Loading…
Loading…
Tender Value
₹1.3 L
EMD Value
₹3,177
Closing Date
3 Sept 2026, 6:00 pm6d left
AEE
PWD Electrical Sub Division Tvpm
DEPOSIT-Providing additional Electrical works in the V H S Exam section and HS Exam section in Top floor at Pareekshabhavan Poojappura,TVPM-AC works in HSE Joint director room and server room-Electrical AC Work
2026_PWD_864780_3
ESDT/ET-85/2026-27
Open Tender
Electrical Works
Percentage
60 days
PWD Electrical Sub Division Tvpm
please refer tender documents
5 documents required · 5 mandatory
₹555
₹3,177
24 Aug 2026
24 Aug 2026
5 Sept 2026
24 Aug 2026
3 Sept 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of Air conditioner units | |||||
| 1.001 | OD62037/2026-2027:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 5 or above rated inverter type Hi-wall split air conditioner unit Super quiet (Sound less than 40 db) with capable of operation on long mode to make air flow with 4 vanes, computerized demystification, step vane controlled swing, operating on suitable green refrigerant gas with copper material coil type condensing and evaporating units capable for cooling, microprocessor control with cordless remote control including etc. The indoor and outdoor unit fixed on wall a with suitable size factory made powder coated metal stand/threaded rod, connected with nitrile rubber insulated copper pipe with control /power cable (minimum 3 meter) and clamped on wall using metal saddle after proper insulation with non-adhesive tape and giving connection as required, making good the damages and testing and commissioning entire unit. Make: Daikin/Mitsubishi/ Carrier/ Bluestar/Panasonic:- 1.5TR single phase Inverter split A/C unit | - | each set | 60,276.3 | - |
| 1.002 | OD62193/2026-2027:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 5 or above rated inverter type Hi-wall split air conditioner unit Super quiet (Sound less than 40 db) with capable of operation on long mode to make air flow with 4 vanes, computerized demystification, step vane controlled swing, operating on suitable green refrigerant gas with copper material coil type condensing and evaporating units capable for cooling, microprocessor control with cordless remote control including etc. The indoor and outdoor unit fixed on wall a with suitable size factory made powder coated metal stand/threaded rod, connected with nitrile rubber insulated copper pipe with control /power cable (minimum 3 meter) and clamped on wall using metal saddle after proper insulation with non-adhesive tape and giving connection as required, making good the damages and testing and commissioning entire unit. Make: Panasonic / Daikin/Mitsubishi/ Carrier/ Bluestar:- 1.0 TR single phase Inverter split A/C unit | - | each | 51,315.6 | - |
| 1.003 | OD62038/2026-2027:Supply and Fixing of condensate condensate drain UPVC piping as per BIS 4985 with necessary clamps, supports, hangers and fitting such as bend, tees, reducers etc. duly insulated with 9 mm thick chemically cross-linked closed cell nitrile rubber insulation, fire retardant grade as per the drawing and relevant standards.etc complete as per specifications and as required., all complete as per direction of Engineer-in-Charge 25mm dia UPVC | - | metre | 151 | - |
| 1.004 | OD62040/2026-2027:Supply, and fixing of 5/8" +3/8" Refrigerant Copper Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 9 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | - | metre | 1,722.74 | - |
| 1.005 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid | - | metre | 1,143.05 | - |
| 1.006 | OD118009/2026-2027:Supply and fixing ofSelf-adhesive vinyl sticker for lettering and figures of sizes and colour selected by the Engineer in charge for the identification mark to fan, AC, SB, DB, panel board , fire etc as required | - | sqm | 1,522.96 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1466920.xls
BOQ • 0.31 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Specificondtionsac-1.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].