Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.1 LAccepted-AOC CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | ₹17.1 L Quoted ₹17.6 L | 1 | Accepted-AOC Lowest |
| 2 | 2₹18.6 L+₹91,480 (5.19%)Rejected-AOC | ₹18.6 L+₹91,480 (5.19%) | 2 | Rejected-AOC Second lowest |
Tender Value
Refer Docs
EMD Value
₹42,500
Closing Date
26 Sept 2024, 5:15 pmClosed
Managing Director
Managing Director KTDC Corporate Office Mascot Square Trivandrm -695033
Supply installation testing and commissioning of cold room at KTDC Hotel Samudra Kovalam
2024_KTDC_689411_1
AE(E)I/KTDC.EW-TVM/7920/ HS-Kovalam-Cold room/ 2024
Open Tender
Electrical Works
Item Rate
60 days
KTDC Hotel Samudra Kovalam
Reputed manufacturers/Their Authorized agencies, who have executed one similar work with a value not less than 14 Lakhs OR two such works each costing not less than 7 Lakhs. The proof of experience and authorization should be enclosed in the technica
9 documents required · 9 mandatory
₹2,950
₹42,500
29 Mar 2025
12 Sept 2024
28 Sept 2024
12 Sept 2024
26 Sept 2024
12 Sept 2024
Amount
Cold room works
Supply of Condensing & evaporating units suitable for the walk in cold room consisting of freezer room for a storage capacity of 150 Kg of meat at temperature of –20 to –18 deg C and chiller room for a storage capacity of of 200 KG of vegetables at temp of +2 to +8 degree C. The condensing unit is made up of self supporting steel frame with hermetic compressor and air cooled compressor coil, fan motor, electrtical and microprocessor controls etc and complete mounted at suitable position including refrigerant piping and all connections as required of minimum 6 meters. The Housing of the evaporator unit is made up of high quality 304a stainless steel specially designed copper coil, filter, expansion device self lubricated axial fans and consist with all safety controls and power saving flow controls with automatic and electrical de frost controls.
Freezer room- 2m x 4m x 2.4m
Chiller room- 2m x 4m x 2.4m
The Supplier should provide a centralized pre wired electrical control panel for feeding electrical supply to the compressors having individual suitable rating contactor with overload and short circuit protection, single phasing preventer, LED indicators. The panel should have necessary cable entry/ leaving provisions, necessary isolation TP/SP MCBs and ISOLATORS etc complete as required for prevailing standards. KTDC will provide three phase/single supply with in 3m of each cold room and necessary cabling to panel to cold rooms must done by the supplier.The unit is fitted with a micro-processor based digital electronic temperature controller cum indicator for easy readability along with audio-visual alarm system. The controller should have the facility to set temperature and humidity value and also the safety limits for temperature and humidity. An audible alarm should be provided in the event of actual values exceeding the set limits,In the event of failure of the main mechanical refrigeration system or dehumidification device, the switch over to standby system should be automatic with indication of failure of main system.In the event of power failure,module should have delayed start in a sequesnce so that power lines are not loaded.
The supplier should do the necessary internal electrical wiring confirming to relavant standards as required at site including providing vapour proof type light fittings suiting to all temperature ranges with in the cold room with control on outside.
Supply of pre fabricated modular 100 mm PUF insulated sand witched (inside SS 304 and outside PPGI) Panels for the freezer room with corner panels and cam lock.The SS sheet shall have 0.5mm thickness.
Supply of pre fabricated modular 60 mm PUF insulated sand witched (inside SS 304 and outside PPGI) for the chiller room with corner panels and cam lock.The SS sheet shall have 0.5mm thickness.
Supply of 50mm thick PUF slab with bitumen sheet as vapour barrier for floor insulation for chiller room.
Supply of 100mm thick PUF slab with bitumen sheet as vapour barrier for floor insulation for freezer room.
Supply of flush type self closing swing 60 mm PUF insulated door (900 x 2000 mm) including door frame of 60 mm thick with SS laminations on inside and outside PPGI with anti condensation door heater, pad lock, posi seal closure, human safety release knob and etc complete as required at site.
Supply of flush type self closing swing 100 mm PUF insulated door (900 x 2000 mm) including door frame of 60 mm thick with SS laminations on bothsides with anti condensation door heater, pad lock, posi seal closure, human safety release knob and etc complete as required at site
Installation testing and commissioning of the cold room including panel erection, flooring, flashings, mounting of indoor & outdoor units, Cu piping, wiring, drain piping, pressure testing, vaccumising, gas charging, testing & commissioning and other electrical hook up, plumbing and drain hook up connection etc. complete in all respect with all required materials etc complete as required at site.
Supply and providing additional Copper Refrigerant piping ( for freezer room) and fitting using brazed joints, complete with required thickness tubular elastomeric nitrile rubber EPDM insulation and finished with glass cloth (microban) . The refrigerant piping shall be adequately sized to take care of the length of piping. Complete piping workmanship to be carried out as per recommended practice. The piping to be vacuum tested and leaktested. Scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using steel hangers, anchors, brackets and supports etc which shall be fixed to the building structure by means of inserts or expansion shields of adequate size and number.
Supply and providing additional Copper Refrigerant piping (For chiller room) and fitting using brazed joints, complete with 19 mm thick tubular elastomeric nitrile rubber EPDM insulation and finished with glass cloth (microban) . The refrigerant piping shall be adequately sized to take care of the length of piping. Complete piping workmanship to be carried out as per recommended practice. The piping to be vacuum tested and leaktested. Scope includes all refrigerant pipes shall be properly supported and anchored to the building structure using steel hangers, anchors, brackets and supports etc which shall be fixed to the building structure by means of inserts or expansion shields of adequate size and number.
Supply and providing hooter and alarm for freezer room for the safety purpose
Supply and providing PVC strip curtain freezer garde for freezer room .
Supply of Storage racks suitable for the cold room for storing Vegetables/ Meat as required as per standards made out of food grade stainless steel (SS304) sheets angles , channels and perforated plates of 1.25 mm thickness.The individual racks provided shall have 4 shelves.
Electrical works
Supply and providing 25 A DP MCB isolator of good quality and reputed make in an enclosure.
Supply and providing 32 A Four pole MCB isolator of good quality and reputed make in a suitable enclosure.
Civil works
Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size).
EMMAR APPLIANCES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .