Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.9 LAccepted-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | 1 | Accepted-AOC Accepted | |
| 2 | 2₹41.2 L+₹1.3 L (3.23%)Rejected-AOC SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | 2 | Rejected-AOC rejected | |
| 3 | 3₹44.3 L+₹4.4 L (11.0%)Rejected-Finance COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | 3 | Rejected-Finance Rate high | |
| 4 | 4₹47.4 L+₹7.5 L (18.7%)Rejected-Finance JOGENDRA NAGAR AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | 4 | Rejected-Finance Rate high | |
| 5 | Rejected-Technical MALBASSA WEST DALAK AMARPUR GOMATI TRIPURA 799104 | GOMATI | TRIPURA | 799104 | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | ADHIR DEBNATH L1 | SUDHANGSHU BHATTACHARJEE L4 | Asish Debnath L3 | RANJAN BHATTACHARJEE L2 |
|---|---|---|---|---|---|---|---|
| 1.00Supply of the following materials :- | |||||||
| 1.01 | 9 mtr long PCC Pole | 32 | Nos | 6,000 ₹2,26,560 | 6,000 ₹2,26,560 | 5,200 ₹1,96,352 | 5,000 ₹1,88,800 Lowest |
| 1.02 | Stay set complete (HT) | 31 | Set | 500 ₹18,290 | 120 ₹4,389.6 Lowest | 650 ₹23,777 | 1,000 ₹36,580 |
| 1.03 | Stay wire, GI( stranded) | 155 | KG | 50 ₹9,145 | 30 ₹5,487 Lowest | 60 ₹10,974 | 80 ₹14,632 |
| 1.04 | Stay insulator(11KV) | 31 | No | 30 ₹1,097.4 | 10 ₹365.8 Lowest | 45 ₹1,646.1 | 50 ₹1,829 |
| 1.05 | 11KV, Pin insulator (Polymer) | 63 | No. | 150 ₹11,151 | 100 ₹7,434 Lowest | 175 ₹13,009.5 | 225 ₹16,726.5 |
| 1.06 | 11 KV Disc Insulator (Polymer) | 72 | No. | 150 ₹12,744 | 100 ₹8,496 Lowest | 180 ₹15,292.8 | 200 ₹16,992 |
| 1.07 | 11 KV Disc fittings | 72 | set | 250 ₹21,240 | 120 ₹10,195.2 Lowest | 200 ₹16,992 | 300 ₹25,488 |
| 1.08 | MS Channel (75*40*40*6) (Galvanised) | 466 | kg | 60 ₹32,992.8 | 40 ₹21,995.2 Lowest | 60 ₹32,992.8 | 80 ₹43,990.4 |
| 1.09 | MS Angle (65*65*6) (Galvanised) | 432 | kg | 60 ₹30,585.6 | 40 ₹20,390.4 Lowest | 60 ₹30,585.6 | 80 ₹40,780.8 |
Tender Value
₹59.2 L
EMD Value
₹1.2 L
Closing Date
8 Sept 2025, 5:30 pmClosed
DGM, ED Kamalpur
Office of the DGM, ED Kamalpur, TSECL, Dhalai Tripura
Renovation and new construction of 3 KM 11 KV line UG 2 KM Overhead 1KM of dedicated Shibbari Feeder for providing dedicated Power Supply to 3 nos BFL Sonarai, Shibbari and Marachara under ESD KAmalpur of ED Kamalpur
2025_POWER_65143_1
DGM/KMP/25-26/06 Dated 01/09/2025
Open Tender
Electrical Works
Turn-key
120 days
ED Kamalpur
As per Bid document
3 documents required · 3 mandatory
₹4,000
₹1.2 L
ED Kamalpur
29 Oct 2025
1 Sept 2025
8 Sept 2025
1 Sept 2025
8 Sept 2025
2 Sept 2025
2 Sept 2025 - 2 Sept 2025
2 Sept 2025
Amount
Supply of the following materials :-
9 mtr long PCC Pole
Stay set complete (HT)
Stay wire, GI( stranded)
Stay insulator(11KV)
11KV, Pin insulator (Polymer)
11 KV Disc Insulator (Polymer)
11 KV Disc fittings
MS Channel (75*40*40*6) (Galvanised)
MS Angle (65*65*6) (Galvanised)
Machine made MS nuts & bolts (A/S) ic washer
MS Flat 50x6 mmfor Stay and Line bkt. Clamp
Design, Engineering, Supply of 11 KV 1250 Amps, 25 KA for 3 Seconds , 350 MVA rupturing Capacity Indoor Vaccum Circuit Breaker Make CGL(for Outgoing Feeder), Complete with 1 Set of CT of ratio 300/1 - 1, Control and Relay Panel Simplex type with 110 Volt DC actuated electrical closing /Tripping Merchanism and internal Wiring to over Current & 1 earth Fault combined micom digital Relay 1 no electromechanical Areva Master Trip Relay Auxiliary relay as reqd , 1 no L& T / Secure make Trivector Meter( Scada complete with Communication facility) 3 Ammeter 1 Volt Meter, 1 CT operated Static KW Meter, with panel bus mounted CT and integral earthing facility including internal arc tested panel Confirming to relavant ISS/IEC as reqd including standard indication facilities.
11 XLPE Cable 3x95 sq mm
HDPE Pipe Pe-100 Grade PN 8 (SDR 17) 110 mm outer dia wall thickness minimum 6.5 mm , maximum 7.3 mm, 6 mtr long
GI Pipe 150 mm outer dia 6 mts long
11 KV HT 4 way (1 incoming and 3 outgoing)outdoor type feeder pillar-kiosk with necessary fitting and structures complete as per requirement
Earthing set
11KV G.O Switch ( 3 Phase ) (Polymer)
11KV D.O Switch ( 3 Phase) (Polymer)
LA (11 KV) (9 KV , 5 KA)
ACSR(6/1/2.59 SQMM)
Erection of the following Materials:-
9 mtr long PCC Pole
Stay Set Complete
2.2 mt.long 75X40X40X6 mm ms channel for DP Line bkt.
Erection of M.S Channel Cross - Arm, 0.3 to 1.2 mtr Long 75X40X40X6 mm (Single Pole Top and Bottom )
Erection of M.S Angle Cross - Arm, 01 to 2.5 mtr Long 65X65X6 mm (Guard Bracket for SP and DP )
11 KV polymer pin insulator.
11 KV single Disc polymer insulator set with fittings
ACSR 6/1/2.59 mm weasel
11 KV GOS Set of 3 (three phase)
11 KV DOF unit set of 3 (three phase.)
Fabrication of MS Channel and angle including holes and other works
Erection, Testing & Comssioning of 11 KV 1250 Amp continuous rated current 350 Amp rupturing capacity Indoor Vacucm Circuit Breaker (for Outgoing Feeder) complete with 1 Set of CT of ratio 300/1-1, Control & Relay panel Simplex type with with 110 Volt DC actuated electrical closing /Tripping Merchanism and internal Wiring to over Current & 1 earth Fault combined micom digital Relay 1 no electromechanical Areva Master Trip Relay Auxiliary relay as reqd , 1 no L& T / Secure make Trivector Meter( Scada complete with Communication facility) 3 Ammeter 1 Volt Meter, 1 CT operated Static KW Meter, with panel bus mounted CT and integral earthing facility including internal arc tested panel Confirming to relavant ISS/IEC as reqd including standard indication facilities.
Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Trench Size:Width-350mm, Hieght- 1200mm / Sand(couhioning): Hieght-250mm, Width- 350mm/Protection: Double layer BricksUpto 120 sq. mm
Mannually digging/drilling horizontally or diagonally direction for road crossing water supply line Telecommunication line Gas Pipe line etc including laying of 64 to 200 mm dia GI pipe direct ito the earth at a depth of minimum 1100 mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engg-in charge
Erection of 4 Way 630 A HT Kiosk/ 11 KV outdoor Type Feeder pillar made of MS Sheet complete with Aluminium Insulator etc as required system and painting MS Angle(50x50x6 10 SWG Busbar HT provided with locking to be filled in structure off and concreting mach leg of kosk in the 1:24 cement 2 er sand 4 jama Bricks 42 mm) & MS fat/40x6 mm) tem code 40 apgregate ith 20mm nominal size, including certering shadering & Disposal of excess excavated soil
Supplying and Making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE alumminium conductor cable of 11 KV grade as required.
Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE alumminium conductor cable of 11 KV grade as required.
T shaped piller for cable ID Marking with caption
Detail survey, Rought alignment etc
Maintaining adequate clearance from overhead live conductors by trimming of tree branches for way leaves
RANJAN BHATTACHARJEE (BID ID -187402)
Asish Debnath (BID ID -187514)
SUDHANGSHU BHATTACHARJEE (BID ID -187672)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .