Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAdmitted-Finance | ₹1.7 L | L1 | Admitted-Finance |
| 2 | L2₹1.8 LAdmitted-Finance | ₹1.8 L | L2 | Admitted-Finance |
| 3 | L3₹1.8 LAdmitted-Finance BHAGWATI NAGAR JAMMU | ₹1.8 L | L3 | Admitted-Finance |
| 4 | L4₹1.8 LAdmitted-Finance MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹1.8 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical BHAGWATI NAGAR JAMMU | - | - | Rejected-Technical AS PER E NIT |
| Sl No | Description | Qty | Unit | GANPATI ELECTRICAL AND MECHANICAL WORKS L4 | PERFECT ELECTRICAL WORKS L3 | R M ENTERPRISES L2 | VEE AUTO TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Complete Cleaning servicing of VRV units of air conditioning system installed at terrace of New Emergency Block of GMCH, Jammu by way of disconnecting all the incoming electrical connections and then chemical wet servicing for heating effectiveness of the whole unit and including all outdoor unit, indoor units, heating coils servicing, electrical servicing, greasing/oiling of motors etc. The job also includes identification of faults in the system i.e gas leakage etc for its further rectifications and also repairing thr damaged pipes by copper brezing method wherever required so as to make the complete system fully functional in the interest of patient care. The job further includes Complete cleaning/servicing and chemical cleaning of the evaporater/ heating coil by spraying chemical cleaner over the coil surface using jet cleaner pump on both sides of coil for at least 20 minutes and then spraying the coil with fresh water till the foam goes away or till the chemical is washed off and the cleaning process is repeated till the fins and cooling coil are totally cleaned. . Checking the refrigeration control system for operation and adjusting the settings and Checking the refrigeration system, motor and starters for performance and ensuring healthy condition of the plant.. Overhauling of all the required components of the equipment at site or in workshop as and when required. The job also involves replacement of the overheated/burnt/damaged MNX-A2-06 No’s, VSP Single phase preventer-03 No’s with new ones and also replacement of all the damaged wiring in the VRV units . The job further includes repair of control units of VRV’s wherever required The Job also involves repeated cleaning /servicing of all the units as and when required and also cost of technician when required throughout the season as per the recommendation and instructions of the site Engineer. Complete job includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials & works required for execution of job . | 12 | nos. | 0.02 ₹1.8 L | 0.02 ₹1.8 L | 0.02 ₹1.8 L | 0.02 ₹1.7 L |
Tender Value
₹1.8 L
EMD Value
₹4,000
Closing Date
8 Dec 2025, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Complete Cleaning Servicing of VRV Units and allied works for upcoming winter Season installed at New Emergency Block of GMCH Jammu
2025_PWDJK_296971_2
MHDJ/e-NIT 279 of 2025-26
Open Tender
Repair and Maintenance Services
10 days
GMCH JAMMU
as per enit
2 documents required · 2 mandatory
₹200
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹4,000
2 Jan 2026
3 Dec 2025
9 Dec 2025
3 Dec 2025
8 Dec 2025
3 Dec 2025
3 Dec 2025 - 8 Dec 2025
Amount
Complete Cleaning servicing of VRV units of air conditioning system installed at terrace of New Emergency Block of GMCH, Jammu by way of disconnecting all the incoming electrical connections and then chemical wet servicing for heating effectiveness of the whole unit and including all outdoor unit, indoor units, heating coils servicing, electrical servicing, greasing/oiling of motors etc. The job also includes identification of faults in the system i.e gas leakage etc for its further rectifications and also repairing thr damaged pipes by copper brezing method wherever required so as to make the complete system fully functional in the interest of patient care. The job further includes Complete cleaning/servicing and chemical cleaning of the evaporater/ heating coil by spraying chemical cleaner over the coil surface using jet cleaner pump on both sides of coil for at least 20 minutes and then spraying the coil with fresh water till the foam goes away or till the chemical is washed off and the cleaning process is repeated till the fins and cooling coil are totally cleaned. . Checking the refrigeration control system for operation and adjusting the settings and Checking the refrigeration system, motor and starters for performance and ensuring healthy condition of the plant.. Overhauling of all the required components of the equipment at site or in workshop as and when required. The job also involves replacement of the overheated/burnt/damaged MNX-A2-06 No’s, VSP Single phase preventer-03 No’s with new ones and also replacement of all the damaged wiring in the VRV units . The job further includes repair of control units of VRV’s wherever required The Job also involves repeated cleaning /servicing of all the units as and when required and also cost of technician when required throughout the season as per the recommendation and instructions of the site Engineer. Complete job includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials & works required for execution of job .
R M ENTERPRISES (BID ID -2660766)
PERFECT ELECTRICAL WORKS (BID ID -2661731)
GANPATI ELECTRICAL AND MECHANICAL WORKS (BID ID -2661994)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_962905.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid