Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹7.8 L+₹2,326 (0.30%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC Rejected L1 being accepted | |
| 3 | L3₹7.9 L+₹10,925 (1.40%)Rejected-AOC | L3 | Rejected-AOC Rejected L1 being accepted | |
| 4 | L4₹8.5 L+₹67,724 (8.70%)Rejected-AOC | L4 | Rejected-AOC Rejected L1 being accepted | |
| 5 | L5₹8.6 L+₹83,360 (10.7%)Rejected-AOC | L5 | Rejected-AOC Rejected L1 being accepted |
Tender Value
₹10.1 L
EMD Value
₹20,280
Closing Date
24 Jun 2021, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2021_MES_446039_1
GE (ARMY) TVM 9380/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹20,280
Yes
14 Jul 2021
27 May 2021
26 Jun 2021
28 May 2021
24 Jun 2021
10 Jun 2021
28 May 2021 - 9 Jun 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.complete all as directed
Point wiring complete for One light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded, copper conductor in and including non-metalic PVC conduit incl accessories totally concealed in wall, ceiling/roof etc., with modular metal flush boxes of suitable size & modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade, multistranded single core green colour copper conductor for earth continuity connected to earth dolly all as directed NOTE: Cost of modular metal flush boxes with a coat of synthetic enamel paint over a coat of red oxide to steel surface to avoid rust, concealed in wall with suitable white cover plate for mounting switch/sockets, regulator, bell push etc and Cost of cutting chases & making good to distrubed surface with cement mortar, if required any shall be deemed to be included in the quoted rate Make: Havells or equivalent make of Finolex/Nicco/Plaza/Anchor/Polycab/RPG
All as per ser item No. 2 above but for One fan point controlled by one way switch and regulator
All as per ser item No. 2 above but for one 5 Amps outlet on same board with other switches/sockets
All as per ser item No. 2 above but for one 5 Amps socket outlet on independent board.
All as per ser item No. 2 here in above but point wiring with 4.0 Sqmm FRLS cable and 4.0 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
S&F modular switch 1 way 6A, 240 volts, 1 module complete all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F modular switch 1 way 16A, 240 volts, 1 module complete all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan of any sweep all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F modular socket, 6A, 240 volts, 3 pin combined 2 module, ISI marked flush type all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
Point wiring complete for One light point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including PVC casing-capping minimum 25 mm wide with all fittings and accessories such as bends, tees, joints etc. fixed to wall or ceiling with recessed, pressed steel terminal boxes 1.6 mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, unsheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly, all metal parts, such as tube light fittings, fan hook, earth terminal of all socket points etc all as specified and directed NOTE: (a) Pressed steel terminal boxes concealed in wall with suitable 3mm thick laminated sheet cover plate for mounting switch/sockets etc are deemed to be included in the quoted rate (b) Electric fittings/fixtures such as switch, socket, regulator, bell push, etc., shall be measured and paid separately under Schedule item No. 18 to 26 here-in-after. Make: V-Guard or equivalent make of Havells/Plaza/Finolex/MESCab/RRKabel
All as per ser item No. 12 above but for One fan point controlled by one way switch and regulator
All as per ser item No. 12 above but for one 5 Amps outlet on same board with other switches/sockets
All as per ser item No. 12 above but for one 5 Amps socket outlet on independent board.
All as per ser item No. 12 here in above but point wiring with 4.0 Sqmm FRLS cable and 4.0 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
S&F switch piano, flush type, single pole, one way 6 Amp, 240 volt, white or ivory ISI marked, with IP- 20 protection, captive screw, silver cadmium contact with spark shield complete all as specified Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
M&L for stepped type electronic fan regulator, flush type 240 Volts, 50 Hz, suitable for ceiling fan any sweep all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
Fixing only electronic dimmers, flush type on the exiting phenolic laminated sheet etc all as directed NOTE: Schedule 'B' store to be issued to the contractor for fixing
S&F switch socket outlet 5 pin, 5 Amps, 240 volts complete all as specified Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F switch socket combination 2 in 1, 5 pin, 6 Amps flush type 240 volts, white or ivory ISI marked complete all as specified Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F switch socket combination 2 in 1, 6/16 Amps flush type, universal, 240 volts, white or ivory ISI marked complete all as specified Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal complete all as specified Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
S&F Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed Make: Anchor or equivalent make of Havells/Legrand/Cona/Crabtree
M&L for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, TPN 4 way, 415 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCB SPN, SP etc, including taking down existing unserviceable one and removing from site complete all as specified and directed Make: Legrand or equivalent of L&T/ABB/Havells/Siemens/Schneider/Indoasian
All as per ser item No. 25 above but for SPN 12, 240 volts grade with 200 Amps insulated rated busbar
All as per ser item No. 26 above but for SPN 8 way
S & F MCB single pole 5 to 32 Amps, 240 volt, 10 KA, C curve, ISI marked as per IS/IEC-60898-1 2002 including sliding bottom clamp, integrated label holder, sliding shutters, biconnect lower terminals with IP-20 protection complete with connection, testing including taking down old unsv one from the site complete all as directed Make: Legrand or equivalent in L&T/ABB/Havells/Siemens/Schneider/Indoasian
All as per ser item No. 28 above but for MCB single pole and neutral 32 Amps
All as per ser item No. 28 above but for MCB single pole and neutral 40 to 63 Amps
All as per ser item No. 28 above but for MCB triple pole and neutral 40 to 63 Amps
Supply and fixing sub main wiring with 2 runs of 6.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC FRLS conduit, medium grade, ISI marked, 20/25mm bore with conduit fittings and accessories concealed in wall/ceiling/floor including 1 run run of 6.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete. NOTE: Two runs of 6.0 sqmm copper cable and one run of 6.0 sq mm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length Make: V-Guard or equivalent make of RRKabel/Finolex/Plaza/Havells/MESCab
All as per ser item No. 32 above but for sub main wiring with 2 run of 4 sqmm & 1 run of 4 sqmm as earth wire
Supply and laying or fixing or passing through and including GI pipe, 1100 volts grade heavy duty stranded conductor cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheated 10 sqmm 2 core nominal cross section in service connections complete all as directed Make: V-Guard or equivalent make of Finolex/RRKabel/Plaza/Havells/MESCab
Dismantling and taking down carefully existing serviceable tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for keeping in safe custody, refixing the same at its original location after wiring, including making electric connection from connector to light fittings & connecting up, testing the same for smooth operation complete all as specified and directed
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells or equivalent make of Philips/Bajaj/Wipro/Osram/GE
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed
Taking down carefully existing serviceable exhaust fan, ceiling cable end, etc., removing the fan for keeping in safe custody, fixing the exhaust fan connecting up after rewiring, including making electric connection from ceiling rose/connector to fan complete all as directed
M&L for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earthwire 4mm diameter by means of GI Bolts, Nuts, check nuts and washers including earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab 50 mm thick with 8 mm CTD bars reinforcement both ways at 140 mm centre to centre with two handles, 20 mm dia GI pipe medium grade for watering pipe , wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm and 15 mm dia light grade GI pipe for protection of earth wire from earth plate to MCB DB including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr and testing on completion complete all as shown in electrical plate No-3 as specified and directed.
JEETH CONSTRUCTION
AKASH CONSTRUCTIONS
GRAND COOL SOLUTIONS
General Engineering and Constructions
SUJAN
S L ELECTRICAL WORKS
BIN TECH ELECTRICALS AND ELECTRONICS ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .