Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹9.1 L+₹73,671 (8.85%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹9.5 L+₹1.2 L (14.1%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance Higher Bid | |
| 4 | Rejected-Technical 11 CROOKED LANE KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | - | Rejected-Technical Documents are not in order |
Tender Value
₹9.8 L
EMD Value
₹19,501
Closing Date
4 Dec 2023, 2:00 pmClosed
EE, South 24 Pgs. Elect. Divn.
57/2, Diamond Harbour Road, Kolkata-700023
Proposed Level -III Trauma Care Centre at Diamond Harbour Govt. Medical College and Hospital in the District of South 24 Parganas - Electrical Works -SITC of AC.
2023_WBPWD_600134_1
WBPWD/EE/S24PED/eNIT44/2023-24
Open Tender
A/C ORG
Item Rate
15 days
Diamond Harbour Govt. Medical College
Please refer Tender documents.
4 documents required · 4 mandatory
₹19,501
South 24 Parganas Electrical Division
9 Jan 2025
6 Nov 2023
6 Dec 2023
6 Nov 2023
4 Dec 2023
10 Nov 2023
10 Nov 2023
Amount
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 6.6 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Daikin/Mitsubishi Electric]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe(as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm ,3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Note: 1) All the above rates should be quoted inclusive of all taxes & duties, District charges and LWC as applicable, with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) The Agency must procure the materials from the manufacture/OEM or their authorised sales Channel so that the standard warranty/support of the manufacturerer/OEM becomes applicable to the product to be delivered and installed by them. Documents that authenticate such procurement from the manufacturer/OEM or from their authorised sales Channel and standard warranty/support should be sent from the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. If any refubrished materials are supplied and installed, penal action will be taken as per existing rule. Before execution of the work the prospective bider has to submit layout drawing as per design of OEM dully approved by the OEM. 3) Total is rounded off to the nearest rupees.
RAMKRISHNA ELECTRONICS (BID ID -4372581)
Lyric International (BID ID -4317719)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .