Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.7 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹40.2 L+₹45,957 (1.16%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹45.3 L+₹5.6 L (14.0%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | Rejected-Technical | - | Rejected-Technical VERIFIED AND NOT ADMITTED. AS NOT ENLISTED IN REQUISITE CATEGORY |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
26 Apr 2022, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER (NAVAL BASE ), NAUSENABAUGH, GANDHIGRAM POST, VISAKHAPATNAM 530005
RENOVATION OF KITCHEN TILES IN CERTAIN QTRS AT E SECTOR DOLPHIN HILL ADDITION AND ALTERATION AT TPW AND AFLOAT OFFICE OF BLDG NO P-14 AT CERTAIN UNIT DOCKYARD AND PROVN OF STAFF ROOM, SAFETY PROTECTION WALL STEPS AMD RAMP TO STAGING ASSEMBLY IN THE C
2022_MES_515635_1
C/8009/22-23/E8 / Token 02 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹94,600
Yes
31 May 2022
29 Mar 2022
28 Apr 2022
29 Mar 2022
26 Apr 2022
12 Apr 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, as in vertical surfaces such as skirting etc, including 10 mm thick screed bed in cement mortor 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of alkali resistant priming coat over one or more coat of wall care putty complete all as specified and directed.
M & L for 50 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in sub base of floor paving etc complete all as specified and directed.
M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, light shade coloured (light shade), tiles, 10 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for PCC/RCC 1:2:4, type B-1, (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, cast in situ including necessary form work complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
Providing and fixing factory made uPVC white colour Sliding window Three track Area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+/-0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 (+/-0.2)mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)
S & F 4.8 mm thick, sheet glass, ordinary quality and glazing with rubber gasket etc in square exceeding 0.5 Sqm in each pane complete all as specified and as directed. (Note: The cost of rubber beads included with the unit quoted rate of respective aluminium shutter)
S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S & F 100 mm size Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
M & L for preparing old decorated surfaces of wall, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of distemper oil emulsion complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated soils exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in walls, retaining walls, ballast walls and the likes any thickness above top of footings including attached pilasters and buttreses complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
S & F high strength corrosion resistantTMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm including form mould, mitred/stopped etc. complete all as specified and as directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in roof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed.
S & F 12mm thick clear glass including necessary itching for logo with arrangement of one double leaf shutter of suitable size (0.75mmx2.1mm) with fixing arrangement of handle in each leaf alongwith non toxic/odourless silicon gel around the junction complete all as specified and directed.
S & F standard size stainless steel patch fitting for side glass panel and glass door including necessary fixing arrangement complete all as specified and directed.
S & F 25x450mm size, stainless steel designer handle, bright matt finished, fabricated type polished complete all as specified and directed.
M & L for granite stone slab (of any type) 18 to 20 mm thick (Table rubbed and polished), machine cut, colour Mexican Red/Ruby Red/Z black/Paerl black etc design/pattern as directed including inlays, borders, margins in two or more colours/shades as in skirting/dado vertical surfaces etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick screed bed in cement mortor 1:4 & cutting, polishing complete all as specified and directed.
M & L for 18mm thick, factory made ready to install, Non-toxic, Lead & Cadmium free, singl;e extruded, water proof, termite proof, fire retardent, excellent screw holding capacity, solid PVC board, one side decorative choice lamination and other side balancing white as in cupboard shutter, fixed to door frame with and including continuous Piano hinges of stainless steel, bright finish or Electrogalvanised and width of flaps 40mm (when open) and stainless steel screw including lipping the cut edges with same materials finish complete all as specified and directed.
M & L for 18mm thick, factory made ready to install, Non-toxic, Lead & Cadmium free, singl;e extruded, water proof, termite proof, fire retardent, excellent screw holding capacity, solid PVC board, one side decorative choice lamination and other side balancing white as in cupboard shelves fixed to and including PVC guide rail and stainless steel screw including lipping the cut edges with same materials finish complete all as specified and directed.
S & F 100 mm size, stainless steel designer pull handle, fabricated type polished complete all as specified and directed.
S & F bold metallic stainless steel letters or alphabetes made out of 22 Guage thick Stainless steel plain sheet of grade 304 plain sheet of suitable width not less than 50mm and depth/thick not less than 20mm based on height of letter (hollow section made to shape by using computerised cutting), height of letter not less than 15 inch in Hindi and Engilish laguages and fixed on granite wall cladding/tiles finished wall elevated from surface complete all as specified and as directed.
S & F 12mm thick, Seamless Calcium silicate designer false ceiling of size 1800x1200mm board made of siliceous and calcareous materials reinforced with cellulose fibre fixed to ceiling section with 25mm long self drilled and tapping screws having Phillips head with under head cutter at 200mm centre to centre including finishing the joints of face board with specially formulated jointed compound and 48mm wide fibre tap to provide seamless finish and including provn of GI frame work for suspended seamless false ceiling comprising of GI ultra perimeter channels of size 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and a web of 27 mm alongwith perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 450 mm intervalss. then suspending GI ultra intermidieate channels of size 45 mm x 0.9 mm thick with two flanges of 15 mm each supported with ultra ceiling angle of width 25mmx10mmx0.55 mm thick fixed to soffit with GI cleat and steel expansion fasteners at 1220 mm intervals, Ultra ceiling section of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the ultra intermidieate channel with the help of connecting clips and in direction perpendicular to the ultra intermidieate channel at 457 mm centres complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for Mild Steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® complete all as specified and directed.
M & L for mild steel round bar 10mm dia and over cut into length, bend to shape required including cranking bending spirally for hoping as in tie bar for fixing chain link fencing complete all as specified and directed.
S & F 1050 mm dia punched tape concertina coil as per IS 4454 with galvanised coating and punched tape material as per IS-513 deep drawn quality with galvanising coating , having medium barbs( barb length: 24+ 1 mm ,Pitch between two barbs 35+ 1mm ) fixed in position and secured to both sides of shaped angle iron post , stretched to a length of 6 to 8 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall fixed over angle iron ‘Y’ shaped, Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) to achieve 1050 mm dia as in fencing to steel post and to another coil /MS ribs including fixing with special galvanised fasterners such as 'J' clips , 'C' clips , U clips all as specified and directed (Note : After stretching the coil, the length of the compound wall on which it has been stretched shall be considered for measurement.)
S & F Galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete as specified and directed. (Note : Each line of wire to be measured)
M & L for Broken glass coping on top of wall in 25mm layer of cement mortar (1:3) with a rounded or weathered finish and before the mortar has set, glass (of bottle or thick glass) broken to approximately 63mm gauge, shall be firmly embedded at the rate of 10 Kg of glass per square metre of rendered surface, jogged edges of the glass being left projecting complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/disintegrated rock complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard rock complete all as specified and as directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for Antitermite treatment by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for Antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for Antitermite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for Antitermite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M & L for 10 mm thick screed bed in CM 1:4 mixed with WPC as per manufacturer's instructions over 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate), as in levellig course, Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grooving & inserting in parapt wall all as per manufacturers instructions and applying two coats of aluinium paint over a coat of primer over the top surfaces complete all as specified and as directed. (Note: WPC shall be measured and paid seperately)
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction over one or more coat of wall care putty to a smooth surface complete all as specified and directed.
M & L for moorum/red bajri filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
S & F Aluminium powder coated windows frame with shutters sliding pattern consisting of three tracked frame and 03 shutters (2 shutters glazed and 01 shutter gauge) using standard medium weight section of weight not less than 0.55 Kg/RM including glazing with 5 mm thick sheet glass fixed with suitable EPDM rubber beading and one shutter with stainless steel mosquito proof wire cloth of 0.36mm nominal dia wire and average aperture 1.4mm) and 10mm dia aluminium decogrill (DG-102) and necessary hanbdles/locking arrangements for shutter of Jindal (or equivelant) sections Window Frame ( Top & Sides) : 21137, Bottom L 20977, Window shutters : Top & Bottom : 20567, Sides : 20738 complete all as specified and as directed.
Material and labour for 23-25 mm thick pre-polished coloured and chemically treated cement concrete chequered tiles, glossy finish, of size 300x300mm, ISI marked (IS-13801-1993), set, jointed in neat cement slurry and pointed with white cement mixed with pigment to match over and including 20mm thick scread bed in cement mortar 1:6 complete all as specified and directed
M & L for Providing precast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including sunken type metal GI boxes fo suitable size including Modular white coper plate for fixing modular type type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 102 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 102 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 102 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 102 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch, AC 230V, 50HZ, complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F Telephone jack delux with shutter, 2 line with metal box complete all as specified and as directed.
S & F Distribution Board, TPN, 4 way, 415V, Double door with IP 54 protection complete all as specified and as diretced complete all as specified and directed. (Make: Legrand cat part No. 5076 90 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 42 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 40 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB, TPN 40-63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Legrand Cat part No. 4086 81 to 83 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing MCB TP, 40-63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed (Make : Legrand Cat part No. 4086 59 to 61 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
S & F 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
S & F energy efficient, low noise, ceiling fan, 1200 sweep, BEE 5 Star Rated with BLDC motor, copper wound conforming to IS-373, ISI marked, suitable for operation on single phase, 240 Volts AC, 50 Hz of approved colour including fan regulator, electronic type, down rod, canopies, 3 Nos blades, shackles, safety rope, hanging clamp, bushes and having power factor >0.94, service value >6.5, power consumption less than 35 Watts, air delivery >215cmm, THD less than 5% with speed control by electronic regulator including connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years onsite replacement manufacturer's warranty)
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed (Make : Havells, Model : Ventil Air DS or equivelant of make as per List of Manufacturer's as approved)
S & F LED 30 Watt, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source, suitable for highlighting architectural features or Area Lighting, Also suitable to rough services/installations and with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length complete all as specified and as directed. (Make: Havell's Cat No. JETA QUANTOPLUSFLP30WLED757SYMLENS or equivelant of make as per list of manufacturer)
S & F Bulkhead designed for modern homes with premium quality diffuser for glarefree light and easy to install snapfit installer, 6.50 W LED 6000 K including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. LHEXCGP7PN5W006 and equivelant model of make as specified in list of manufacturer).
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing & Commissioning, Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built ioniser and plasma filter for better indoor quality with minimum 3 Star Rating and EER 3.2 of capacity 2 TR complete with all connecting pipes and fixing accessories such as bracket etc complete all as specified and directed.
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed.
S & F wall mounted fan made of sturdy engineering plastic complete with speed regulator and wide osciliation control, 400 mm sweep, AC, single phase 230 Volts, 50 Hz, minimum RPM 1200, copper windind complete with all accessories and electric connection complete all as specified and directed (Make : Havells, Model : 'GIRIK', FHWGIMTWHT16 or equivalent model of Bajaj/Usha/ Khaitan/Orient as approved)
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
M & L for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3 core complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
NAVEEN INFRASTRUCTURES
G V REDDY & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .