the workers through a nationalised bank and the bank statement of fair wages as per minimum labour wages as mentioned above shall be submitted along with the RARs/FB for payments 2. The contractor shall be responsible for the EPF, ESI, bonus, Safety etc. and insurance of all trademen employed by him as per existing Labour Rules/Acts/Regulations 3. Contractor special attention is invited that payment of operator / labour shall be made only through online mode only and same shall be deposited in Adhar link account of operator / labour. Documentary evidence for the same shall be submitted to Engineer -in-Charge before payment of RAR / Final bill. 4. Contractor and his personnel detailed for manning of Pump house shall be responsible for serviceability of Pumpset,Diesel engine generating set, Valves. In case of any major fault occurs in above mentioned items, he will be report directly to concerned JE E/M / AGE E/M. Person deputed for operation will be responsible for minor maintenance such as checking of oil, checking of Diesel, oiling and greasing of Valves,Drawing disinfectant from MES and pouring it to dozing system to maintained required PPM level as per IS norms, informing MES and maintaing sufficient balance in storage tank for DG set as and when required, checking of battery terminal and cleaning of DG Sets,Pumpset,Valves cleaning of Pump house room and surrounding areas complete. 5. Contractor and his personnel detailed for manning of electric supply installations shall be responsible for operating of HT/LT breakers,Preventive maintenance of power house equipment.Maintaining of proper HT/LT voltage and replacement of HT fuses within resonable time.Ensure proper shut down of HT/LT breakers as per rules and policy in vogue.Maintenance of log sheet and recording of breakdown/fault timming during shut down/failure of electric supply.Maintaining proper voltage of DC battery bank and ensure proper functioning of batteries by timely repair/preventive maintenace.For any kind of maintenance/repair of HT Panel/GOD switch/on HT pole at power house and installation trademan on duty should ensure proper shut down of electric supply before commencement of repair work. 6. Necessary weekly off will be given to all the manpower employed for this schedule as per existing rules and regulation of state /central govt. and necessary replacement or reliver shall be provided by the contractor. Rates quoted for this schedule shall deemed to be include the payment of reliever also.nothing extra shall be admissible on this account.
Notes Contd ......../ 7. In case absence of any operator / workmen from any shift will be penalized with a penalty of double the rate quoted by the contractor in addition to the shift not taken in to consideration for payment. Attendant / Operator wanting leave will get it sanctioned before proceeding on leave along with the name of individual who will be performing his duty/shift in his absence. No replacement of operator/workmen without the knowledge of department will be allowed. 8. Safety equipment's, tools and first aid kit ,sanitization kit and hand gloves must be provided by the contractor to all tradesman without adding any extra cost to government.Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 08 days from the date of commencement. 9.Log book (Sheet), Muster roll, duty roster, fuel consumption register, daily breakdown register, attendance register and other requisite registers shall be maintained by operator and get it signed by concerned JE, Engineer-in-charge and contractor on daily basis and same shall be submitted monthly to accepting officer for inspection and other details as specified in PS. 10.Operator should posses ITI certificate in respective trade with minimum 02 years experience for running of installation and well conversant with the operation of HT/LT Installations, Pump set equipment's with connected panel and opeartion of DG set . The contractor must produce qualification and experience certificates duly attested by gazetted officer. For electric supply installation the operator should be ITI pass with 05 yrs of experience in handling of HT installation and must be holding proficiency certificate /license for HT 11 KV.The attested certificate shall be submitted to accepting officer at the time of commencement of work. 11. Contractor should be responsible for maintaining parameter such as TDS & PH as per IS standard. Any deviation of results in comparision to IS standard may attract penalty @ 500/- per day per report. Contractor must keep daily record of various parameter ( TDS & PH) and put up to AGE E/M weekly for correctness . Any measuring instrument/kit required for measurement of parameters must be provided by the contractor to the operator. 12. Contractor / his operator will be responsible for continous running of the installations any failure due to negligence of operator may attract penalty @ Rs. 500/- per hour till restoration. 13. The routine/preventive measures as per Appx "A" of above equipment /plant deemed to be included in the unit rates quoted against this item.
Notes Contd ......../ 14. Contractor should provide proper dressing to all the operator as directed by Engr-in- charge.Non compliance of instructions with respect to dressing may attract penalty @ Rs.200/- per day per operator. Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 15 days from the date of commencement. 15.Operator must inform JE/AGE concerned within half an hour in the event of breakdown or failure of Pumpset/motor and electrical panel and even leakage of pipeline.Delay on this part will be treated as negligence of operator , which can attract penalty and per note 13. 16. All necessary stationery required shall be provided by contractor as per sample , cost of this is included in the cost of item. Contractor must be responsible to maintain stock of chemicals for water treatment at all the times and must intimate to concerned JE/AGE three days in advance whenever active stock is about to finish. 17.Contractor or his operator ensure handing/taking over of assest during change of shift , any part/component at installation found missing/damaged due to negligence will be treated as wilful damage and for this cost of replacement shall be recovered from contractor payment due.as per direction of Engr-in-charge. 18.Contractor is fully responsible for any kind of mishaps/accident occurred due to ignorance/mishandling /misfunction/negligence while on duty by contractor operator.at the installations. Necessary insurance,for all operator, as per ESI rules must be obtain by the contractor.Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 15 days from the date of commencement. 19. Contractor is responsible for maintaining daily records for water distributed to users.Record should be put up to AGE E/M duly signed by contractor and JE E/M.Non -maintenance of records will attract penalty at @ Rs. 300/- per day 20. The contractor and his workmen shall comply existing labour laws, IE Rules, Factory act in totally
Deployment of man power for Collecting the sample of water, on monthly basis, from different point such as under ground sump , open well, bore well swimming pool and sewage treatment plant for chemical testing of water from reputed Govt Laboratory for iron content in water , PH value, Hardness, turbidity, chloride, fluoride and other parameters as per IS standard.Submitting the test report to Engr-in-Charge on 5th day of every month complete all as specified and as directed
Deployment of man power for Collecting the sample of water , on monthly basis, from different point such as under ground sump , open well, bore well swimming pool and sewage treatment plant for bacteriological testing of water including arsenic test from reputed Govt laboratory Submitting the test report to Engr-in-Charge on 11th day of every month complete all as specified and as directed.
Supply only calcium hypo chlorite high strength chlorination chemical (65% - 70%) for water disinfectant in granular from in factory sealed HDPE Container 45 to 50 Kg. Note: (i)Contractor must submit/produce test report with hologram for the each lot/batch (ii) Each drum must be affix with Hologram (iii) Contractor must submit in writing about the ordered qty, date of packing of each drum , batch no and nos of drums and date of dispatch either on his letter head or from authorised dealer letter head. (iv) Non submission and non availability of above information leads to rejection of drum/ entire lot for which contractor is wholly responsible. Make :- M/S Sree Rayalaseema Hi-strength Hypo Ltd. or any other make as approved by Zone/command/E-in-C branch from time to time
Supply only Potash Alum crystal type or Water Soluble Alum Crystals as a flocculant for water purification cpmplete all as specified and directed by Engr-in-Charge.
Supply only Poly aluminium chloride as coagulant/flocculent for transforming raw water in to clean and safe water for treated waste water ,inorganic soluble polymer powder in factory sealed 25 Kg HDPE bags wit two LDPE liners complete all as specified and directed by Engr-in-Charge. Make:Grasim Industries limlited " Vikram pac " AC/100S grade or equivalent make with ISI and NSF certification both Note: (i)Contractor must submit/produce test report with hologram for the lot/batch supplied by Grasim Industries Ltd to Engr-in-charge (iii) Each drum must be affix with Hologram
Supply only sodium hypo chlorite solution Grade -I low strength chlorination chemical (10% - 12%) for treated water disinfectant in factory sealed air tight HDPE Container 25 Lit /45 Lit conforming to IS 11673:11992 . Make:- M/S Sree Rayalaseema Hi-strength Hypo Ltd. or equivalent make with ISI and NSF certification both . Note: Each package should contain following information (a)Name and grade of material (b)Gross and net mass (c )Date of packing (d) Lot number (e) Indication of source of manufacturer.
M & L for servicing and maintenance of RO treatment plant cap 1000 to 10000 Ltrs /day by cleaning of filter catridge, cleaning and servicing of dosing pumps, motor,control valve, FRP insdustrial RO vessel, multi port valve, pre filter and membran system including minor repair to defective/ damaged pipe line for suction and delivery lines complete all as specified and as directed by Engr-in-charge. Note: (i) Routine/maintenance of various parts mentioned under this item shall be carried out twice in the year. (ii) All defective parts shall be replaced under respective items which shall be measured and paid seperately.
Supply and fix in repair Raw Water centrifugal mobobloc pump of capacity 2000LPH at 25MWC ,CI Material with 1.0HP power suitable for single phase 240 volts system, as per existing frame , complete all as specified and as directed by Engr-in-charge. Make: Grundfos/Crompton/Siemens/KBL
Supply and fix in repair Anitscalant Dosing pump electromagnetic type 0 to 1.5LPH capacity with pressure diascharge 2.0kg/cm2as per existing suitable for single phase 240 volts system, as per existing model , complete all as specified and as directed by Engr-in-charge. Make: Indion/Crompton/Siemens
Supply and fix in repair RO control valve 15mm dia made of stainless steel suitable for control line complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair blending line complete with blending valve and ICPW made of PVC higher grade suitable for RO water treatment plant as per existing capacity and grade complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair Jumbo Wound Cartridge Filter For Water Filter 20inch of existing shape and dimensions made of cotton/micofiber suitable for water filter operation complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair membrane hydramem for water treatment(RO plant) suitable for pressure of 15.5 bar size : 4040/8040 made of Poly-amide Composite for Working Pressure of 10-12 Kg complete all as specified and as directed by Engr-in-charge
Supply and Fix in repair 1.5 KW Single Phase Reverse Osmosis Control Panel, Automatic, Digital type suitable for 230 volts system complete all as specified and as directed by Engr-in-charge.
Supply only Antiscalant chemical 8211, liquid, packed in 25 kg HDPE container complete all as specified and as directed by Engr-in-charge.
rajengineers
Sukhi Electricals
Hirachand Sunderji and co
SURESH ELECTRICALS
MADHAV ENTERPRISE
Sagathiya Builders
Vijay Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .