Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.7 LAdmitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Admitted-Finance | |
| 2 | L2₹66.9 L+₹4.2 L (6.77%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BHAT ENGINEERING WORKS L1 | M/S LADAKH TRADERS L2 |
|---|---|---|---|---|---|
| 1.00Supply Installation testing and commissioning of radiator panels along with circulation pipes with insulations, specialized valves, including construction of Operator room | |||||
| 2.00Hot Water Radiators Replacement of Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C , complete with Top grilles and side covers as standard along-with inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC | |||||
| 3.00 | 3000 Kcal/Hr (Type 33) | 30 | No | 23,500 ₹7,05,000 Lowest | 24,000 ₹7,20,000 |
| 4.00 | 4000 Kcal/Hr (Type 33) | 20 | No | 27,500 ₹5,50,000 Lowest | 27,900 ₹5,58,000 |
| 5.00MS ERW pipe (resin bonded fiber glass insulation) Replacement of blocked MS pipes C-class pipe as per IS-1239 & IS 3589 pipe of following nominal size with necessary clamps, vibration isolators and fitting (but excluding valves, stationers, gauges etc). duly insulated with 80kg/cum design resin bonded fibre glass or 144 kg/cum mineral wool (non combustible) pipe section insulation covered with alyer of 120gm/sqm polythene sheet (vapor barrier) and finally applying 0.63 aluminum sheet cladding complete with type3, grade 1 roofing felt strip at joints and repair to the damage to building etc as per specifications as required. Including valves, strainers as per requirement. | |||||
| 6.00 | 1/2” DIA | 120 | RM | 400 ₹48,000 Lowest | 425 ₹51,000 |
| 7.00 | 3/4 “DIA | 100 | RM | 580 ₹58,000 Lowest | 600 ₹60,000 |
| 8.00 | 1” DIA | 100 | RM | 700 ₹70,000 Lowest | 720 ₹72,000 |
| 9.00 | MS ERW pipe (resin bonded fiber glass insulation) along with MS GI casing pipe of required dia. to be laid under trenches at depth of 450mm below ground level at cement concrete block at c/c 3mtr. | 80 | RM | 700 ₹56,000 Lowest | 715 ₹57,200 |
| 10.00 | Providing and fitting of MS Mixing tank of 3500 liters capacity | 1 | Job | 2,85,000 ₹2,85,000 Lowest | 2,95,000 ₹2,95,000 |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
23 Oct 2023, 2:00 pmClosed
EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL
Office of Executive Engineer Mech Div Kargil
Up gradation of heating system GNM School Kurbathang Kargil
2023_PWD_11496_1
MDK/e-NIT/22 of 2023-24
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
30 days
GNM Hospital Kurbathang Kargil
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹1.1 L
Office of Executive Engineer Mech Div Kargil
20 Nov 2023
19 Oct 2023
24 Oct 2023
19 Oct 2023
23 Oct 2023
19 Oct 2023
21 Oct 2023
Amount
Supply Installation testing and commissioning of radiator panels along with circulation pipes with insulations, specialized valves, including construction of Operator room
Hot Water Radiators Replacement of Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C , complete with Top grilles and side covers as standard along-with inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC
3000 Kcal/Hr (Type 33)
4000 Kcal/Hr (Type 33)
MS ERW pipe (resin bonded fiber glass insulation) Replacement of blocked MS pipes C-class pipe as per IS-1239 & IS 3589 pipe of following nominal size with necessary clamps, vibration isolators and fitting (but excluding valves, stationers, gauges etc). duly insulated with 80kg/cum design resin bonded fibre glass or 144 kg/cum mineral wool (non combustible) pipe section insulation covered with alyer of 120gm/sqm polythene sheet (vapor barrier) and finally applying 0.63 aluminum sheet cladding complete with type3, grade 1 roofing felt strip at joints and repair to the damage to building etc as per specifications as required. Including valves, strainers as per requirement.
MS ERW pipe (resin bonded fiber glass insulation) along with MS GI casing pipe of required dia. to be laid under trenches at depth of 450mm below ground level at cement concrete block at c/c 3mtr.
Providing and fitting of MS Mixing tank of 3500 liters capacity
Providing and fitting 0f Expansion tank HDPE 1000 liters capacity
Providing and filling of Coolant (Servo /IOC)
Aluminum cladding to the supply and return pipes
Supply installation testing commissioning of Hot water generator (Boiler) Stand by capacity 6lac kcal/hour the job also includes the foundation block for the boiler as per site requirement.
Supply, Installation, Testing and Commissioning of AC 1.5 Ton Hot & Cold . The Jobs includes Transformer of required specification electric cable and other accessories required for its installation at site.
Provision for construction of operator room: This job involves the construction of well furnished carpeted thermo cool wooden floor operator rooms of RCC foundation Aluminum framed structure with insulation of room size 12’x14 ,Kitchen size 8’x10’ , Bathroom of size 6’x6’ , a fully-equipped bathroom featuring premium tiles and plumbing, Refrigerator,(,205 Ltr), 01 No, LCD TV 42” 01 No.(LG,Sony,Samsang),Water Purified Kant Aro, =02 Nos, Induction Heater 02 Nos, complete Kitchen sets and comprehensive electrification , geaser the job also includes septic tank and kitchen soakage pit .Complete electrification of the plant room operator rooms and tailing to the of floor of the plant room.
M/S LADAKH TRADERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .