Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.4 LAccepted-AOC H 27 UPPER GROUND FLOOR MOHAN GARDEN UTTAM NAGAR NEW DELHI DELHI 110059 | WEST | DELHI | 110059 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹22.0 L+₹90,931 (4.30%)Rejected-AOC D 3 195 CHITRAKOOT NAGAR AJMER ROAD JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | 2 | Rejected-AOC L-2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.4 L
EMD Value
₹46,730
Closing Date
17 Oct 2020, 6:00 pmClosed
EE(E),Jodhpur
Executive Engineer (E), BSNL,Electrical Division, Ist Floor, Administrative Building, Pal Road, Subhash Nagar, Jodhpur-342008. (Phone No. 0291-2757833, Mob -9413394902)
SITC of 3 Nos. x 7 TR Microprocessor based High Precision type AC units with Air Cooled Condensers including Comprehensive Maintenance for NFS Site Utterlai-2, Barmer ( Rajasthan).
2020_BSNL_58598_1
07/EE(E)/BSNL/ED/JPR/2020-21( 07/SE(E))
Open Tender
Air-Conditioner
Item Rate
90 days
Utterlai
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹46,730
11 Aug 2021
26 Sept 2020
19 Oct 2020
26 Sept 2020
17 Oct 2020
26 Sept 2020
Amount
SUB HEAD - I (SITC of HPAC)
PART ‘A’ (SUPPLY ITEM)
Supply of 7 TR (sensible cooling capacity) Microprocesser based high Precision Airconditioning unit with Air Cooled condensers complete with backward curved evaporator fan directly driven by electronically commutated (EC) motor complete as per detailed specifications enclosed i/c frieght/loading/unloading and forwarding. (The 7 TR HPAC unit will be supplied as per PROTOTYPE approval conveyed by BSNL,Corporate Office (Electrical) New Delhi (Upward/ Downward flow as per site requirment)
Make of Precision AC :- Any make approved by BSNL, Corporate Office (Electrical) New Delhi for 7 TR HPAC, valid as on the last date of submission of bids
PART "B" (ITC & MISCELLANEOUS ITEMS)
Installation, testing and commissioning of above 7TR (sensible) HPAC Package indoor and outdoor units on existing frame, pressure testing, supplying and charging the referigerant R-22/R-407C/R410A i/c acceptance testing as per NIT etc complete as reqd.
7 TR (Sensible) High Precision AC Package unit
a) The hot gas refrigerant line shall be insulated inside conditioned area with high quality insulating material, nothing extra shall be paid on this account.
b) The MS Structure for outdoor units shall be installed on minimum size 300mm x 300mm x 300mm PCC block with 25mmx25mmx3mm angle iron on edges, nothing extra shall be paid on this account. However, the M.S. Structure for outdoor unit / Indoor unit (if required) shall be paid extra vide item No.6 of Part-"B" of SH-I.
c) Each outdoor and indoor unit shall be installed on 12 nos. AVM pads (Rubber pad), nothing extra shall be paid on this account.
Supply & fixing of the following sizes 18 gauge ( 1.2 mm) copper referigerant piping with all accessories cutting, bending, jointing, brazing etc for hot gas and liquied lines on the existing MS perforated tray including insulating the refrigerent lines inside AC area with suitable fire retardant polyethylene etc complete as reqd as per specification attached.
size 1-1/8" single run
size 7/8" single run
size 5/8" single run
Supplying and laying of following sizes of PVC insulated PVC Sheathed copper conductor armoured cable of 1.1 KV grade conforming to relevant I.S. specifications on wall/ existing trench/ existing MS perforated tray (with saddles) i/c interconnections, end termination, gland,lugs etc. complete as reqd. .
4 x 2.5 sqmm
Providing plumbing work for humidification circuits and drainage requirements i/c supply of GI pipes, pipe fittings such as bends, reducers, elbows, tees, unions, flanges etc for water connection of various components of the system, painting etc. complete as required.
40mm dia GI pipe (Medium class)
20mm dia GI pipe (Medium class)
Providing MS structure for outdoor / Indoor units made out of solid channels / angles/flat i/c cutting, welding , painting etc as reqd.
Providing and fixing 25 mm x 5 mm GI strip for loop earthing from package unit to condenser unit on the existing cable tray/ wall etc as required.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M S suspenders including bolts & nuts, painting of suspenders etc complete as required.
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
SUB HEAD - II (Comprehensive Maintenance)
Comprehensive maintenance of 7 TR microprocessor High Precision package AC unit including all items covered under Part-"A" & Part-"B" of Sub Head-I which include routine, preventive & breakdown maintenance i/c supply of consumables, repair / replacement of wornout items with minimum down time and warrantty & guarantee of repaired / replaced items & as per specifications/ conditions of contract & as per the details given in relevent sections by deploying the required staff including specialized man power and by arranging required spares, refrigerant gas, tools and plant etc to keep AC unit & connected equipments operational upto the required standards complete as required. Note- 1. Operation of package AC units is not included in this item.
1st Year (Covered under Gurantee period) (Qty = 3 Pkg. X 12 Months)
2nd Year (Qty = 3 Pkg. X 12 Months)
3rd Year (Qty = 3 Pkg. X 12 Months)
4th Year (Qty = 3 Pkg. X 12 Months)
5th Year (Qty =3 Pkg. X 12 Months)
6th Year (Qty = 3 Pkg. X 12 Months)
7th Year (Qty = 3 Pkg. X 12 Months)
Acme Engineering Systems
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .