| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAdmitted-Finance | ₹1.1 L | L1 | Admitted-Finance |
| 2 | L2₹2.3 LAdmitted-Finance GATHA BHADERWAH DISTRICT DODA P O UDRANA J K PIN 182221 | DODA | JAMMU AND KASHMIR | 182221 | ₹2.3 L | L2 | Admitted-Finance |
| 3 | L3₹2.5 LAdmitted-Finance | ₹2.5 L | L3 | Admitted-Finance |
| 4 | L4₹2.9 LAdmitted-Finance | ₹2.9 L | L4 | Admitted-Finance |
| 5 | L5₹4.7 LAdmitted-Finance | ₹4.7 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S VAARIS ENTERPRISE L8 | M/S GURUJI ELECTRICAL ENTERPRISES L7 | TOHEED ALAM L10 | Noor Hussain and Sons L1 | M/S SIGMA CONSTRUCTION L12 | MS AMIR KHAN AND BROTHERS L9 | M/s GCS Associates L3 | M/S DAYAL BUILD TECH L11 | M/S KUNDAL ELECTRICAL WORKS AND SUPPLIERS L5 | M/S A A ENTERPRISES L13 | M/S SALARIA ENTERPRISES L6 | MAHAVEER ENTERPRISES L4 | M/S APR CONSTRUCTIONS L12 | Dinkum Enterprises L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Transmission line S/C and D/C :- ( Including carriage of T&P from stores and Shutdown Factor) | |||||||||||||||||
| 1.01 | Checking and tightening of jumpers | 1 | Per Jumper | 6,202 ₹6,202 | 6,200 ₹6,200 | 5,000 ₹5,000 | 2,900 ₹2,900 | 1,01,000 ₹1.0 L | 2,900 ₹2,900 | 1,600 ₹1,600 | 1,00,000 ₹1 L | 6,000 ₹6,000 | 1,05,000 ₹1.1 L | 6,100 ₹6,100 | 1,600 ₹1,600 | 1,01,000 ₹1.0 L | 1,325 ₹1,325 |
| 2.01 | Fixing of vibration damper on earthwire/ACSR Conductor | 1 | No | 4,202 ₹4,202 | 4,200 ₹4,200 | 4,000 ₹4,000 | 120 ₹120 | 1,01,000 ₹1.0 L | 2,600 ₹2,600 | 1,400 ₹1,400 | 1,00,000 ₹1 L | 4,000 ₹4,000 | 1,05,000 ₹1.1 L | 4,100 ₹4,100 | 1,200 ₹1,200 | 1,01,000 ₹1.0 L | 900 ₹900 |
| 3.01 | Replacement of damaged disc Insulators | 1 | No | 6,205 ₹6,205 | 6,200 ₹6,200 | 6,000 ₹6,000 | 6,000 ₹6,000 | 1,01,000 ₹1.0 L | 4,000 ₹4,000 | 3,500 ₹3,500 | 1,00,000 ₹1 L | 6,000 ₹6,000 | 1,05,000 ₹1.1 L | 6,100 ₹6,100 | 4,000 ₹4,000 | 1,01,000 ₹1.0 L | 2,500 ₹2,500 |
| 4.01 | Replacement of Tension string of insulators | 1 | No | 18,105 ₹18,105 | 18,100 ₹18,100 | 10,000 ₹10,000 | 5,400 ₹5,400 | 1,01,000 ₹1.0 L | 3,500 ₹3,500 | 13,000 ₹13,000 | 1,00,000 ₹1 L | 18,000 ₹18,000 | 1,05,000 ₹1.1 L | 18,000 ₹18,000 | 4,000 ₹4,000 | 1,01,000 ₹1.0 L | 2,600 ₹2,600 |
| 5.01 | Replacement of Suspension string of insulators. | 1 | No | 15,602 ₹15,602 | 15,600 ₹15,600 | 10,000 ₹10,000 | 4,300 ₹4,300 | 1,01,000 ₹1.0 L | 5,000 ₹5,000 | 12,000 ₹12,000 | 1,00,000 ₹1 L | 15,000 ₹15,000 | 1,05,000 ₹1.1 L | 15,500 ₹15,500 | 6,000 ₹6,000 | 1,01,000 ₹1.0 L | 9,600 ₹9,600 |
| 6.01 | Replacement of damaged jumpers | 1 | per jumper | 6,202 ₹6,202 | 6,200 ₹6,200 | 5,000 ₹5,000 | 1,900 ₹1,900 | 1,01,000 ₹1.0 L | 4,600 ₹4,600 | 2,600 ₹2,600 | 1,00,000 ₹1 L | 6,000 ₹6,000 | 1,05,000 ₹1.1 L | 6,100 ₹6,100 | 2,400 ₹2,400 | 1,01,000 ₹1.0 L | 2,490 ₹2,490 |
| 7.01 | Replacement of damaged single tension fittings | 1 | No | 10,302 ₹10,302 | 10,300 ₹10,300 | 5,000 ₹5,000 | 5,500 ₹5,500 | 1,01,000 ₹1.0 L | 3,800 ₹3,800 | 8,800 ₹8,800 | 1,00,000 ₹1 L | 10,000 ₹10,000 | 1,05,000 ₹1.1 L | 10,200 ₹10,200 | 7,000 ₹7,000 | 1,01,000 ₹1.0 L | 8,630 ₹8,630 |
| 8.01 | Replacement of damaged double tension fittings | 1 | No | 13,305 ₹13,305 | 13,300 ₹13,300 | 12,000 ₹12,000 | 6,500 ₹6,500 | 1,01,000 ₹1.0 L | 4,500 ₹4,500 | 10,000 ₹10,000 | 1,00,000 ₹1 L | 13,000 ₹13,000 | 1,05,000 ₹1.1 L | 13,200 ₹13,200 | 8,000 ₹8,000 | 1,01,000 ₹1.0 L | 8,200 ₹8,200 |
| 9.01 | Replacement of damaged single suspension fittings | 1 | No | 10,305 ₹10,305 | 10,300 ₹10,300 | 6,000 ₹6,000 | 5,600 ₹5,600 | 1,01,000 ₹1.0 L | 4,600 ₹4,600 | 7,400 ₹7,400 | 1,00,000 ₹1 L | 10,000 ₹10,000 | 1,05,000 ₹1.1 L | 10,200 ₹10,200 | 6,000 ₹6,000 | 1,01,000 ₹1.0 L | 6,900 ₹6,900 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
2 May 2026, 2:00 pmClosed
Executive Engineer TLMD-I Jammu
Office of the Executive Engineer TLMD-I Jammu
Rate contract for preventive routine breakdown maintenance of 132KV transmission lines falling under the jurisdiction of TLMD1 Janipur Jammu
2026_PDD_307647_1
TLMD-I/J/01 of 2026-27 dated 08.04.2026
Open Tender
Repair and Maintenance Services
365 days
Under the Jurisdiction of TLMD1 Janipur Jammu
Refer SBD
3 documents required · 3 mandatory
₹2,000
Executive Engineer TLMD-I Janipur Jammu
₹30,000
18 Jun 2026
10 Apr 2026
4 May 2026
10 Apr 2026
2 May 2026
10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Transmission line S/C and D/C :- ( Including carriage of T&P from stores and Shutdown Factor) | ||||||
| 1.01 | Checking and tightening of jumpers | - | Per Jumper | - | - | item1 |
| 2.01 | Fixing of vibration damper on earthwire/ACSR Conductor | - | No | - | - | item2 |
| 3.01 | Replacement of damaged disc Insulators | - | No | - | - | item3 |
| 4.01 | Replacement of Tension string of insulators | - | No | - | - | item4 |
| 5.01 | Replacement of Suspension string of insulators. | - | No | - | - | item5 |
| 6.01 | Replacement of damaged jumpers | - | per jumper | - | - | item6 |
| 7.01 | Replacement of damaged single tension fittings | - | No | - | - | item7 |
| 8.01 | Replacement of damaged double tension fittings | - | No | - | - | item8 |
| 9.01 | Replacement of damaged single suspension fittings | - | No | - | - | item9 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
Tendernotice_2.pdf
PDF • 0.80 MB
BOQ_997939.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid